BSCC
Fresno County, Selma Police Pre-Opening (2020-2022 inspection cycle)
Read the report at Fresno County, Selma Police Pre-Opening ↗
December 15, 2020
Joseph Gomez, Chief of Police
Selma Police Department
2055 Third Street
Selma, Ca 93662
County of Fresno – City of Selma Police Department Temporary Holding Facility - BSCC Plan
Review Number 019-0801.01
Dear Chief Gomez:
On December 02, 2020, BSCC staff conducted a pre-opening inspection of the newly constructed
Selma Police Department Temporary Holding Facility. The purpose of this inspection was to
determine compliance with the applicable Minimum Standards for Temporary Holding Facilities
as outlined in Titles 15 and 24, California Code of Regulations (CCR). The Title 24, 2013
Regulations were applied as these regulations were in effect at the time the original Letter of
Intent to begin the construction process was received.
The inspection report includes this letter, a Physical Plant Evaluation outlining Title 24
requirements for the facility design and furnishings and a Living Area Space Evaluation that
summarizes the facility’s configuration and rated capacity. We encourage the practice of
maintaining a permanent file for historical copies of all inspections and this file should be the first
point of reference when preparing for all future inspections.
There are no issues of non-compliance noted.
We would like to acknowledge the efforts of everyone with whom we have interacted during the
entire planning and construction process. The result is the culmination of their efforts in
successfully constructing a facility that will serve the needs of your community for many years.
This concludes the pre-opening inspection report. We very much appreciate your commitment
to operate safe and secure detention facilities in compliance with the California Code of
Regulations. Should you have any questions or comments relating to this inspection, please
contact me directly, at (916) 956-1559 or by e-mail at tim.mcwilliams@bscc.ca.gov.
Sincerely,
Tim McWilliams
Field Representative
Facilities, Standards and Operations Division
cc: J. Cerda, Sergeant
R. Garza, Facility Commander
Andres Enciso, Vanir Construction
Michael Bush, Field Representative BSCC
0801 Fresno Co. Selma PD THJ Pre-Opening LTR 12.15.2020
ADULT COURT AND TEMPORARY HOLDING FACILITIES
PHYSICAL PLANT EVALUATION
The Board of State and Community Corrections
APPLICABLE TITLE 24 REGULATIONS: 2013
BSCC Code:0801
FACILITY NAME: Fresno County, Selma Police Department FACILITY TYPE: THJ
6/94: ☐ 2/99: ☐ 2001: ☐ 2005: ☐ 2008: ☐ 2010: ☐
APPLICABLE REGULATIONS (Check All That Apply):
2013: ☒ 2017: ☐ ☐ ☐ ☐
FIELD REPRESENTATIVE: Tim McWilliams DATE: December 02, 2020
TITLE 24 SECTION YES NO N/A COMMENTS
The design of court holding and temporary holding facilities shall include the following required spaces from Sections 1231.2.2, 1231.2.19,
1231.2.20, 1231.2.21, 1231.2.22, 1231.2.24 and 1231.2.26.
1231.2.2 Temporary holding cell or room.
A temporary holding cell or room shall:
☒ ☐ ☐
1. Contain a minimum of 10 square feet (0.93 m2) of
floor area per inmate;
2. Be limited to no more than 16 inmates; ☒ ☐ ☐
3. Be no smaller than 40 square feet (3.7 m2) and have a
☒ ☐ ☐
clear ceiling height of 8 feet (2438 mm) or more;
4. Contain seating to accommodate all inmates as
☒ ☐ ☐
required in Section 1231.3;
5. Contain a toilet, wash basin and drinking fountain as
☒ ☐ ☐
specified in Section 1231.3;
6. Maximize visual supervision of inmates by staff; and ☒ ☐ ☐
7. When located in a temporary holding facility, the cell Inmates are not held longer than 12 hours.
or room shall be equipped with a bunk if inmates are to ☐ ☐ ☒
be held longer than 12 hours.
1231.2.19 Safety equipment storage. Secure safety equipment storage area located in
A secure area shall be provided for the storage of safety Booking Processing room.
equipment such as fire extinguishers, self-contained ☒ ☐ ☐
breathing apparatus, wire and barcutters, emergency lights,
etc..
1231.2.20 Janitors’ closet. Janitors closet located next to Cell 1.
In Type II facilities, at least one securely lockable janitors’
closet with sufficient area for the storage of cleaning ☒ ☐ ☐
implements and supplies must be provided within the
security areas of the facility
A mop sink shall also be available within the security area of
the facility. In court holding, temporary holding, Types I, III
and IV facilities, the closet need not be in the security area.
☒ ☐ ☐
0801 Fresno Selma THJ PHY 20-22 - 1 - A383 PHY Type I-IV 94 99 01 05 08 10 13 17.dot (1/19)
TITLE 24 SECTION YES NO N/A COMMENTS
1231.2.21 Storage rooms.
One or more storage rooms shall be provided to
accommodate a minimum of 80 cubic feet (2.3 m3) of storage
area per inmate for inmate clothing and personal property,
☐ ☐ ☒
institutional clothing, bedding and supplies. Court holding,
temporary holding and Type I facilities may be excluded
from the storage space requirement for personal and
institutional clothing unless clothing is issued.
1231.2.22 Audio monitoring system.
In court holding, temporary holding, Type I, Type II and
Type II facilities there shall be an inmate- or sound-actuated
audio monitoring system in temporary holding cells or
rooms, temporary staging cells or rooms, sobering cells, ☒ ☐ ☐
safety cells, single and double occupancy cells, dormitories,
dayrooms, exercise areas and correctional
program/multipurpose space, which is capable of alerting
personnel who can respond immediately.
