All bodies  ›  Board of State and Community Corrections  ›  Santa Clara County, Detention Facilities (2016-2018 inspection cycle)

BSCC

Santa Clara County, Detention Facilities (2016-2018 inspection cycle)

Board of State and Community Corrections · inspection-santa-clara-county-detention-facilities-2016-2018 · Facility inspection · 2018-07-18 · Santa Clara County, Detention Facilities

Read the report at Santa Clara County, Detention Facilities ↗

July 18, 2018 Laurie Smith, Sheriff Santa Clara County Office of the Sheriff 55 West Younger Avenue San Jose, CA 95110-1721 2016-2018 BIENNIAL INSPECTION – PENAL CODE SECTION 6031 Dear Sheriff Smith: On February 26 through March 6, 2018, the Board of State and Community Corrections (BSCC) conducted the biennial inspection of the Santa Clara Detention Facilities. To prepare staff for the inspection, a pre-inspection briefing was held on December 10, 2017. Detention Facility BSCC # Courthouse Facility BSCC # Main Jail 5120 Hall of Justice 5206 Elmwood (Men) 5140 Family Justice Center 5200 Elmwood (Female) 5180 South County 5208 Scope of Inspection The inspection was preceded by a desk audit of the Corrections Division’s Policy and Procedures Manual along with applicable post orders governing the operation of each facility. The inspection assessed compliance with adult regulations in Titles 15 and 24, Minimum Standards for Local Detention Facilities, California Code of Regulations (CCR). It consisted of a “walk-through” of each physical plant, review of policies and procedures governing operations, and staff/inmate interviews. Additionally, we met with health care, inmate program and food services administrators and managers. As in past inspections, we interviewed custody administrators, managers, supervisory and line staff associated with the facilities. We also interviewed inmates to ensure they have the opportunity to receive programs afforded to them. We want to express our appreciation to Captain Eric Taylor, Lieutenants Patrick Corso and James Jensen, Sergeants Arthur Candelaria and Victoria Solis, Deputies Allegra Aponte, Brett Bernal and Robert Mickanen for their support and availability throughout the inspections. Your agency was well prepared with information and documentation was readily available in anticipation of any questions or concerns we had. 5120 + SCSD DOC LTR; 07/18/2018 Laurie Smith, Sheriff 2 | P age The complete BSCC inspection report is enclosed and consists of: this transmittal letter; the “Inspection Information Worksheet”; Consolidated “Procedures Checklist” for the facilities outlining applicable Title 15 sections; “Physical Plant Evaluations” outlining Title 24 requirements for design1 for each facility and, A “Living Area Space Evaluations” summarizing each facility’s physical plant configurations. Local Inspections: In addition to a biennial inspection by the BSCC, inspections are also required annually by the County Health Officer and biennially by the State Fire Marshal or an authorized representative (Health and Safety Code Sections 101045 and 13146.1). Fire Inspection Detention Facility BSCC # Fire Inspection Date Fire Clearance Granted Main Jail 5120 06/20/2012 overdue Elmwood (Men) 5140 09/07/2017 Yes Elmwood (Female) 5180 09/17/2017 Yes Court Holding Facility BSCC # Fire Inspection Date Fire Clearance Granted Hall of Justice 5206 04/28/04 Please forward fire report when it becomes available. Family Justice Center 5200 09/21/2017 Pending please advise when corrections have been made. South County 5208 07/27/2017 Pending please advise when corrections have been made Health Inspection The following table lists the dates of the health inspections for each detention facility. The following abbreviations were used in the table: EH (environmental health), MMH (medical/mental health) and NH (nutritional health). Detention Facility EH Inspection MMH Inspection NH Inspection Main Jail 06/20/2017 06/20/2017 06/20/2017 Elmwood (Men) 09/19/2017 09/19/2017 09/19/2017 Elmwood (Female) 09/20/2017 09/20/2017 09/20/2017 Court Holding Facility EH Inspection MMH Inspection NH Inspection Hall of Justice 10/19/2016 10/19/2016 N/A Family Justice Center 10/19/2016 10/19/2016 N/A South County 09/26/2016 09/26/2016 N/A 1 Facilities are assessed against Title 24 requirements in place at the time of design or significant remodel to the jail area. 5120 + SCSD DOC LTR; 07/18/2018 Laurie Smith, Sheriff 3 | P age Please consider our report in conjunction with the reports from the County Health Officer and the Fire Authority for a comprehensive perspective of your facility. BSCC Inspection: Title 15, CCR; Policy, Procedures & Practice System Wide This report addresses compliance issues with Title 15 and 24, California Code of Regulations (CCR) for the Santa Clara County Sheriff’s Department. This report will address the detention facilities in one section of the report and the Court Services Division in a separate heading. I will be addressing my observations and documentations for each facility which led to non-compliance for a specific Title 15 and 24 CCR as required by 6031.1. PC. Title 15, CCR; Policy and Procedures: All three facilities operate as a system; therefore, policies and procedures reviewed are applicable to each. Staff members are constantly in the process of reviewing and revising policies. We informed your staff that there is a recently updated version of Title 15 Minimum Standards and that the facility should go through the new standards to ensure that the facility will remain in compliance with their policy and procedures manual. Please review the enclosed policy and procedures checklist. As mentioned above, a desk audit of the Corrections Division’s Policy and Procedures Manual was conducted prior to the on-site inspection. On-site BSCC continued its inspection by evaluating procedures at the facility and comparing them against policy. Those evaluations include a review of documentation related to jail operations including security logs, shift schedules, local inspection results, classification/housing assignments, incident reports, disciplinary actions, grievance actions and other records which give insight to the facility’s operations. When applicable, special attention was given to those low-incidence but high-liability practices involving inebriated inmates, high-risk inmates and use of restraints and safety cells placement. BSCC sought to ensure that practices matched regulations and that written documents reflected actual events. BSCC interviewed staff to ensure that documented procedures were being performed according to policy. All documents reviewed were completed and well organized. We found no issues of non-compliance. Staffing: One key determination to be made during the inspection process is the adequacy of staffing. Title 15 Section 1027 requires each facility to maintain adequate on-duty staff to ensure the implementation of all programs and activities as required by regulation. Supervision of arrestees is the responsibility of correctional officers, supervised generally by a facility Manager. BSCC reviewed security check logs, incident reports and arrestee files to ensure that all required tasks were completed in a timely and safe manner. We found no issues of non-compliance. Medical/Mental Health Services: Medical care is provided by the Santa Clara Valley Medical Center to the inmates from the time of booking through release. All inmates are medically screened upon arrival and evaluated for medical and mental health conditions which could require continued care and treatment. Health professionals are on duty 24/7 5120 + SCSD DOC LTR; 07/18/2018 Laurie Smith, Sheriff 4 | P age and provide a full range of services including daily physician sick call, medication administration, treatments, dialysis, radiology services, dental care and psychiatric care. Physical Plant Inspections Santa Clara County Main Jail: Sergeant Arthur Candelaria and Deputies Allegra Aponte and Brett Bernal accompanied us during our site inspection. The Main Jail was evaluated