All bodies  ›  Board of State and Community Corrections  ›  Orange County (2023-2024 inspection cycle)

BSCC

Orange County (2023-2024 inspection cycle)

Board of State and Community Corrections · inspection-059-3520-04-orange-james-a-musick-pre-opening-insp-rpt-2023-2024 · Facility inspection · 2024-09-26 · Orange County

Read the report at Orange County ↗

September 26, 2024 Don Barnes, Sheriff-Coroner Orange County Sheriff’s Department Central Justice Center 700 Civic Center Drive West Suite M-100 Santa Ana, CA 92701 COUNTY OF ORANGE: JAMES A. MUSICK FACILITY EXPANSION PROJECT BSCC PLAN REVIEW NUMBER: 059-3520.04 (AB 900 PII) and 059-3520.05 (SB 1022) Dear Sheriff Barnes, On July 30, 2024, the Board of State and Community Corrections (BSCC) staff met with Kevin Yang and other designated construction team members to conduct a pre-opening inspection of the James A. Musick Facility located at 13420 Alton Parkway, Irvine, California, for compliance with the applicable Minimum Standards for Local Detention Facilities as outlined in the 2010 Title 24, California Code of Regulations. The resulting inspection report is attached and is comprised of this letter, the Physical Plant Evaluation outlining the Title 24 requirements for the design, and a Living Area Space Evaluation that summarizes the facility’s configuration with a rated capacity of 896. This project meets Title 24 requirements and there are no areas of noncompliance. I have visited the construction site on several occasions and offered technical assistance and best practices to assist the construction team in resolving a prior compliance issue encountered during construction. I greatly appreciate the attention and effort of the staff in creating a safe and secure facility. If you have any questions or need further assistance, please do not hesitate to contact me by email at jill.farris@bscc.ca.gov or by phone at (916) 261-4325. Sincerely, JILL FARRIS Field Representative Facilities Standards & Operations Division Cc: Kevin Yang, Senior Architect, Facilities Planning Section ADULT TYPE I, II, III AND IV FACILITIES PHYSICAL PLANT EVALUATION The Board of State and Community Corrections APPLICABLE TITLE 24 REGULATIONS: 2010 BSCC Code: 3530 FACILITY NAME: James A. Musick Facility (JAMF) FACILITY TYPE: II APPLICABLE REGULATIONS: 2010 FIELD REPRESENTATIVE: Jill Farris DATE: July 30, 2024 TITLE 24 SECTION YES NO N/A COMMENTS 1231.2.1 RECEPTION AND BOOKING Weapons lockers are located in the Administrative area, staff entrance, and Facilities where booking and housing occur shall have outside the Intake Sallyport. ☒ ☐ ☐ the following space and equipment: 1. Weapons locker as specified in Section 1231.3.12. 2. A cell or room for the confinement of inmates pending their booking, complying with Section ☒ ☐ ☐ 1231.2.2. 3. A sobering cell as described in Section 1231.2.4 if intoxicated, inmates who may pose a danger to ☒ ☐ ☐ themselves or others are held. For those facilities that accept male and female intoxicated inmates two sobering cells shall be ☒ ☐ ☐ provided. 4. Access to a shower within the secure portion of ☒ ☐ ☐ the facility. 5. Provide access to a secure vault or storage ☒ ☐ ☐ space for inmate valuables. 1231.2.2 TEMPORARY HOLDING CELL OR ROOM ☒ ☐ ☐ A temporary holding cell or room shall: 1. Contain a minimum of 10 square feet (0.93 m2) of floor area per inmate; 2. Be limited to no more than 16 inmates; ☒ ☐ ☐ 3. Be no smaller than 40 square feet (3.7 m2) and have a clear ceiling height of 8 feet (2438 mm) or ☒ ☐ ☐ more; 4. Contain seating to accommodate all inmates as ☒ ☐ ☐ required in Section 1231.3; 5. Contain a toilet, wash basin and drinking ☒ ☐ ☐ fountain as specified in Section 1231.3; 6. Maximize visual supervision of inmates by staff; ☒ ☐ ☐ and 3530 Orange James A Musick Facility PHY 23-24 Page 1 of 10 A383 PHY Type I-IV (23-24).dot (rev.12/23) TITLE 24 SECTION YES NO N/A COMMENTS 7. When located in a temporary holding facility, the cell or room shall be equipped with a bunk if ☒ ☐ ☐ inmates are to be held longer than 12 hours. 1231.2.3 TEMPORARY STAGING CELL OR This facility does not have temporary staging ROOM cells (remainder of this regulation deleted). A temporary staging cell or room shall: ☐ ☐ ☒ 1. Be constructed for the purpose of holding inmates who have been classified and segregated in accordance with Sections 1050 and 1053 of Title 15, Division 1, California Code of Regulations. 1231.2.4 SOBERING CELL This facility has two sobering cells. A sobering cell shall: ☒ ☐ ☐ 1. Contain a minimum of 20 square feet (1.9 m2) of floor area per inmate; 2. Be limited to eight inmates; ☒ ☐ ☐ 3. Be no smaller than 60 square feet (5.6 m2) and have a clear ceiling height of 8 feet (2438 mm) or ☒ ☐ ☐ more; 4. Contain a toilet, wash basin and drinking ☒ ☐ ☐ fountain as specified in Section 1231.3; 5. Have padded partitions located next to toilet fixture in such a manner that they provide support ☒ ☐ ☐ to the user; 6. Maximize visual supervision of inmates by staff; ☒ ☐ ☐ 7. Be padded on the floor as specified in Section ☒ ☐ ☐ 1231.3; and, 8. Have accessible a shower in the secure portion ☒ ☐ ☐ of the facility. 