1231.2.24 Emergency power.
There shall be a source of emergency power in all detention
facilities capable of providing minimal lighting in all housing
☒ ☐ ☐
units, activities areas, corridors, stairs and central control
points, and to maintain fire and life safety, security,
communications and alarm systems.
Such an emergency power source shall conform to the
requirements specified in Title 24, Part 3, Article 700, ☒ ☐ ☐
California Electrical Code, California Code of Regulations.
1231.2.26 Attorney interview space. Located in jail release area or can be
All facilities except Type IV facilities shall include attorney accommodated in booking processing room.
☒ ☐ ☐
interview areas which provide for confidential consultation
with inmates.
1231.3.1 Toilets/urinals.
In temporary holding cells and temporary staging cells
☒ ☐ ☐
toilets/urinals must be provided in a ratio to inmates of 1:16.
One urinal or 2 feet (610 mm) of urinal trough may be
substituted for each toilet up to one third of the total number
☐ ☐ ☒
of toilets required, except in those facilities or portions
thereof used for females.
Toilet areas shall provide modesty for inmates with staff
☒ ☐ ☐
being able to visually supervise.
1231.3.2 Wash basins.
In temporary holding cells and temporary staging cells, wash
☒ ☐ ☐
basins must be provided in a ratio to inmates of 1:16.
Wash basins must be provided with hot and cold or tempered Hot and cold water in cells.
☒ ☐ ☐
water.
Two feet (610 mm) of wash basin trough may be substituted
☐ ☐ ☒
for each basin required.
1231.3.3 Drinking fountains. Each holding cell has a drinking fountain.
There must be a minimum of one drinking fountain in every
single-occupancy cell, double-occupancy cell, dormitory,
☒ ☐ ☐
temporary holding cell, temporary staging cell, sobering cell,
and be accessible to the occupants of day rooms and exercise
areas.
Additional drinking fountains shall be located in other areas Staff can also provide cups of water upon request.
of the facility so that drinking water will be available to ☒ ☐ ☐
inmates and staff.
0801 Fresno Selma THJ PHY 20-22 - 2 - A383 PHY Type I-IV 94 99 01 05 08 10 13 17.dot (1/19)
TITLE 24 SECTION YES NO N/A COMMENTS
Such drinking fountains must meet the following minimum
health requirements:
1. The drinking fountain bubbler shall be on an angle ☒ ☐ ☐
which prevents waste water from flowing over the
drinking fountain bubbler.
2. Water flow shall be actuated by mechanical means. ☒ ☐ ☐
1231.3.6 Lighting.
Lighting in housing units, dayrooms and activity areas must
be sufficient to permit easy reading by a person with normal ☒ ☐ ☐
vision, and shall not be less than 20 footcandles (215.2 lux)
at desk level and in the grooming area.
Lighting shall be centrally controlled and/or occupant Centrally controlled.
☒ ☐ ☐
controlled in housing cells or rooms.
Night lighting in these areas shall be sufficient to give good
☒ ☐ ☐
visibility for purposes of supervision
In minimum-security areas, lighting may be supplied by
ordinary lighting fixtures, and in areas of higher security, ☐ ☐ ☒
light fixtures must be of secure design.
1231.3.10 Seating.
In temporary holding and temporary staging cells, seating ☒ ☐ ☐
must be securely fixed to the floor and/or wall.
When bench seating is used, 18 inches (457 mm) of bench is
☒ ☐ ☐
seating for one person.
1231.3.12 Weapons locker. Located outside in vehicle sally port and inside
A secure weapons locker shall be located outside the security ☒ ☐ ☐ building, just outside security area.
perimeter of the facility
Such weapons lockers shall be equipped with individual
☒ ☐ ☐
compartments, each with an individual locking device.
Weapons lockers are required in temporary and court holding
☒ ☐ ☐
facilities and in all facilities of higher than minimum security.
Design Requirements (102(c)6)
Design requirements as specified in Title 24, Part 1, 102(c)6
are met. (See regulation for specific requirements. Note ☒ ☐ ☐
areas of non-compliance that are applicable to the facility
type and construction date in the "comments" section.)
0801 Fresno Selma THJ PHY 20-22 - 3 - A383 PHY Type I-IV 94 99 01 05 08 10 13 17.dot (1/19)
ADULT DETENTION FACILITY
LIVING AREA SPACE EVALUATION
Board of State and Community Corrections
BSCC Code: 801
FACILITY: Fresno County, Selma Police Department TYPE: THJ RC: (11)
FIELD REPRESENTATIVE: Tim McWilliams DATE: December 02, 2020
ROOMS EACH ROOM
Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES*
Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S
A securable booking processing room is in the intake area which includes a 4’ bench. A toilet, washbasin, and shower room are also located
in the intake area.
Cell 1 Sobering 2013 1 3 (3) 8’x7’8”x9’ 1 1 1
Padded floor
Cell 2 Holding 2013 1 2 (2) 5’9x7’8”x9’ 1 1 1
4’x18” metal bench. Capacity limited by length of bench.
Cell 3 Holding 2013 1 2 (2) 1 1 1
ADA compliant cell. 4’x24” metal bench. Capacity limited by length of bench.
Cell 4 Juvenile 2013 1 2 (2) 7’1”x6’6”x9 1 1 1
Holding
4’x18” metal bench. Capacity limited by length of bench.
Cell 5 Juvenile 2013 1 2 (2) 6’5”x12’2”x9’ 1 1 1
Holding
ADA compliant cell. 4’x24” metal bench. Capacity limited by length of bench.
*T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit. If "Total RC" appears in brackets ( ), it is not part of
the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas.
0801 Fresno Selma THY LAS 20-22 - 1 - A360 LAS Adult-05.dot (8/05)