as a Type II Facility under the 1963, 1980, and 1988 Standards that were in effect at the time of the original construction and when various areas were remodeled or added to the facility. With the completion of the current renovation project on living units 4A and 5A the Rated Capacity (RC) was decreased from 1356 to 1350. The facility has eight floors and utilizes “direct supervision” inmate management. Each living unit is supervised by one, two or three custody staff depending on the classification of the unit. The infirmary, which is located on the second floor, is staffed by nurses and doctors employed through the Valley Medical Center as well as custody staff. Additionally the jail houses acute mental health inmates, on the eighth floor, which is staffed with specially trained officers and Valley Medical Center staff. The Main Jail South facility’s recreation/exercise area (Sundeck) was remodeled (modified) by constructing an enclosed recreation yard inside the original recreation yard. These enclosures allow housing units flexibility to have more maximum-security inmates participate in recreation at the same time, in order to meet and satisfy Title 15, Section 1065, Exercise and Recreation. The recreation enclosure space is adequate to allow inmates to run, perform large muscle exercises and throw/bounce a ball. The “Living Area Space Evaluation” has been updated on numerous occasions to reflect changes throughout the years. The facility has a BSCC rated capacity of 1356 with 1549 actual beds. There were 768 males and 5 females in custody on the day of the inspection. The facility as a whole was clean and appeared well maintained. The old South Jail was half empty in anticipation of being torn down and replaced. The new construction will begin later this year. The physical plant complies with applicable standards with the following exceptions: 1231.2.2, Temporary Holding Cells: Each holding cell has a RC, which is based on the size of the cells and the bench space. The maximum number of inmates in any holding cell cannot go over 16. On the day of the inspection there were 26 inmates in the holding cell T4. Elmwood Complex – Men’s Facility: Sergeant Solis and Deputy Mickanen accompanied us during our site inspection. This facility was evaluated as a Type II Facility under the 1963, 1980, and 1991 standards that were in effect at the time of original construction, and when various areas were remodeled or added to the facility. As with the main jail, the “Living Area Space Evaluation” continues to be a work in progress. The facility continues to remodel, renovate and close several living areas. Barracks 11, 12, 15-21 were closed. The Rated Capacity was increased from 2176 with an overall 2989 beds available. On the date of the inspection, there were 2048 inmates in custody. The following non-compliance issue was noted: 1231.2.8 Dormitories contain a minimum of floor area per inmate for a double-bed unit: • M2 (A) rated for 50, day of inspection 52 5120 + SCSD DOC LTR; 07/18/2018 Laurie Smith, Sheriff 5 | P age • M8 (A) rated for 56, day of inspection 65 • M8 (D) rated for 60, day of inspection 61 Elmwood Complex – Women’s Facility: Sergeant Victoria Solis and Deputy Robert Mickanen accompanied us during our site inspection. This facility was evaluated as a Type II Facility under the 1963, 1980, and 1986 standards that were in effect at the time of the original construction and when various areas were remodeled or added to the facility. The rated capacity is 634; however, there are 720 beds available. The total count of inmates the day of the inspection was 411. The physical plant complies with applicable standards. Court Security Services Division Inspections Prior to the on-site portion of the inspection we reviewed relevant policy and procedures and supporting documentation where necessary. The Court Holding facilities have a consolidated manual applicable to all facilities. Post orders, specifically designed for the various facilities, provide guidance to staff at those facilities. There were no items of noncompliance with Title 15. Please refer to the Procedures Checklist for further comments/discussion. Lieutenant James Jensen escorted BSCC to each facility as we conducted the physical plant evaluation. During the on-site portion of the inspections, we compared the manuals against the practices of staff at each facility. Staff we interviewed were well prepared and engaged in the inspection process. We also reviewed samples of safety checks logs, inmate records, classification records, and incident reports, among other documentation. All forms were complete and conformed with the department’s policies and procedures including operational requirements as set forth in Title 15. Hall of Justice: Completed in 1991, the Hall of Justice Court Holding is evaluated using 1980 physical plant standards in place at the time of original construction. No issues of non-compliance with Title 24 standards were identified. Juveniles who are attending adult court will be held in a holding cell in the basement detention area. The Sheriff’s deputies ensure separation between adults and juveniles. We reiterated the federal and state laws and regulations regarding separation of adults and minors. Family Justice Center: The new Family Justice Center Courthouse opened to the public on August 15, 2016. The facility is evaluated using 2010 physical plant standards. At the time of the inspection there were 33 inmates in custody. No issues of non-compliance with Title 24 standards were identified. Juveniles who are attending adult court will be held in the juvenile holding area, separate from adult prisoners. The Sheriff’s deputies ensure separation between adults and juveniles. South County Courthouse: The facility is evaluated using 2001 physical plant standards. At the time of the inspection there were 23 inmates in custody. No issues of non-compliance with Title 24 standards were identified. 5120 + SCSD DOC LTR; 07/18/2018 TYPE II AND III FACILITIES Board of State and Community Corrections PROCEDURES1 BSCC 5120 5140 5180 FACILITY NAME: Santa Clara County Main Jail (MJ) FACILITY TYPE: II BSCC Code: 5120 DATE: 03/02/2018 PERSON(S) INTERVIEWED: Sergeant Arthur Candelaria, Deputies Allegra Aponte and Brett Bernal FACILITY NAME: Elmwood - Men’s Facility (EMF) FACILITY TYPE: II BSCC Code: 5140 DATE: 03/01/2018 PERSON(S) INTERVIEWED: Sergeant Victoria Solis & Deputy Robert Mickanen FACILITY NAME: Elmwood - Women’s Facility (EWF) FACILITY TYPE: II BSCC Code: 5180 DATE: 03/01/2018 PERSON(S) INTERVIEWED: Sergeant Victoria Solis & Deputy Robert Mickanen FIELD REPRESENTATIVE: Michael J. Bush TITLE 15 SECTION MJ EMF EWF P/P REFERENCE – COMMENTS 1020 CORRECTIONS OFFICER CORE COURSE2 6.03 II. Compliance with training sections 1020, 1023 In addition to provisions of Penal Code Section 831.5, all and 1025 is based upon the most recent annual custodial personnel have successfully completed the Standards Training for Corrections (STC) audit. “Corrections Officer Core Course” as described in Section 179 of Title 15, CCR, within one year of assignment. Yes Yes Yes Custodial personnel may substitute 832.3 PC training and the “Corrections Officer Basic Academy Supplemental Core Course” as described in Section 180, Title 15, CCR as an alternative. 1021 JAIL SUPERVISORY TRAINING 6.03 II, A, 1, b, 1, 2 All supervisory custodial personnel have completed the Yes Yes Yes STC or POST supervisory training within one year of assignment. All supervisory custodial personnel have completed the “Corrections Officer Core Course” identified in Section 1020. (The intent is that core training be completed prior Yes Yes Yes to assuming supervisory responsibilities.) 