1231.2.5 SAFETY CELL There is one safety cell. A safety cell shall: 1. Contain a minimum of 48 square feet (4.5 m2) of ☒ ☐ ☐ floor area with no one floor dimension being less than 6 feet (1829 mm) and a clear ceiling height of 8 feet (2438 mm) or more; 2. Be limited to one inmate; ☒ ☐ ☐ 3. Contain a flushing ring toilet, capable of accepting solid waste, mounted flush with the floor, ☒ ☐ ☐ the controls for which must be located outside of the cell; 4. Be padded as specified in Section 1231.3; ☒ ☐ ☐ 5. Be equipped with a variable intensity, security- type lighting fixture which is inaccessible to the ☒ ☐ ☐ inmate occupant, control of which is located outside of the cell; 3530 Orange James A Musick Facility PHY 23-24 Page 2 of 10 A383 PHY Type I-IV (23-24).dot (rev.12/23) TITLE 24 SECTION YES NO N/A COMMENTS 6. Provide one or more vertical view panels not more than 4 inches (102 mm) wide nor less than 24 ☒ ☐ ☐ inches (610 mm) long which shall provide a view of the entire room; 7. Provide a food pass with lockable shutter, no more than 4 inches (102 mm) high, and located between 26 inches (660 mm) and 32 inches (813 ☒ ☐ ☐ mm) as measured from the bottom of the food pass to the floor; and, 8. Any wall or ceiling mounted devices must be ☒ ☐ ☐ inaccessible to the inmate occupant. 1231.2.6 SINGLE-OCCUPANCY CELLS This facility does not have single occupancy cells (remainder of this regulation deleted). ☐ ☐ ☒ Single-occupancy cells shall: 1. Have a maximum capacity of one inmate; 1231.2.7 DOUBLE-OCCUPANCY CELLS This facility does not have double occupancy cells (remainder of this regulation deleted). ☐ ☐ ☒ Double-occupancy cells shall: 1. Have a maximum capacity of two inmates; 1231.2.8 DORMITORIES Dormitories shall: 1. Contain a minimum of 50 square feet (4.7 m2) of floor area per inmate for a single-bed unit; a ☒ ☐ ☐ minimum of 70 square feet (7 m2) for a double-bed unit; and a minimum of 90 square feet (9.3 m2) for triple-bed unit and have a minimum ceiling height of 8 feet (2438 mm); 2. Be designed for no more than 64 inmates and no ☒ ☐ ☐ fewer than four inmates; 3. Provide access to water closets separate from the wash basin and drinking fountains as specified ☒ ☐ ☐ in Section 1231.3; and 4. In other than Type I facilities, provide storage space for personal items and clothing for each ☒ ☐ ☐ occupant. 1231.2.9 DAYROOMS Dayrooms or dayroom space shall: ☒ ☐ ☐ 1. Contain 35 square feet (3.3 m2) of floor area per inmate in width in front of cells/rooms; 2. Contain tables and seating to accommodate the ☒ ☐ ☐ maximum number of inmates; 3. Provide access to water closets, wash basins and drinking fountains as specified in Section ☒ ☐ ☐ 1231.3; 4. Provide access to a shower or showers as ☒ ☐ ☐ specified in Section 1231.3; and 3530 Orange James A Musick Facility PHY 23-24 Page 3 of 10 A383 PHY Type I-IV (23-24).dot (rev.12/23) TITLE 24 SECTION YES NO N/A COMMENTS 5. Be provided to all inmates in Type II and Type III facilities (except those housed in special-use cells) and to inmate workers in Type I facilities. Dayroom space as described in this section may be a part of ☒ ☐ ☐ a single occupancy cell used for administrative segregation or a dormitory, in which case the floor area of the cell or a dormitory must be increased by the square footage required for the dayroom. 1231.2.10 EXERCISE AREA An outdoor exercise area or areas must be provided in every Type II and Type III facility. The minimum clear height must be 15 feet (4572 mm) and the minimum ☒ ☐ ☐ number of square feet of surface area will be computed by multiplying 80 percent of maximum rated population by 50 square feet (4.7 m2) and dividing the result by the number of one-hour exercise periods per day. The exercise area must contain or provide free access to a toilet, wash basin, and drinking fountain as ☒ ☐ ☐ provided in Section 1231.3. There must be at least one exercise area of not less than 600 square feet (55.7 m2). The design shall ☒ ☐ ☐ facilitate security and supervision appropriate to the level of custody. Type IV facilities shall have an outdoor recreation area ☒ ☐ ☐ or access to community recreation facilities. 1231.2.11 CORRECTIONAL PROGRAM/ MULTIPURPOSE SPACE An area for correctional programming must be provided ☒ ☐ ☐ in every Type II and Type III facility. The program area and furnishings shall be designed to meet the needs specified by the facility’s program statement. Type IV facilities shall have multipurpose space for games and activities, dining, visiting, TV meetings and ☐ ☐ ☒ quiet space for study and reading, such that activities do not conflict with each other. 1231.2.12 MEDICAL EXAMINATION ROOM There must be a minimum of one suitably equipped medical examination room in every facility which ☒ ☐ ☐ provides on-site health care. The examination room shall be designed in consultation with the responsible physician/health authority. Such a medical examination room shall: 1. Be located within the security area and provide ☒ ☐ ☐ for privacy of the inmates; 2. Provide not less than 100 square feet (9.3 m2) of floor space with no single dimension less than 7 ☒ ☐ ☐ feet (2134 mm); 3. Provide hot and cold running water; ☒ ☐ ☐ 4. Provide lockable storage for medical supplies; ☒ ☐ ☐ 3530 Orange James A Musick Facility PHY 23-24 Page 4 of 10 A383 PHY Type I-IV (23-24).dot (rev.12/23) TITLE 24 SECTION YES NO N/A COMMENTS 5. Provide an examination table; ☒ ☐ ☐ 6. Provide adequate lighting; and ☒ ☐ ☐ 7. Any room where medical procedures are provided must be equipped with hot and cold ☒ ☐ ☐ running water 1231.2.13 PHARMACEUTICAL STORAGE SPACE Provide lockable storage space for medical supplies ☒ ☐ ☐ and pharmaceutical preparations as referenced by Title 15, California Code of Regulations, Section 1216. 1231.2.14 MEDICAL CARE HOUSING This facility does not have medical care housing. ☐ ☐ ☒ There shall be some means to provide medical care and housing of ill and/or infirm inmates. When the program statement for a Type II or Type III facility indicates that medical care housing is needed, such housing must provide lockable storage space for ☐ ☐ ☒ medical instruments and must be located within the security area of the facility accessible to both female and male inmates, but not in the living area of either. The medical care housing unit shall be designed in ☐ ☐ ☒ consultation with the health authority. Medical/mental health areas may contain other than ☐ ☐ ☒ single occupancy cells. If negative pressure isolation rooms are being planned, they shall be designed to recognized industry ☐ ☐ ☒ standards. 1231.2.16 COMMISSARY In all Type II, III and IV facilities, except where community access is available, there shall be ☒ ☐ ☐ provisions made for inmates to purchase items (such as candy, toilet articles, stationery supplies, books, newspapers and magazines, etc.). An area shall be provided for the secure storage of the Commissary items will not be stored at this ☐ ☐ ☒ stock for such inmate canteen items. facility. 1231.2.17 DINING FACILITIES This facility does not have dining facilities. In all Type II, III and IV facilities which serve meals, ☐ ☐ ☒ dining areas shall be provided which will allow groups of inmates to dine together. Such dining areas shall not contain toilets, wash basins or showers in the same room without appropriate visual ☐ ☐ ☒ barrier. Wherever the facility contains a central dining room or rooms, it shall contain a minimum of 15 square feet (1.4 ☐ ☐ ☒ m2) of floor space and sufficient tables and seating for each inmate being fed. 3530 Orange James A Musick Facility PHY 23-24 Page 5 of 10 A383 PHY Type I-IV (23-24).dot (rev.12/23) TITLE 24 SECTION YES NO N/A COMMENTS 1231.2.18 VISITING SPACE This facility offers video visitation only (facility planned prior to 2017). ☐ ☐ ☒ Space shall be provided in all Types I, II, III and IV facilities for in-person visiting. 1231.2.19 SAFETY EQUIPMENT STORAGE A secure area shall be provided for the storage of ☒ ☐ ☐ safety equipment such as fire extinguishers, self- contained breathing apparatus, wire and barcutters, emergency lights, etc. 1231.2.20 JANITORS’ CLOSET In Type II facilities, at least one securely lockable ☒ ☐ ☐ janitors’ closet with sufficient area for the storage of cleaning implements and supplies must be provided within the security areas of the facility A mop sink shall also be available within the security area of the facility. In court holding, temporary holding, ☒ ☐ ☐ Types I, III and IV facilities, the closet need not be in the security area. 1231.2.21 STORAGE ROOMS One or more storage rooms shall be provided to accommodate a minimum of 80 cubic feet (2.3 m3) of storage area per inmate for inmate clothing and ☒ ☐ ☐ personal property, institutional clothing, bedding and supplies. Court holding, temporary holding and Type I facilities may be excluded from the storage space requirement for personal and institutional clothing unless clothing is issued. 1231.2.22 AUDIO MONITORING SYSTEM In court holding, temporary holding, Type I, Type II and Type II facilities there shall be an inmate- or sound- actuated audio monitoring system in temporary holding cells or rooms, temporary staging cells or rooms, ☒ ☐ ☐ sobering cells, safety cells, single and double occupancy cells, dormitories, dayrooms, exercise areas and correctional program/multipurpose space, which is capable of alerting personnel who can respond immediately. 