1 This document is intended for use as a tool during the inspection process; this worksheet may not contain each Title 15 regulation that is required. Additionally, many regulations on this worksheet are SUMMARIES of the regulation; the text on this worksheet may not contain the entire text of the actual regulation. Please refer to the complete California Code of Regulations, Title 15, Minimum Standards for Local Facilities, Division 1, Chapter 1, Subchapter 4 for the complete list and text of regulations. The findings herein, as related to policy, do not constitute an “approval” for content, constitutional, or legal issues. We recommend agencies seek policy review through their legal advisor, risk manager, and other persons deemed appropriate. 2 For STC participating agencies, consistency with training sections 1020, 1023 & 1025 is annually assessed by the STC Division. Unless otherwise indicated, the regulatory intent is for training to occur within one year from the date of assignment. 5120 + Santa Clara SO II PRO.docx;02/29/2018 - 1 - A353 Type 2&3 PRO-05.dot (6/09) TITLE 15 SECTION MJ EMF EWF P/P REFERENCE – COMMENTS 1023 JAIL MANAGEMENT TRAINING 6.03 II, A, 1, C 1, 2 All jail management personnel have completed either the Yes Yes Yes STC or the POST management course specified in Section 182, Title 15, CCR within one year of assignment. 1025 CONTINUING PROFESSIONAL TRAINING 6.03 B, 1 With the exception of any year that a core training module is successfully completed, all facility/system Yes Yes Yes administrators, managers, supervisors and custody personnel have successfully completed the annual required training specified in Section 184, Title 15, CCR. 1027 NUMBER OF PERSONNEL 6.03 B, 1 9.39 I, B There are sufficient personnel on duty at all times Compliance with this section is predicated on the (whenever there is an inmate in custody) to ensure the ability of staff to complete and document at least implementation and operation of all programs and activities hourly inmate safety checks in addition to required by these regulations. ensuring the implementation and operation of all programs and activities required by these regulations. Yes Yes Yes We inspected samples of inmate safety check documentation covering each shift, in each area of the jails. All three facilities continue to improve on their “random” safety checks. We suggest continuous training and reminding staff the importance of random checks. Also, we suggest comparing video tapes against the safety checks logs to litigation purpose. There is a written plan that includes the documentation of 9.37 I. A. 8. “Security/Welfare Checks” are hourly safety checks. recorded in a Post Log Book. Supervisors must sign the log once per shift ensuring accuracy and completeness. 9.39 I. E. Requires observation of inmates “at least once every 60 minutes.” 9.39 I. F. 4. Requires that a Sergeant be notified if the welfare check cannot be completed. 9.39 IV. Rounds are to be made in the minimum- security unit “on an irregular basis every 60 minutes.” Yes Yes Yes EMF: Safety (welfare) check documentation was found compliant. Officers, working in the barracks are still writing down safety check times on a 3 x 5 card and at the end of the shift enter those times in the computer. While not non-compliant, we do not encourage this practice and recommend that a process be developed to immediately record the checks after they are completed. 5120 + Santa Clara SO II PRO.docx;02/29/2018 - 2 - A353 Type 2&3 PRO-05.dot (6/09) TITLE 15 SECTION MJ EMF EWF P/P REFERENCE – COMMENTS There is at least one employee on duty at all times, who 1.25 III. D. 1. shall be immediately available and accessible with the Yes Yes Yes ability to respond to any inmate in the event of an emergency. Whenever one or more female inmates are in custody, there 1.25 III. D. 2. is at least one female employee immediately available and 9.39 II. D. Yes Yes Yes accessible. Note: Reference PC § 4021. A staffing plan is available which indicates personnel Yes Yes Yes assigned and their duties. 1028 1028 FIRE AND LIFE SAFETY STAFF 10.31 Whenever there is an inmate in custody, there is at least Yes Yes Yes one person on duty at all times who meets the BSCC training standards for general fire and life safety. There is at least one person on duty who trained in fire and 1.25 III. D. 3. life safety procedures that relate specifically to the facility. Yes Yes Yes 1029 POLICY AND PROCEDURES MANUAL 3 Unless otherwise indicated, all policy references are cited from the Santa Clara There is a published manual of policies and procedures for County, Department of Correction Office of the the facility that addresses applicable regulations and Sheriff Custody Bureau Policy and Procedure includes: Manual. Yes Yes Yes Each facility has Post Orders. Any new or revised PO is forwarded to the Professional Compliance and Audit Unit (PCAU). Table of organization, including channels of 1.09 Yes Yes Yes communications; Inspections and operations reviews by the facility 1.29 III. Watch Commanders Yes Yes Yes administrator/manager; Use of force; Yes Yes Yes 9.01 Use of restraint equipment, including the restraint of 9.01 Use of Restraints (general) pregnant inmates; 9.01 IV. D. Restraint of pregnant inmates. Note: Reference PC § 6030(f) 9.31 II. Also addresses restraint of pregnant Yes Yes Yes inmates. 9.49 Use of Restraint Chair Screening newly received inmates for release; 11.15 & 11.31 Note: Reference PC § 849(b)(2) and 853.6 PC 849(b)(2) Yes Yes Yes Releases are not allowed. If booked those charged with PC 647(f) are filed upon. Security and control, including: 9.33 Physical counts of inmates; Conducted at the beginning of each shift and at Yes Yes Yes 2300 hours. Post Orders Searches of the facility; Yes Yes Yes 9.03, 9.05 & Post Orders Searches of inmates; Yes Yes Yes 9.05 Contraband control; and, Yes Yes Yes 9.05 & 9.09 Key control. Yes Yes Yes Post Orders 3 Procedures related to security and emergency response may be in a separate manual to ensure confidentiality by limiting general access. 5120 + Santa Clara SO II PRO.docx;02/29/2018 - 3 - A353 Type 2&3 PRO-05.dot (6/09) TITLE 15 SECTION MJ EMF EWF P/P REFERENCE – COMMENTS At least annually, the facility administrator reviews, As a practical matter, this is an ongoing process. evaluates and documents internal and external security Yes Yes Yes measures. Emergency procedures, including: 10.11 Yes Yes Yes Escapes; Disturbances; Yes Yes Yes 10.25 Taking of hostages; Yes Yes Yes 10.17 Civil disturbance; Yes Yes Yes 10.15 Natural disasters; Yes Yes Yes 10.05 Periodic testing of emergency equipment; Yes Yes Yes 10.31 IV. Storage, issue and use of weapons, ammunition, 9.19 Yes Yes Yes chemical agents; and, Storage, issue and use of security devices. Yes Yes Yes 9.19 Suicide prevention; and, Yes Yes Yes 12.05 Segregation of inmates. Yes Yes Yes 13.01, 13.03 The manual is available to all employees. Yes Yes Yes Online-Intranet The manual is comprehensively reviewed and updated at 1.01 IV. Policy requires a more restrictive annual least every two years. review. 1.02 III. The PCAU are to establish a schedule Yes Yes Yes identifying policies to be reviewed during specific months. 1032 FIRE SUPPRESSION PREPLANNING 10.03 There is a fire suppression pre-plan that has been developed Yes Yes Yes in consultation with the responsible fire authority and includes: Note: Reference PC § 6031.1 Monthly fire and life safety inspections by facility staff 10.31 III. Yes Yes Yes with a two-year retention of the inspection record; Fire prevention inspections at least once every two Refer to letter. years; Yes Yes Yes Note: Reference Health and Safety Code Section 13146.1(a) and (b); An evacuation plan; and, Yes Yes Yes 10.09 A plan for the emergency housing of inmates in the 10.33 event of a fire. Yes Yes Yes 1040 POPULATION ACCOUNTING Section 2.4 The facility maintains an inmate demographics accounting Yes Yes Yes system, which reflects the monthly average daily population of sentenced and unsentenced inmates by categories of male, female, and juvenile. The Jail Profile Survey information is provided to the Verified. BSCC. Yes Yes Yes 5120 + Santa Clara SO II PRO.docx;02/29/2018 - 4 - A353 Type 2&3 PRO-05.dot (6/09) TITLE 15 SECTION MJ EMF EWF P/P REFERENCE – COMMENTS 1041 INMATE RECORDS 7.03 There are written policies and procedures for the maintenance of individual inmate records which include intake information, personal property receipts, commitment Yes Yes Yes papers, court orders, reports of disciplinary action taken, medical orders issued by the responsible physician and staff response, and non-medical information regarding disabilities and other limitations. 