1231.2.23 LAUNDRY FACILITIES Clothing is laundered at the old Musick facility. In Type IV facilities, provision shall be made for ☐ ☐ ☒ washing and drying personal clothing by machines, either in the facility or in the community, if access is permitted for same. 1231.2.24 EMERGENCY POWER There shall be a source of emergency power in all detention facilities capable of providing minimal lighting ☒ ☐ ☐ in all housing units, activities areas, corridors, stairs and central control points, and to maintain fire and life safety, security, communications and alarm systems. 3530 Orange James A Musick Facility PHY 23-24 Page 6 of 10 A383 PHY Type I-IV (23-24).dot (rev.12/23) TITLE 24 SECTION YES NO N/A COMMENTS Such an emergency power source shall conform to the requirements specified in Title 24, Part 3, Article 700, ☒ ☐ ☐ California Electrical Code, California Code of Regulations. 1231.2.25 CONFIDENTIAL INTERVIEW ROOMS There must be a minimum of one suitably furnished interview room for confidential interviews in every ☒ ☐ ☐ facility which provides onsite health care. The interview room shall be designed in consultation with responsible custodial staff and health care staff. Such an interview room shall: 1. Be located within the security area accessible to ☒ ☐ ☐ both female and male inmates; and 2. Provide not less than 70 square feet (6.5 m2) of floor space with no single dimension less than 6 ☒ ☐ ☐ feet (1829 mm). 1231.2.26 ATTORNEY INTERVIEW SPACE All facilities except Type IV facilities shall include ☒ ☐ ☐ attorney interview areas which provide for confidential consultation with inmates. 1231.3.1 TOILETS/URINALS ☒ ☐ ☐ 1. Toilets/urinals must be provided in single- occupancy cells and double-occupancy cells. 2. In dormitories, toilets/urinals must be provided in ☒ ☐ ☐ a ratio to inmates of 1:10. 3. Toilets/urinals must be accessible to the ☒ ☐ ☐ occupants of day-rooms and exercise areas. 4. In temporary holding cells and temporary staging cells toilets/urinals must be provided in a ratio to ☒ ☐ ☐ inmates of 1:16. 5. In sobering cells toilets/urinals must be provided ☒ ☐ ☐ in a ratio to inmates of 1:8. 6. One urinal or 2 feet (610 mm) of urinal trough may be substituted for each toilet up to one third of ☒ ☐ ☐ the total number of toilets required, except in those facilities or portions thereof used for females. 7. Toilet areas shall provide modesty for inmates ☒ ☐ ☐ with staff being able to visually supervise. 1231.3.2 WASH BASINS ☒ ☐ ☐ 1. Wash basins must be provided in single occupancy cells and double occupancy cells. 2. In dormitories, wash basins must be provided in ☒ ☐ ☐ a ratio to inmates of 1:10. 3. Wash basins must be accessible to the ☒ ☐ ☐ occupants of day-rooms and exercise areas 3530 Orange James A Musick Facility PHY 23-24 Page 7 of 10 A383 PHY Type I-IV (23-24).dot (rev.12/23) TITLE 24 SECTION YES NO N/A COMMENTS 4. In temporary holding cells and temporary staging cells, wash basins must be provided in a ratio to ☒ ☐ ☐ inmates of 1:16. 5. In sobering cells, wash basins must be provided ☒ ☐ ☐ in a ratio to inmates of 1:8. 6. Wash basins must be provided with hot and cold ☒ ☐ ☐ or tempered water. 7. Two feet (610 mm) of wash basin trough may be ☒ ☐ ☐ substituted for each basin required. 1231.3.3 DRINKING FOUNTAINS There must be a minimum of one drinking fountain in every single-occupancy cell, double-occupancy cell, ☒ ☐ ☐ dormitory, temporary holding cell, temporary staging cell, sobering cell, and be accessible to the occupants of day rooms and exercise areas. Additional drinking fountains shall be located in other areas of the facility so that drinking water will be ☒ ☐ ☐ available to inmates and staff. Such drinking fountains must meet the following minimum health requirements: 1. The drinking fountain bubbler shall be on an ☒ ☐ ☐ angle which prevents waste water from flowing over the drinking fountain bubbler. 2. Water flow shall be actuated by mechanical ☒ ☐ ☐ means. 1231.3.4 SHOWERS Must be available to all inmates on a ratio of at least ☒ ☐ ☐ one shower to every 20 inmates or fraction thereof and must provide hot and cold water or tempered water. Shower stalls/shower areas must be designed and constructed of materials which are impervious to water ☒ ☐ ☐ and soap so they may be easily cleaned. Shower areas shall provide modesty for inmates with ☒ ☐ ☐ staff being able to visually supervise. 1231.3.5 BEDS Must be elevated off the floor, have a solid bottom, and ☒ ☐ ☐ a sleeping surface of at least 30 inches (762 mm) wide and 76 inches (1930 mm) long. Multiple beds must have a minimum of 21 inches (533 ☒ ☐ ☐ mm) between bed pans. Except in minimum security areas, beds must be ☒ ☐ ☐ securely fastened to the floor or the wall. 3530 Orange James A Musick Facility PHY 23-24 Page 8 of 10 A383 PHY Type I-IV (23-24).dot (rev.12/23) TITLE 24 SECTION YES NO N/A COMMENTS 1231.3.6 LIGHTING Lighting in housing units, dayrooms and activity areas must be sufficient to permit easy reading by a person ☒ ☐ ☐ with normal vision, and shall not be less than 20 footcandles (215.2 lux) at desk level and in the grooming area. Lighting shall be centrally controlled and/or occupant ☒ ☐ ☐ controlled in housing cells or rooms. Night lighting in these areas shall be sufficient to give ☒ ☐ ☐ good visibility for purposes of supervision In minimum-security areas, lighting may be supplied by ordinary lighting fixtures, and in areas of higher ☒ ☐ ☐ security, light fixtures must be of secure design. 1231.3.7 WINDOWS In housing areas of higher than minimum security, exterior windows which are constantly accessible to ☒ ☐ ☐ inmates for escape must be designed and constructed so that if broken out, the net area accessible for escape is no greater than 5 inches (127 mm) in one dimension. 1231.3.8 CELL PADDING ☒ ☐ ☐ In sobering cells, the floor and partition shall be padded. In safety cells, padding must cover the entire floor, doors, and walls and everything on them to a clear ☒ ☐ ☐ height of 8 feet (2438 mm). All such padded cells must be equipped with a tamper resistant fire sprinkler as approved by the State Fire ☒ ☐ ☐ Marshal. All padding must be: 1. Approved for use by the State Fire Marshal; ☒ ☐ ☐ 2. Nonporous to facilitate cleaning; ☒ ☐ ☐ 3. At least 1/2-inch (12.7 mm) thick; ☒ ☐ ☐ 4. Of a unitary or laminated construction to prevent its destruction by teeth, hand tearing or small metal ☒ ☐ ☐ objects; 5. Firmly bonded to all padded surfaces to prevent ☒ ☐ ☐ tearing or ripping; and 6. Without any exposed seams susceptible to ☒ ☐ ☐ tearing or ripping. 1231.3.9 MIRRORS A mirror of a material appropriate to the level of security ☒ ☐ ☐ must be provided near each wash basin specified in these regulations. 3530 Orange James A Musick Facility PHY 23-24 Page 9 of 10 A383 PHY Type I-IV (23-24).dot (rev.12/23) TITLE 24 SECTION YES NO N/A COMMENTS 1231.3.10 SEATING ☒ ☐ ☐ In temporary holding and temporary staging cells, seating must be securely fixed to the floor and/or wall. When bench seating is used, 18 inches (457 mm) of ☒ ☐ ☐ bench is seating for one person. 1231.3.11 TABLE/SEAT This facility is dorm housing; however, there are tables/seats provided in the sleeping area. In single- and double-occupancy cells, a table and seat ☐ ☐ ☒ for the purpose of writing and dining shall be provided. Exception: A Type I facility does not require a table and a seat. 1231.3.12 WEAPONS LOCKER ☒ ☐ ☐ A secure weapons locker shall be located outside the security perimeter of the facility Such weapons lockers shall be equipped with individual compartments, each with an individual ☒ ☐ ☐ locking device. Weapons lockers are required in temporary and court holding facilities and in all facilities of higher than ☒ ☐ ☐ minimum security. 13-102(c)6 DESIGN REQUIREMENTS Design requirements as specified in Title 24, Part 1, 13- 102(c)6 are met. (See regulation for specific ☒ ☐ ☐ requirements. Note areas of non-compliance that are applicable to the facility type and construction date in the "comments" section.) 3530 Orange James A Musick Facility PHY 23-24 Page 10 of 10 A383 PHY Type I-IV (23-24).dot (rev.12/23) ADULT DETENTION FACILITY LIVING AREA SPACE EVALUATION Board of State and Community Corrections BSCC Code: 3530 FACILITY: James A. Musick Facility TYPE: II RC: 896 FIELD REPRESENTATIVE: Jill Farris DATE: July 30, 2024 ROOMS EACH ROOM EACH CELL FIXTURES* Cell Applicable # Total DIMENSIONS Location Type Standards Cells RC (L x W x H) # Beds RC T U W F S INTAKE – FEMALE HOLDING 1 Holding 2013 1 - (9) (9) 9’4” x 12’10”x 9’ 1 - 1 1 - Notes: Three benches: B1 6’ B2 4’4” B3 4’6” 2 Holding 2013 1 - (16) (16) 14’ x 12’10” x 9’ 1 - 1 1 - Notes: Six benches: B1 4’3” B2 6’ B3 4’3” B4 4’5” B5 6’ B6 10’ 3 Holding 2013 1 - (6) (6) 7’4” x 12’10” x 9’ 1 - 1 1 - Notes: Two benches: B1 4’3” B2 7’4” 4 Holding 2013 1 - (16) (16) 14’8” x 12’10” x 9’ 1 - 1 1 - Notes: Six benches: B1 4’4” B2 6’ B3 5’10” B4 3’6” B5 8’9” B6 3’4” 5 Holding 2013 1 - (6) (6) 7’4” x 12’10” x 9’ 1 - 1 1 - Notes: Two benches: B1 4’3” B2 7’5” 6 Holding 2013 1 - (16) (16) 14’8” x 12’10” x 9’ 1 - 1 1 - Notes: Six benches: B1 4’3” B2 6’1” B3 4’4” B4 6’8” B5 10’ B6 4’6” 7 Holding 2013 1 - (8) (8) 9’4” x 12’10”x 9’ 1 - 1 1 - Notes: B1 4’3” B2 6’ 8 Holding 2013 1 - (16) (16) 15’6” x 12’10” x 9’ 1 - 1 1 - Notes: B1 5’10” B2 3’8” B3 5’4” B4 4’9” B5 10’ B6 4’8” 9 Holding 2013 2 - (16) (16) 170 sq. ft. 1 - 1 1 - Notes: This cell has two sections 11’2” x 12’10” + 4’6” x 6’ B1 4’9” B2 11’4” B3 4’6” B4 5’10” B5 3’3” B6 4’9” Sobering Cell 2013 2 - (4) (4) 7’8” x 12’10” x 9’ 1 - 1 1 - Safety Cell 2013 1 (1) (1) 7’9” x 7’7” x 9’ 1 - - - - INTAKE – MALE HOLDING 1 Holding 2013 1 - (7) (7) 9’4” x 12’10” x 9’ 1 - 1 1 - Notes: Three benches, B1 4’ B2 4’4” B3 5’4” * T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit. If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 