1044 INCIDENT REPORTS 9.27 There are written policies and procedures for the maintenance of written records of all incidents that result in Yes Yes Yes physical harm, or serious threat of physical harm, to an employee, inmate or other person. Such records include names of persons involved, a description of the incident, actions taken, and date and time of the occurrence. Written record is prepared by appropriate staff and 9.27 I. B. submitted within 24 hours of the incident. Yes Yes Yes 1045 PUBLIC INFORMATION PLAN 1.41 VII. Maintained in the front lobbies. The facility has suitable written policies and procedures for Yes Yes Yes the dissemination of information to the public, government agencies and news media. Title 15, CCR, Minimum Standards for Local Detention Yes Yes Yes Facilities is available for review by the public and inmates. Facility rules and procedures affecting inmates as specified 1.13 III. E. Addresses unrestricted versus in this section are available to the public and inmates. restricted policies and availability to the public Yes Yes Yes at facility lobbies. 1046 DEATH IN CUSTODY 12.09 Yes Yes Yes Written policy and procedures assure that there is a review of each in-custody death. The review team includes the facility administrator and/or 12.09 VII. & VIII. manager; the health administrator; the responsible physician; Yes Yes Yes and other health care and supervision staff who are relevant to the incident. When a minor dies in a facility, the administrator of the 13.13 IV, G, 1 facility provides the Board of State and Community Minors are not held in these facilities. Corrections with a copy of the death in custody report that is submitted to the Attorney General, within 10 days of the NA NA NA death. Note: Reference Government Code § 12525 1050 CLASSIFICATION PLAN 13.01 Yes Yes Yes The facility has a written classification plan designed to properly assign inmates to housing units and activities. Includes receiving screening performed at intake by trained Yes Yes Yes personnel. Includes maintenance of a record of each inmate's classification level, housing restrictions and housing Yes Yes Yes assignments. 5120 + Santa Clara SO II PRO.docx;02/29/2018 - 5 - A353 Type 2&3 PRO-05.dot (6/09) TITLE 15 SECTION MJ EMF EWF P/P REFERENCE – COMMENTS The facility has an actively functioning classification Yes Yes Yes system and/or classification committee as specified. The classification plan includes a channel of appeal by the Yes Yes Yes inmate to the facility manager. Inmates sentenced to more than 60 days may request a review no more than 30 days from the last review. Yes Yes Yes 1051 COMMUNICABLE DISEASES 11.05 I. B. 6. There are written policies and procedures, which require Yes Yes Yes that all inmates with suspected communicable diseases are segregated until a medical evaluation can be completed. In absence of medically trained personnel at the time of 11.01 & 11.03 intake into the facility, an inquiry is made to determine if Medical Staff screen each inmate. the inmate has or has had any communicable diseases, or has observable symptoms of communicable diseases, NA NA NA including but not limited to tuberculosis or other airborne diseases, or other special medical problems identified by the health authority. Inmate's response is noted on booking form and/or 11.03 screening device. Yes Yes Yes 1052 MENTALLY DISORDERED INMATES 13.17 There are written policies and procedures for the Yes Yes Yes identification and evaluation of all mentally disordered inmates. An evaluation by health care staff occurs within 24 hours 12.03 II, A, 1, b 13.03, 13.17, Mental Health of identification or at the next daily sick call, whichever is Manual 4140 earliest. Yes Yes Yes The Main Jail has an Acute Psychiatric Care Unit Segregation may be used if necessary to protect the safety 13.17 III. Use of Seclusion Room (Safety Cell) Yes Yes Yes of the inmate or others. There are provisions for transfer of such inmates to a 13.17 medical facility for diagnosis, treatment, and evaluation of such suspected mental disorder, pursuant to Section 1209, Yes Yes Yes Title 15, CCR. 1053 ADMINISTRATIVE SEGREGATION 13.03 There are written policies and procedures that provide for administrative segregation of inmates who are determined Yes Yes Yes to be prone to: escape; assault staff or other inmates; disrupt operations of the jail; or, are likely to need protection from other inmates. The administrative segregation consists of separate and 13.03 I. D. secure housing with no deprivation of privileges other than those necessary to obtain the objective of protecting Yes Yes Yes inmates and staff. 5120 + Santa Clara SO II PRO.docx;02/29/2018 - 6 - A353 Type 2&3 PRO-05.dot (6/09) TITLE 15 SECTION MJ EMF EWF P/P REFERENCE – COMMENTS 1055 USE OF SAFETY CELL 9.47 I. A The safety cell, specified in Title 24, Part II, Section MJ: Booking area has three safety cells, none of 1231.2.5, is used only to hold inmates who display which are used. The female booking area has a behavior that results in the destruction of property or single safety cell which is rarely used. reveals an intent to cause physical harm to self or others. Yes Yes Yes EMF: Two safety cells are located in the inmate processing area and are never used. EWF: Facility has two safety cells that are rarely used. There are written policies and procedures, written by the 9.47 facility administrator in cooperation with the responsible Yes Yes Yes physician, governing safety cell use. Safety cells are not used for punishment or as a substitute 9.47 Yes Yes Yes for treatment. Placement requires the approval of the facility manager or 9.47 I. B. Yes Yes Yes watch commander, or a designated physician. There are written procedures that assure necessary nutrition 9.47 III. C. Documentation is required on the and fluids are administered. Yes Yes Yes log. Inmates are allowed to retain sufficient clothing, or are 9.47 II. E. provided with a “safety garment” to provide for personal Yes Yes Yes privacy unless risks to the inmate's safety or facility security are documented. Direct visual observation is conducted at least twice every 9.47 III. A. An observation log is posted outside 30 minutes and is documented. the Safety Cell. 9.47 II B. 1. Inmate checks must occur at a Yes Yes Yes minimum of 4 times per hour with such observations at least 10 minutes apart. Continued retention of inmate is reviewed a minimum of 9.47 III B. 2. Supervisory continued retention every eight hours. review is required a minimum of once every hour. Yes Yes Yes 9.47 III C. The watch commander must approve the continued retention every 8 hours thereafter. A medical assessment is secured within 12 hours of 9.47 III. B. Medical staff must assess at placement in this cell or at the next daily sick call, placement and observe an inmate once every whichever is earliest, and medical clearance for continued Yes Yes Yes hour thereafter. Medical clearance for continued retention is secured every 24 hours thereafter. retention is required every 24 hours thereafter. A mental health opinion on placement and retention is 9.47 I. C. secured within 24 hours of placement. Yes Yes Yes 5120 + Santa Clara SO II PRO.docx;02/29/2018 - 7 - A353 Type 2&3 PRO-05.dot (6/09) TITLE 15 SECTION MJ EMF EWF P/P REFERENCE – COMMENTS 1056 USE OF SOBERING CELL 11.05 I. B. 2. The sobering cell, specified in Title 24, Part II, Section MJ: The sobering cell is rarely used for its 1231.2.4, is used for holding inmates who are a threat to intended purpose. Inmates requiring sobering their own safety or the safety of others due to their state of are seated in the common booking area and are Yes NA Yes intoxication and pursuant to written policies and under constant supervision by custody and procedures. medical staff. EWF: No reported use during the cycle. Intermittent direct visual observation of inmates in 9.39 I E. 2. Requires inmate observation sobering cells conducted no less than every half hour. (Welfare Check) “every 30 minutes.” 11.05 II. B. Requires direct visual observation no less than every half hour. Yes NA Yes Documented on a Sobering Cell Observation Log. Policy Amendment dated 11/9/2007 requires “welfare checks…every 15 minutes.” An evaluation by a medical staff person or by custody staff, 11.05 II. A. 2. pursuant to written medical procedures in accordance with Section 1213 of these regulations, occurs whenever any Yes NA Yes inmate is retained in a sobering cell for more than six hours. Such inmates are removed from the sobering cell when 11.05 II. A. 2. they are able to continue with processing. Yes NA Yes 1057 DEVELOPMENTALLY DISABLED 12.01, 12.03 INMATES Medical Protocols Yes Yes Yes There are written procedures for identification and evaluation of all developmentally disabled inmates. A contact to the regional center occurs within 24 hours 18.11 when an inmate is suspected or confirmed to be Yes Yes Yes developmentally disabled. 1058 USE OF RESTRAINT DEVICES 9.49 Use of Restraint Chair There are written polices and procedures for the use of MJ: We suggest custody and health care restraint devices that include: managers continue to jointly review the Yes Yes Yes documentations of restraints placement at regular intervals to ensure that practice and documentations are consistent with regulations standards. acceptable restraint devices; Yes Yes Yes signs or symptoms which should result in immediate Yes Yes Yes medical/mental health referral; availability of CPR equipment; Yes Yes Yes protective housing of restrained persons; Yes Yes Yes provisions for hydration and sanitation needs; and Yes Yes Yes exercising of extremities. Yes Yes Yes Restraints are used only to hold inmates who display 9.49 behavior that results in the destruction of property or Yes Yes Yes reveals an intent to cause physical harm to self or others. 5120 + Santa Clara SO II PRO.docx;02/29/2018 - 8 - A353 Type 2&3 PRO-05.dot (6/09) TITLE 15 SECTION MJ EMF EWF P/P REFERENCE – COMMENTS Restraints are not used as discipline or as a substitute for 9.49 I. D. Yes Yes Yes treatment. Inmates are placed in restraints only with approval of the 9.49 I. F. facility manager, watch commander, or the designated Yes Yes Yes physician. All inmates in restraints are housed alone or in a specified 9.49 I. I. Yes Yes Yes area for restrained inmates. Direct visual observation is conducted and documented at 9.49 II. F. Observation and documentation is least twice every 30 minutes. required 4 times per hour with such observations Yes Yes Yes at least 10 minutes apart. Continued retention in such restraints is reviewed every 9.49 I. D. Policy limits placement to 2 hours. Yes Yes Yes two hours. A medical opinion on placement and retention shall be 9.49 II. D. secured as soon as possible but no later than four hours Yes Yes Yes from the time of placement. Medical review for continued retention in restraint devices 9.49 II. D. Requires medical review every hour. Yes Yes Yes occurs at a minimum of every six hours. A mental health consultation is secured as soon as possible, 9.49 I. C. 2. but no later than eight hours from the time of placement. Yes Yes Yes 1059 USE OF REASONABLE FORCE TO 13.05 IV. COLLECT DNA SPECIMENS, SAMPLES, IMPRESSIONS Note: 13.05 IV. D. 2. The requirement to notify BSCC when force is used is no longer in effect. Policy and procedures describe the use of reasonable force to Yes Yes Yes collect blood specimens, saliva samples, or thumb/palm print impressions from individuals who are required to provide them, but refuse written or oral requests to do so. Policies and procedures address: Note: Reference PC § 296 The use of reasonable force is preceded by 13.05 IV documented efforts to secure voluntary compliance, including advisement of the legal obligation to provide Yes Yes Yes the specimen, sample or impression, and the consequences of failing to do so. Supervisory authorization is obtained prior to use of 13.05 IV Yes Yes Yes reasonable force. If the use of reasonable force includes cell extraction, 9.01, 9.55 the extraction is audio-and video-taped and retained by Yes Yes Yes the department, as required by statute. 1061 INMATE EDUCATION PROGRAM 18.03 Educational 18.04 Vocational Facility administrator has planned and requested an inmate education program from appropriate public officials. When Yes Yes Yes such services are not made available by the appropriate public official, then the facility manager shall develop and implement an educational program with available resources. Voluntary academic and/or vocational education is available to sentenced and pretrial inmates. Yes Yes Yes 5120 + Santa Clara SO II PRO.docx;02/29/2018 - 9 - A353 Type 2&3 PRO-05.dot (6/09) TITLE 15 SECTION MJ EMF EWF P/P REFERENCE – COMMENTS 1062 VISITING 17.01 Yes Yes Yes Facility administrator has developed and implemented written policies and procedures for inmate visiting. (TYPE II ONLY) 17.01 I. A. All inmates in Type II facilities are allowed at least two Yes Yes Yes visits totaling at least one hour per week. (TYPE III ONLY) Inmates in Type III facilities are allowed at least one visit NA NA NA totaling at least one hour per week. Visitation procedures include provisions for visitation by 17.01 II. B. 4. minor children of the inmate. Yes Yes Yes Types and availability of visitation, including: In person only. All visitors must be approved for Note: Reference PC § 6031.1 (June 2017) inmate visiting prior to signing up for visits. Mode of visitation; Visitors to Main Jail North may schedule up to 2 weeks in advance but no less than one hour before a visit. Visitors to Main Jail South may schedule visits up to 3 days in advance but no less than one hour before a visit. Elmwood (Men) Mon-Thurs evenings 7-1030 Fri evenings 8-1030 N/A Sat – Sun morning 8-1030 & afternoon 1-4:30. Elmwood (Female) Sun – Sat Mornings 7-1000 &afternoon 2-900 pm. Visitation hours; Days: Sunday, Monday, Tuesday, Friday, Saturday (closed Wednesdays) Times: 7:00 am – 11:00 am; 1:00 pm – 3:00 pm Time inmates are allowed for visitation; and, Inmates may have two 60-minute visits per week. Any restrictions on inmate visitation. 1063 CORRESPONDENCE 17.13 Postcards The facility administrator has developed written policies Yes Yes Yes and procedures for inmate correspondence. The policy and procedures provide that: There is no limitation placed on the volume of mail an 17.13 I. C. Yes Yes Yes inmate may send or receive. Mail may be read where there is a valid security reason and 17.13 I. G. Yes Yes Yes the facility manager or designee approves. Jail staff does not review inmate correspondence to or from 14.01 I. C. 4.17. state and federal courts, any member of the State Bar or 13 I. F., 17.13 III. C., holder of public office, and the State Corrections Standards 17.13 IV. Yes Yes Yes Authority; however, jail staff may open and inspect such mail only to search for contraband, cash, checks, or money orders in the presence of the inmate. 5120 + Santa Clara SO II PRO.docx;02/29/2018 - 10 - A353 Type 2&3 PRO-05.dot (6/09) TITLE 15 SECTION MJ EMF EWF P/P REFERENCE – COMMENTS Confidential correspondence with the facility administrator 14.01 I. C. 4. Yes Yes Yes and/or manager is permitted. Inmates without funds are permitted at least two postage- 17.13 I. D. Yes Yes Yes paid letters each week to family and friends. Inmates without funds are permitted unlimited postage- 17.13 I. D. paid correspondence with his/her attorney and the courts. Yes Yes Yes 1064 LIBRARY SERVICES 18.05 The facility administrator has developed and implemented Jail Programs (chaplain) operates a library cart. written policies and procedures for inmate library service Private vendor provides legal reference for pro Yes Yes Yes which include access to legal reference materials, current per inmates. No legal reference services for information on community services and resources, represented inmates. religious, educational and recreational reading material. 