3530 Orange James A Musick Facility LASE 23-24 Page 1 of 10 A360 LASE Adult (23-24).dot (rev.12/23) ROOMS EACH ROOM EACH CELL FIXTURES* Cell Applicable # Total DIMENSIONS Location Type Standards Cells RC (L x W x H) # Beds RC T U W F S 2 Holding 2013 1 - (7) (7) 9’4” x 12’10” x 9’ 1 - 1 1 - Notes: Three benches, B1 4’ B2 4’4” B3 5’4” 3 Holding 2013 1 - (6) (6) 8’ x 12’10” x 9’ 1 - 1 1 - Notes: Two benches, B1 4’4” B2 7’5” 4 Holding 2013 1 - (6) (6) 8’ x 12’10” x 9’ 1 - 1 1 - Notes: Two benches, B1 4’4” B2 7’5” 5 Holding 2013 1 - (6) (6) 7’4” x 12’10” x 9’ 1 - 1 1 - Notes: Two benches, B1 4’4” B2 7’5” 6 Holding 2013 1 - (16) (16) 14’ x 12’10” x 9’ 1 - 1 1 - Notes: Five benches, B1 7’6” B2 3’6” B3 4’3” B4 6’ B5 5’6” 7 Holding 2013 1 - (15) (15) 14’1” x 12’10” x 9’ 1 - 1 1 - Notes: Five benches, B1 3’ B2 11’4” B3 4’3” B4 4’ B5 4’3” 8 Holding 2013 1 - (16) (16) 15’11”x12’10” x 9’ 1 - 1 1 - Notes: Five benches, B1 9’5” B2 4’6” B3 6’1” B4 4’ B5 4’4” ADA Cell 9 Holding 2013 1 - (5) (5) 7’4” x 12’10” x 9’ 1 - 1 1 - Notes: One bench measuring 8’8” 10 Holding 2013 1 - (16) (16) 17’10” x 8’4” x 9’ 1 - 1 1 - Notes: Irregular shaped cell with three benches, B1 9’10” B2 16’8” B3 3’6” Building C (Rated Capacity 384) Module A-1 1 Dorm 2013 1 8 9 8 25’8” x 13’6” x 8’6” 1 - 1 1 1 Notes: Notes: ADA Compliant, 346 sq ft – 12 sq ft (pillars) = 334 sq ft 2 Dorm 2013 1 8 8 8 23’10” x 12’10” x 8’6” 1 - 1 1 - Notes: 305 sq ft – 12 sq ft (pillars) = 293 sq ft 4 Dorm 2013 1 8 8 8 24’4” x 12’6” x 8’6” 1 - 1 1 - Notes: 304 sq ft – 21 sq ft (pillars) = 283 sq ft 6 Dorm 2013 1 8 8 8 23’6” x 12’10” x 8’6” 1 - 1 1 - Notes: 301 sq ft – 12 sq ft (pillars) = 289 sq ft 8 Dorm 2013 1 8 8 8 23’6” x 12’10” x 8’6” 1 - 1 1 - Notes: 301 sq ft – 12 sq ft (pillars) = 289 sq ft 10 Dorm 2013 1 8 8 8 25’8” x 13’6” x 8’6” 1 - 1 1 - Notes: 346 sq ft – 12 sq ft (pillars) = 334 sq ft * T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit. If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 3530 Orange James A Musick Facility LASE 23-24 Page 2 of 10 A360 LASE Adult (23-24).dot (rev.12/23) ROOMS EACH ROOM EACH CELL FIXTURES* Cell Applicable # Total DIMENSIONS Location Type Standards Cells RC (L x W x H) # Beds RC T U W F S Notes: There are two showers on the upper tier for Dorms 2-10. Module A-2 1 Dorm 2013 1 8 9 8 25’8” x 13’6” x 8’6” 1 - 1 1 1 Notes: ADA Compliant, 346 sq ft – 12 sq ft (pillars) = 334 sq ft 2 Dorm 2013 1 8 8 8 25’8” x 13’6” x 8’6” 1 - 1 1 - Notes: 346 sq ft – 12 sq ft (pillars) = 334 sq ft 23’6” x 12’10” x 8’6” 4 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: 301 sq ft – 12 sq ft (pillars) = 289 sq ft 6 Dorm 2013 1 8 8 8 23’6” x 12’10” x 8’6” 1 - 1 1 - Notes: 301 sq ft – 12 sq ft (pillars) = 289 sq ft 24’4” x 12’6” x 8’6” 8 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: 304 sq ft – 21 sq ft (pillars) = 283 sq ft 23’10” x 12’10” x 8’6” 10 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: 305 sq ft – 12 sq ft (pillars) = 293 sq ft Notes: There are two showers on the upper tier for Dorms 2-10 Module B-3 1 Dorm 2013 1 8 9 8 25’8” x 13’6” x 8’6” 1 - 1 1 1 Notes: Notes: ADA Compliant, 346 sq ft – 12 sq ft (pillars) = 334 sq ft 2 Dorm 2013 1 8 8 8 23’10” x 12’10” x 8’6” 1 - 1 1 - Notes: 305 sq ft – 12 sq ft (pillars) = 293 sq ft 4 Dorm 2013 1 8 8 8 24’4” x 12’6” x 8’6” 1 - 1 1 - Notes: 304 sq ft – 21 sq ft (pillars) = 283 sq ft 6 Dorm 2013 1 8 8 8 23’6” x 12’10” x 8’6” 1 - 1 1 - Notes: 301 sq ft – 12 sq ft (pillars) = 289 sq ft 8 Dorm 2013 1 8 8 8 23’6” x 12’10” x 8’6” 1 - 1 1 - Notes: 301 sq ft – 12 sq ft (pillars) = 289 sq ft 10 Dorm 2013 1 8 8 8 25’8” x 13’6” x 8’6” 1 - 1 1 - Notes: 346 sq ft – 12 sq ft (pillars) = 334 sq ft Notes: There are two showers on the upper tier for Dorms 2-10. Module B-4 1 Dorm 2013 1 8 9 8 25’8” x 13’6” x 8’6” 1 - 1 1 1 * T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit. If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 3530 Orange James A Musick Facility LASE 23-24 Page 3 of 10 A360 LASE Adult (23-24).dot (rev.12/23) ROOMS EACH ROOM EACH CELL FIXTURES* Cell Applicable # Total DIMENSIONS Location Type Standards Cells RC (L x W x H) # Beds RC T U W F S Notes: ADA Compliant, 346 sq ft – 12 sq ft (pillars) = 334 sq ft 2 Dorm 2013 1 8 8 8 25’8” x 13’6” x 8’6” 1 - 1 1 - Notes: 346 sq ft – 12 sq ft (pillars) = 334 sq ft 23’6” x 12’10” x 8’6” 4 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: 301 sq ft – 12 sq ft (pillars) = 289 sq ft 6 Dorm 2013 1 8 8 8 23’6” x 12’10” x 8’6” 1 - 1 1 - Notes: 301 sq ft – 12 sq ft (pillars) = 289 sq ft 24’4” x 12’6” x 8’6” 8 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: 304 sq ft – 21 sq ft (pillars) = 283 sq ft 23’10” x 12’10” x 8’6” 10 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: 305 sq ft – 12 sq ft (pillars) = 293 sq ft Notes: There are two showers on the upper tier for Dorms 2-10. Module C-5 1 Dorm 2013 