1065 EXERCISE AND RECREATION 18.07 Yes Yes Yes There are written policies and procedures regarding exercise and recreation. An exercise and recreation program is available to inmates Yes Yes Yes in an area designed for recreation. The program allows a minimum of three hours of exercise 18.07 I. C. distributed over a period of seven days. New computerized system. Assure written documented time matches computerized time. MJ: The Main Jail South facility’s Recreation/Exercise area (Sundeck) was remodeled (modified) by constructing an enclosed recreation yard inside the original Yes Yes Yes recreation yard. These enclosures allow the housing units the flexibility to have more maximum-security inmates participate in recreation. Elmwood (men) Facility exceeds the regulated minimum access to recreation for minimum classifications inmates. 1066 BOOKS, NEWSPAPERS, PERIODICALS, 17.13 VII. AND WRITINGS There are written policies and procedures which permit inmates to purchase, receive and read any book, Yes Yes Yes newspaper, periodical, or writing accepted by the United States Post Office except for specified types of publications as determined by the facility administrator. 1067 ACCESS TO TELEPHONE 17.05 There are written policies and procedures that allow Yes Yes Yes reasonable access to a telephone beyond those telephone calls required by Section 851.5 PC. 5120 + Santa Clara SO II PRO.docx;02/29/2018 - 11 - A353 Type 2&3 PRO-05.dot (6/09) TITLE 15 SECTION MJ EMF EWF P/P REFERENCE – COMMENTS 1068 ACCESS TO COURTS 14.01 There are written policies and procedures to ensure that Yes Yes Yes inmates have access to the courts. Such access shall consist of the following: Unlimited mail as provided in Section 1063(f) of these 14.01, 17.13 Yes Yes Yes regulations. Confidential consultation with attorneys. 14.01 I. B. 4., 17.11 I. G. Yes Yes Yes 1069 INMATE ORIENTATION 1.21 I. C. There are written policies and procedures for the Agency provides an inmate handbook to all implementation of a program reasonably understandable to Yes Yes Yes inmates at housing. inmates designed to orient a newly received inmate at the time of placement in a living area. The program shall be published. Yes Yes Yes The program shall include but not be limited to: Rules regarding correspondence, visiting, and Yes Yes Yes telephone usage; Inmate rules and disciplinary procedures; Yes Yes Yes Grievance procedures; Yes Yes Yes Programs and activities availability and method of Yes Yes Yes application; Medical services; Yes Yes Yes Classification and housing assignments; and, Yes Yes Yes Court appearance where scheduled, if known. Yes Yes Yes 1070 INDIVIDUAL/FAMILY SERVICE 18.11 PROGRAMS There are written policies and procedures to facilitate cooperation with appropriate public or private agencies for Yes Yes Yes individual and/or family social service programs for inmates. Such a program utilizes available community services and resources either by establishing a resource guide or actual service delivery. 1071 VOTING 14.11 & Corresponding Policy Amendment There are written policies and procedures whereby the Inmates are informed in orientation about the Yes Yes Yes county registrar allows qualified voters to vote in local, ability to register. state, and federal elections pursuant to the elections code. 1072 RELIGIOUS OBSERVANCES 18.09 There are written policies and procedures to provide Yes Yes Yes opportunities for inmates to participate in religious services and counseling on a voluntary basis. 1073 INMATE GRIEVANCE PROCEDURE 14.05 Any inmate may appeal and resolve grievances relating to Yes Yes Yes any condition of confinement. There are written policies and procedures that include: 5120 + Santa Clara SO II PRO.docx;02/29/2018 - 12 - A353 Type 2&3 PRO-05.dot (6/09) TITLE 15 SECTION MJ EMF EWF P/P REFERENCE – COMMENTS A grievance form or instructions for registering a 14.05 I. D. grievance. BSCC reviewed a sampling of grievances and Yes Yes Yes did not note any unexpected complaints or issues. Resolution at lowest appropriate staff level. Yes Yes Yes 14.05 I. F. & II. A. Provisions for resolving questions of jurisdiction 14.05 III. A. 2. Yes Yes Yes within the facility. Provisions for appeal to next level of review. Yes Yes Yes 14.05 V. Written reasons for denial at each level of review. Yes Yes Yes 14.05 V. D. Provisions for response in a reasonable time limit. 14.05 IV. A. 3. (30 days) MJ: Much improved in their response. A grievance box along with grievance forms are Yes Yes Yes placed in all units. Supervisors are required to pick up grievances 3 x a day. A normal response has been 5-10 days instead of 35-45 1080 RULES AND DISCIPLINARY PENALTIES 15.01, 13.15, 11.21 There are established rules and disciplinary penalties to Yes Yes Yes guide inmate conduct. Rules are written and posted in housing units and booking 15.01, 13.15, 11.21 area or issued to each inmate. Verbal instructions are provided for inmates with disabilities that limit their ability Rules are listed in the orientation handbook and Yes Yes Yes to read, illiterate inmates and others unable to read English, repeated on the electronic tablets. or material is provided in an understandable form. 1081 PLAN FOR INMATE DISCIPLINE 15.01 The facility administrator has developed and implemented Yes Yes Yes written policies and procedures for inmate discipline, which address the following. A designated subordinate, not involved in the charges, acts 15.01 I. A. 3. Designated Hearing Officer on all formal charges. (DHO) Yes Yes Yes The facility lieutenant is the hearing officer. Minor acts of non-conformance or minor violations are 15.01 I. D. 2. handled informally by staff. We reviewed a sampling of 15 disciplinary cases suitable for major disciplinary outcomes. Yes Yes Yes In all cases, all regulated events were timely and inmates had been served with written notifications in time to prepare their case When there is temporary loss of privileges, there is written 15.01 I. D. 2. b. documentation and a policy of review and appeal to the Yes Yes Yes supervisor. Major violations and repetitive minor violations being 15.01 I. D. 1. handled as major violations are referred to the disciplinary Yes Yes Yes officer in writing by the staff member observing the act(s). 5120 + Santa Clara SO II PRO.docx;02/29/2018 - 13 - A353 Type 2&3 PRO-05.dot (6/09) TITLE 15 SECTION MJ EMF EWF P/P REFERENCE – COMMENTS Inmate is informed of charges in writing. Yes Yes Yes 15.01 II. A. 3. A disciplinary hearing is held no sooner than 24 hours after 15.01 II. C. 1. b. the report has been submitted to the disciplinary officer and Yes Yes Yes the inmate served with a copy of charges. The inmate may waive the 24-hour limitation. Violation(s) acted on no later than 72 hours from the time 15.01 II. C. 1. b. the inmate is informed of the charge(s) in writing unless Yes Yes Yes waived by the inmate or for good cause. The inmate is permitted to appear on his/her behalf at the 15.01 II C. 1. & 15.01 II. E. Yes Yes Yes time of the disciplinary hearing. The facility manager or designee reviews all disciplinary 15.01 Yes Yes Yes actions taken. The inmate is advised in writing of the action taken in the Yes Yes Yes disciplinary proceedings. Pending the disciplinary proceedings, the inmate may be 13.01 B. 3. 15.01 I. A. 5. removed from the general population or program for Yes Yes Yes specified reasons. 1082 FORMS OF DISCIPLINE The degree of punitive actions taken by the disciplinary Yes Yes Yes officer is directly related to the severity of the rule infractions as specified in this section. 1083 LIMITATIONS ON DISCIPLINARY 13.15 I. D. b. ACTIONS 15.01 IV. C. 2. No inmate is continued on disciplinary isolation status We reviewed a sampling of disciplinary Yes Yes Yes beyond 30 consecutive days without review by facility outcomes and noted them to be consistent, manager. Part of this review includes consultation with within the limitations imposed by policy and health care staff. Such reviews continue at least every proportional to the offense. fifteen days thereafter until isolation status has ended. Disciplinary isolation cells have the minimum furnishings 15.01 IV. C. 2. a. and space specified in Title 24, Section 1231.2. Inmates Yes Yes Yes are issued clothing and bedding as specified in Articles 12 and 13 of these regulations. Disciplinary cell occupants who destroy bedding and/or 15.01 IV. C. 2. b. clothing may be deprived of such articles. The decision to Yes Yes Yes deprive inmates of such articles is reviewed by the facility manager or designee every 24 hours. No inmates exercise the right of punishment over other 15.01 IV. C. 3. inmates. Yes Yes Yes Note: Reference PC § 4019.5 A safety cell, as specified in Section 1055 of these 15.01 IV. C. 4. regulations, or any restraint device is not used for Yes Yes Yes disciplinary purposes. No inmate is deprived of implements necessary to maintain 15.01 IV. C. 5. Yes Yes Yes an acceptable level of hygiene as specified in Section 1265. Food is not withheld as a disciplinary measure. Yes Yes Yes 15.01 IV. C. 6. Disciplinary isolation diet described in Section 1247 of 13.15 IV. C. these regulations is only utilized for major violations of Yes Yes Yes institution rules. No disciplinary diets were imposed during our inspections. 5120 + Santa Clara SO II PRO.docx;02/29/2018 - 14 - A353 Type 2&3 PRO-05.dot (6/09) TITLE 15 SECTION MJ EMF EWF P/P REFERENCE – COMMENTS The facility manager approves the initial placement on 13.15 IV. C. 2. the disciplinary isolation diet and ensures that medical Yes Yes Yes staff is notified. In consultation with medical staff, the facility manager 13.15 IV. C. 3. approves any continuation of the diet every 72 hours Yes Yes Yes after the initial placement. Correspondence privileges are not withheld except where 13.15 IV. A. 2., 15.01 IV. C. 8. correspondence regulations have been violated. Decision Yes Yes Yes to withhold correspondence privilege is reviewed every 72 hours. Access to courts and legal counsel is not suspended as a 13.15 IV. A. 2., 3., 15.01 IV. C. 9. disciplinary measure. Yes Yes Yes 1084 DISCIPLINARY RECORDS 15.01 V. A record of all disciplinary infractions and punishment Yes Yes Yes administered is maintained. Note: Reference PC § 4019.5 DETENTION OF MINORS Are minors held in this facility? If yes, the following sections including those summarizing the regulations No No No identified in Title 15, Article 8 apply (Minors in Jails). Note: Reference PC § 207.1(b), 207.6, 707.1 5120 + Santa Clara SO II PRO.docx;02/29/2018 - 15 - A353 Type 2&3 PRO-05.dot (6/09) PHYSICAL PLANT EVALUATION BOARD OF STATE AND COMMUNITY CORRECTIONS - BIENNIAL INSPECTION ADULT TYPE I, II, III AND IV FACILITIES APPLICABLE REGULATIONS: 3/80; 8/86; 5/88; 1/91 Title 24, California Code of Regulations (CCR) BSCC Code: 5120 FACILITY NAME: Santa Clara Main Jail FACILITY TYPE: II APPLICABLE REGULATIONS (Check All That Apply): 3/80: X 8/86: 5/88: X 1/91: OTHER: 1963 & 2005 FIELD REPRESENTATIVE: Michael J. Bush DATE : 03/28/2018 ARTICLE/SECTION YES NO N/A COMMENTS Temporary Holding Cells (2.2) Holding cell T4 is rated for 16 inmates, on the day X of inspection the holding cell contained 26 inmates. Contain 10 square feet of floor per inmate Limited to no more than 16 inmates X No smaller than 40 square feet X Contain sufficient seating to accommodate all inmates X Toilet accessible X Water fountain accessible X Wash basin accessible X Provides clear visual supervision X Telephone accessible X Weapons Locker (3.12) External to the security area and equipped with individual X compartments, locks and keys Temporary Staging Cell or Room (2.3) No cells of this type in the facility. Remainder of checklist deleted from this regulation. 1-91: Added provision for temporary staging cells-rooms X Holds inmates classified and segregated per Title 15 § 1050 and § 1053 Sobering Cells (2.4) See additional comments under sobering cell. X LASE updated to reflect conversion of cells. Contain 20 square feet of floor per inmate Limited to no more than 8 inmates X No smaller than 60 square feet X Contain toilet X Contain washbasin X Contain drinking fountain X Partitions or handrails located next to toilet fixture to X provide support Provide easy, unobstructed visual observation X Padding on the floor X Shower-Delousing Room (3.4) 2 showers located in dress in/out area. X Available in reception/booking Secure Vault or Storage Space (2.1) X Available for inmate valuables 5120 Santa Clara DOC MJ PHY.docx;03/28/2018 - 1 - A381 PHY Type 80 86 88 91.dot (9/98) ARTICLE/SECTION YES NO N/A COMMENTS Telephone (2.1) X Available for inmate use per Penal Code § 851.5 Safety Cells (2.5) X Contain 48 square feet with one floor dimension at least 6 feet and ceiling height of at least 8 feet Limited to no more than one inmate X Contain flush ring toilet with controls located outside the X cell Padded floor, door and walls X Equipped with variable intensity, security light, inaccessible X to occupant Vertical view panel not more than 4 inches wide and at least X 24 inches long, in or adjacent to the door Provide a food pass with lockable shutter no more than 4 inches high and located at least 30 inches above the floor X Single Occupancy Cells (2.6) LASE indicated some of the single cells in the old or south jail were granted a variance to double Maximum capacity of one inmate bunk. It states the variance was granted on 11-09- 76 (unable to locate copy in file). No variance X granted for newer cells. Some Double cells on the 4th and 5th floor was remodel into ADA single cells (2018) Contain a minimum of 60 square feet of floor area in Type I Cells in “south jail” meet the 1963 physical plant X facilities and 70 square feet in Type II and III facilities requirements. Have a minimum ceiling height of 8 feet Remodel cells on 4th and 5th floor ceiling heights X 7’.6”. Contain toilet, washbasin and drinking fountain X Contain a bunk, desk and seat (Desk and seat not required in Some cells with desks do not have seats. This was Type I in later, less restrictive 1986 standards) X for cells in the main (newer portion) jail. Multiple Occupancy Cells (8227) The Multiple Occupancy Cells in “2” and “3” East 8-86: Deleted provision for multiple occupancy cells and cell 207, 2 west contain more inmates than the X standards for square footage allow. Contain 35 square feet per person Limited to no more than 8 inmates X 1963 standards did not set a cap. No smaller than 100 square feet X Minimum ceiling height of 8 feet X Water closet separate from washbasin and drinking fountain There are not sufficient washbasins and toilets to X support the capacity in many of the multiple- occupancy cell, using 1:8 ratio. Sufficient bunks to accommodate each occupant X Provide storage space for each occupant's personal items X Multiple Occupancy Rooms (8229) No cells of this type in the facility. The remainder 8-86: Deleted provision for multiple occupancy rooms of the regulation was deleted from this checklist. X Limited to housing persons in Type III and IV facilities and workers in Type I and II facilities Double Occupancy Cells (2.7) No cells of this type in facility. There were single 5-88: Added provision for double occupancy cells cells in the older portion that were granted X variances to double-bunk. The remainder of the Maximum capacity of two inmates checklist deleted from this regulation. 