1 8 9 8 25’8” x 13’6” x 8’6” 1 - 1 1 1 Notes: Notes: ADA Compliant, 346 sq ft – 12 sq ft (pillars) = 334 sq ft 2 Dorm 2013 1 8 8 8 23’10” x 12’10” x 8’6” 1 - 1 1 - Notes: 305 sq ft – 12 sq ft (pillars) = 293 sq ft 4 Dorm 2013 1 8 8 8 24’4” x 12’6” x 8’6” 1 - 1 1 - Notes: 304 sq ft – 21 sq ft (pillars) = 283 sq ft 6 Dorm 2013 1 8 8 8 23’6” x 12’10” x 8’6” 1 - 1 1 - Notes: 301 sq ft – 12 sq ft (pillars) = 289 sq ft 8 Dorm 2013 1 8 8 8 23’6” x 12’10” x 8’6” 1 - 1 1 - Notes: 301 sq ft – 12 sq ft (pillars) = 289 sq ft 10 Dorm 2013 1 8 8 8 25’8” x 13’6” x 8’6” 1 - 1 1 - Notes: 346 sq ft – 12 sq ft (pillars) = 334 sq ft Notes: There are two showers on the upper tier for Dorms 2-10. Module C-6 1 Dorm 2013 1 8 9 8 25’8” x 13’6” x 8’6” 1 - 1 1 1 Notes: ADA Compliant, 346 sq ft – 12 sq ft (pillars) = 334 sq ft 2 Dorm 2013 1 8 8 8 25’8” x 13’6” x 8’6” 1 - 1 1 - Notes: 346 sq ft – 12 sq ft (pillars) = 334 sq ft * T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit. If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 3530 Orange James A Musick Facility LASE 23-24 Page 4 of 10 A360 LASE Adult (23-24).dot (rev.12/23) ROOMS EACH ROOM EACH CELL FIXTURES* Cell Applicable # Total DIMENSIONS Location Type Standards Cells RC (L x W x H) # Beds RC T U W F S 23’6” x 12’10” x 8’6” 4 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: 301 sq ft – 12 sq ft (pillars) = 289 sq ft 6 Dorm 2013 1 8 8 8 23’6” x 12’10” x 8’6” 1 - 1 1 - Notes: 301 sq ft – 12 sq ft (pillars) = 289 sq ft 24’4” x 12’6” x 8’6” 8 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: 304 sq ft – 21 sq ft (pillars) = 283 sq ft 23’10” x 12’10” x 8’6” 10 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: 305 sq ft – 12 sq ft (pillars) = 293 sq ft Notes: There are two showers on the upper tier for Dorms 2-10 Module D-7 1 Dorm 2013 1 8 9 8 25’8” x 13’6” x 8’6” 1 - 1 1 1 Notes: Notes: ADA Compliant, 346 sq ft – 12 sq ft (pillars) = 334 sq ft 2 Dorm 2013 1 8 8 8 23’10” x 12’10” x 8’6” 1 - 1 1 - Notes: 305 sq ft – 12 sq ft (pillars) = 293 sq ft 4 Dorm 2013 1 8 8 8 24’4” x 12’6” x 8’6” 1 - 1 1 - Notes: 304 sq ft – 21 sq ft (pillars) = 283 sq ft 6 Dorm 2013 1 8 8 8 23’6” x 12’10” x 8’6” 1 - 1 1 - Notes: 301 sq ft – 12 sq ft (pillars) = 289 sq ft 8 Dorm 2013 1 8 8 8 23’6” x 12’10” x 8’6” 1 - 1 1 - Notes: 301 sq ft – 12 sq ft (pillars) = 289 sq ft 10 Dorm 2013 1 8 8 8 25’8” x 13’6” x 8’6” 1 - 1 1 - Notes: 346 sq ft – 12 sq ft (pillars) = 334 sq ft Notes: There are two showers on the upper tier for Dorms 2-10. Module D-8 1 Dorm 2013 1 8 9 8 25’8” x 13’6” x 8’6” 1 - 1 1 1 Notes: ADA Compliant, 346 sq ft – 12 sq ft (pillars) = 334 sq ft 2 Dorm 2013 1 8 8 8 25’8” x 13’6” x 8’6” 1 - 1 1 - Notes: 346 sq ft – 12 sq ft (pillars) = 334 sq ft 23’6” x 12’10” x 8’6” 4 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: 301 sq ft – 12 sq ft (pillars) = 289 sq ft * T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit. If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 3530 Orange James A Musick Facility LASE 23-24 Page 5 of 10 A360 LASE Adult (23-24).dot (rev.12/23) ROOMS EACH ROOM EACH CELL FIXTURES* Cell Applicable # Total DIMENSIONS Location Type Standards Cells RC (L x W x H) # Beds RC T U W F S 6 Dorm 2013 1 8 8 8 23’6” x 12’10” x 8’6” 1 - 1 1 - Notes: 301 sq ft – 12 sq ft (pillars) = 289 sq ft 24’4” x 12’6” x 8’6” 8 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: 304 sq ft – 21 sq ft (pillars) = 283 sq ft 23’10” x 12’10” x 8’6” 10 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: 305 sq ft – 12 sq ft (pillars) = 293 sq ft Notes: There are two showers on the upper tier for Dorms 2-10. Building B (Rated Capacity 512) ∗ Lower-Level Odd Numbers Two showers available ∗ Upper-Level Even Numbers Two showers available Module E-9 1 Dorm 2013 1 8 8 8 23’11” x 13’4” x 8’6” 1 - 1 1 - Notes: 318 sq ft – 12 sq ft (pillars) = 306 sq ft 3 Dorm 2013 1 8 8 8 23’11” x 13’4” x 8’6” 1 - 1 1 - Notes: 318 sq ft – 12 sq ft (pillars) = 306 sq ft 5 Dorm 2013 1 8 8 8 25’3” x 14’ x 8’6” 1 - 1 1 - Notes: 353 sq ft – 12 sq ft (pillars) = 341 sq ft 24’1” x 12’11” x 8’6” 2 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: 311 sq ft – 12 sq ft (pillars) = 299 sq ft 25’3” x 12’11” x 8’6” 4 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: 326 sq ft – 6 sq ft (pillar) = 320 sq ft 6 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 322 sq ft – 6 sq ft (pillar) = 316 sq ft 8 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 322 sq ft – 6 sq ft (pillar) = 316 sq ft 10 Dorm 2013 1 8 8 8 25’3” x 14’ x 8’6” 1 - 1 1 - Notes: 353 sq ft – 12 sq ft (pillars) = 341 sq ft Module E-10 1 Dorm 2013 1 8 8 8 25’3” x 14’ x 8’6” 1 - 1 1 - Notes: * T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit. If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 3530 Orange James A Musick Facility LASE 23-24 Page 6 of 10 A360 LASE Adult (23-24).dot (rev.12/23) ROOMS EACH ROOM EACH CELL FIXTURES* Cell Applicable # Total DIMENSIONS Location Type Standards Cells RC (L x W x H) # Beds RC T U W F S 3 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 5 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 2 Dorm 2013 1 8 8 8 25’3” x 14’ x 8’6” 1 - 1 1 - Notes: 4 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 6 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 25’3” x 12’11” x 8’6” 8 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: 24’1” x 12’11” x 8’6” 10 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: Module F-11 1 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 3 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 5 Dorm 2013 1 8 8 8 25’3” x 14’ x 8’6” 1 - 1 1 - Notes: 24’1” x 12’11” x 8’6” 2 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: 25’3” x 12’11” x 8’6” 4 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: 6 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 8 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: * T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit. If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 3530 Orange James A Musick Facility LASE 23-24 Page 7 of 10 A360 LASE Adult (23-24).dot (rev.12/23) ROOMS EACH ROOM EACH CELL FIXTURES* Cell Applicable # Total DIMENSIONS Location Type Standards Cells RC (L x W x H) # Beds RC T U W F S 10 Dorm 2013 1 8 8 8 25’3” x 14’ x 8’6” 1 - 1 1 - Notes: Module F-12 1 Dorm 2013 1 8 8 8 25’3” x 14’ x 8’6” 1 - 1 1 - Notes: 3 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 5 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 2 Dorm 2013 1 8 8 8 25’3” x 14’ x 8’6” 1 - 1 1 - Notes: 4 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 6 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 25’3” x 12’11” x 8’6” 8 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: 24’1” x 12’11” x 8’6” 10 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: Module G-13 1 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 3 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 5 Dorm 2013 1 8 8 8 25’3” x 14’ x 8’6” 1 - 1 1 - Notes: 24’1” x 12’11” x 8’6” 2 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: 25’3” x 12’11” x 8’6” 4 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular * T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit. If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 3530 Orange James A Musick Facility LASE 23-24 Page 8 of 10 A360 LASE Adult (23-24).dot (rev.12/23) ROOMS EACH ROOM EACH CELL FIXTURES* Cell Applicable # Total DIMENSIONS Location Type Standards Cells RC (L x W x H) # Beds RC T U W F S Notes: 6 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 8 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 10 Dorm 2013 1 8 8 8 25’3” x 14’ x 8’6” 1 - 1 1 - Notes: Module G-14 1 Dorm 2013 1 8 8 8 25’3” x 14’ x 8’6” 1 - 1 1 - Notes: 3 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 5 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 2 Dorm 2013 1 8 8 8 25’3” x 14’ x 8’6” 1 - 1 1 - Notes: 4 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 6 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 25’3” x 12’11” x 8’6” 8 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: 24’1” x 12’11” x 8’6” 10 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: Module H-15 1 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 3 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 5 Dorm 2013 1 8 8 8 25’3” x 14’ x 8’6” 1 - 1 1 - * T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit. If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 3530 Orange James A Musick Facility LASE 23-24 Page 9 of 10 A360 LASE Adult (23-24).dot (rev.12/23) ROOMS EACH ROOM EACH CELL FIXTURES* Cell Applicable # Total DIMENSIONS Location Type Standards Cells RC (L x W x H) # Beds RC T U W F S Notes: 24’1” x 12’11” x 8’6” 2 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: 25’3” x 12’11” x 8’6” 4 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: 6 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 8 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 10 Dorm 2013 1 8 8 8 25’3” x 14’ x 8’6” 1 - 1 1 - Notes: Module H-16 1 Dorm 2013 1 8 8 8 25’3” x 14’ x 8’6” 1 - 1 1 - Notes: 3 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 5 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 2 Dorm 2013 1 8 8 8 25’3” x 14’ x 8’6” 1 - 1 1 - Notes: 4 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 6 Dorm 2013 1 8 8 8 24’ x 13’5” x 8’6” 1 - 1 1 - Notes: 25’3” x 12’11” x 8’6” 8 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: 24’1” x 12’11” x 8’6” 10 Dorm 2013 1 8 8 8 1 - 1 1 - Irregular Notes: * T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit. If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 3530 Orange James A Musick Facility LASE 23-24 Page 10 of 10 A360 LASE Adult (23-24).dot (rev.12/23)