5120 Santa Clara DOC MJ PHY.docx;03/28/2018 - 2 - A381 PHY Type 80 86 88 91.dot (9/98) ARTICLE/SECTION YES NO N/A COMMENTS Dormitories (2.8) All dorms fall under 1963 standards. Requirement 8-86: Provision for dormitories added was 500 cubic feet per inmates. Dorms are over X their RC. Contain 50 square feet of floor area per inmate and a minimum of 8 feet ceiling height Be designed for no fewer than 8 and no more than 64 1963 called for 4 – 50 inmates. X inmates Facilities having a total rated capacity of 80 inmates or less, X may design dormitories for no fewer than 4 inmates Access to toilets separate from washbasins (ratio 1:8) and Dorms are over their RC. X drinking fountains Provide storage space for each inmates' personal items X Dayrooms (2.9) Requirement deleted 2/99. Some units fall under 1963, whereas other under X 8-86: Added requirement for 3 foot wide corridors in front 1980 standards. of cells-rooms 35 square feet of floor area per inmate X Contain tables and seating to accommodate the maximum X number of inmates served Access to toilets, washbasins and drinking fountains X Available to all inmates in Type II and III facilities (excluding special use cells) and to workers in Type I X facilities Shower (3.4) Several pods and dorms will be out of compliance with showers if they exceed their RC. X Available on a ratio of 1:16 Lighting (3.6) Sufficient to permit easy reading. Night lighting is sufficient to allow good supervision. X 8-86: Specifies at least 20 foot-candles at desk level and in grooming areas, with night lighting not to exceed 5 foot-candles Beds-Bunks (3.5) X 30 inches wide and 76 inches long Comfortable Living Environment [102(c)6] A comfortable living environment is maintained through an X adequate heating and cooling system. Exercise Area -Type II, III and WA IV (2.10) X At least one exercise area must contain a minimum of 900 square feet 8-86: Outdoor exercise area provided X 8-86: Clear height of 15 feet with required surface area meeting a formula of: 80% of maximum rated X inmate population and number of one-hour exercise periods per day = required surface area Program Space - Type II and III (2.11) Sufficient area and furnishings to meet the needs of the X facility programs 5120 Santa Clara DOC MJ PHY.docx;03/28/2018 - 3 - A381 PHY Type 80 86 88 91.dot (9/98) ARTICLE/SECTION YES NO N/A COMMENTS Dining Facilities (2.17) Some inmates eat in their cells. Inmates in the X south jail eat in the chow hall. 15 square feet per inmate being fed Toilets, washbasins and showers are not in the same room or not in view of inmate dining X Visiting (2.18) X Sufficient visiting area Contact visits whenever possible for minimum security inmates X Attorney Interviews (2.26) X Provide for confidential attorney consultation Safety Equipment Storage (2.19) Adequate space is provided for storage of equipment such X as fire extinguishers, SCBA, emergency lights, etc. Janitor Closet (2.20) Each floor and each Mod has closet space. Located in security areas lockable, containing a mop sink X and storage space Storage Rooms (2.21) Sufficient space to accommodate inmate property, bedding X and supplies Audio or Video Monitoring System -NA Type IV (2.22) X Audio monitoring system capable of alerting staff in a central control Video monitoring in corridors, main entries and/or exits and programs or activity areas X Fire Detection and Alarm System [102(c)6] X Automatic fire alarm system capable of alerting staff in a central control point Emergency Power (2.24) Available to provide minimal lighting, maintain X communications, alarm, fire, life and security systems Provide Space for: Barber/beauty shop(2.15) X 8-86: Limit requirement to Type II and III facilities (Deleted 2/99) Canteen (2.16) X 8-86: Added for II, III & IV facilities Confidential Interview Rooms (2.25) 8-86: Added for Type II facilities X 5120 Santa Clara DOC MJ PHY.docx;03/28/2018 - 4 - A381 PHY Type 80 86 88 91.dot (9/98) BOARD OF STATE AND COMMUNITY CORRECTIONS - BIENNIAL INSPECTION ADULT DETENTION FACILITY LIVING AREA SPACE EVALUATION BSCC Code: 5120 FACILITY: Santa Clara County Main Jail TYPE: II RC: 1350 FIELD REPRESENTATIVE: Michael J. Bush DATE: 03/28/2018 ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S Court Movement Area - see notes under individual cells. Changed applicable standards from 1980 to 1988 to reconcile RC with space and/or facility requirements. T1, 2 Holding 1988 2 - (16) (32) 19.0' x 9.5' 1 - 1 1 - Notes: Less 15 sq. ft.; two 14’ benches (c 28 feet of bench) “T” denotes transportation room. Prior LASE listed applicable standards of 1980. Unclear how RC was established, as 1980 standard for toilets is 1:8. However, by applying 1988, later less restrictive standards, it allows for a 1:16 toilet ratio. T3, 4 Holding 1988 2 - (16) (32) 18.5' x 10.0' 1 - 1 1 - Notes: Two 13.8’ benches (c 27.67 feet of bench) – (prior LASE said 30 – re-measured 98-00). Prior LASE listed applicable standards of 1980. Unclear how RC was established, as 1980 standard for toilets is 1:8. However, by applying 1988, later less restrictive standards, it allows for a 1:16 toilet ratio. Changed applicable standards this inspection cycle so consistent with RC. 2016-2018 – 26 inmates were held in T4 T5, 6, 7 Holding 1988 3 - (8) (24) 10.0' x 9.6' 1 - 1 1 - Notes: Each cell has two – 6 foot benches (total 12’ feet of bench per cell) - seating and facilities limit RC. Cells 6 and 7 temporarily used as storage during 2004/06 inspection. T8, 9,10 Holding 1988 3 - (4) (12) 8.5’ x 7.2’ 1 - 1 1 - Notes: Cells 8 – 10 each have one 7.2’ bench (prior LASE listed 8 feet – re-measured 98-00); seating limits RC. T11 Holding 1988 1 - (3) (3) 8.5’ x 7.2’ 1 - 1 1 - Notes: 5 foot bench (prior LASE listed bench space of 8’ > re-measured 98-00). On prior LASE, this cell was grouped with T8-14, each listed as having RC of 4. After re-measuring, RC changed to 3. Seating limits RC. INTAKE A – Male Booking//Receiving Area - see notes under individual cells. Changed applicable standards from 1980 to 1988 to reconcile RC with space and/or facility requirements. No impact on other cells. A-B-C Safety 1988 3 - (1) (3) 5.8' x 8.8' 1 - - - - Notes: Three safety cells. Variable light (switch located in pipe chase adjacent to cell). Grates in A, B &C to be replaced due to grid size. During the 2012-2014 cycle we found that cells A and C were converted to storage and C is not used. I-1 Holding 1988 1 - (8) (8) 15.6’ x 6.9’ 1 - 1 1 - Notes: Dimensions are irregular; 12 foot bench. – cell slightly larger, dimensions reflect depth to partition of alcove containing W/F and T units. Seating limits capacity. Outside security. I-2 Holding 1988 1 - (12) (12) 15.5' x 9.5' 1 - 1 1 - Notes: Irregular room. One 8 foot bench, and one ten foot-eleven inch bench (approx. 19 ft bench) Bench limits capacity (last LASE appears to have used sq. ft to establish RC of 14, changed to 12). Prior LASE listed applicable standards of 1980. Unclear how RC was established, as 1980 standard for toilets/wash basins is 1:8. However, by applying 1988, later less restrictive standards, it allows for a 1:16 toilet ratio. Footage requirements the same. Changed applicable standards this inspection cycle so consistent with RC. I-3 Sobering 1988 1 - (7) (7) 15.4' x 9.6' 1 - 1 1 - Notes: Padded floor; three wall-mounted phones; seating added; they have been using it as a holding cell; depth of 15’4” to back wall, however, it is 11.8’ to the padded partition that separates the room from the alcove with W/F and T facilities in it. *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit; If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 5120 SC DOC MJ LAS:03/28/2018 - 1 - A360 LAS Adult.dot (9/98) ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S I-4 Holding 1988 1 - (14) (14) 15.4' x 9.8' 1 - 1 1 - Notes: Approx. 22’ of bench (two benches, each 10’11”). Padded floor. Seating limits capacity. Prior LASE listed 24’ bench, re- measured 98-00. Prior LASE listed applicable standards of 1980. Unclear how RC was established, as 1980 standard for toilets/wash basins is 1:8. However, by applying 1988, later less restrictive standards, it allows for a 1:16 toilet ratio. Footage requirements the same. Changed applicable standards this inspection cycle so consistent with RC. I-6 Holding 1988 1 - (5) (5) 8.8' x 8.0' 1 - 1 1 - Notes: 8’ bench; less 8 square feet; prior LASE listed 9’ bench, re-measured 98-00. I-7 Holding 1988 1 - (4) (4) 8.6' x 6.5' 1 - 1 1 - Notes: 6.4’ bench, irregular shaped room; prior LASE listed 9 ft bench, re-measured 98-00 I-8 to I-10 Holding 1988 3 - (4) (12) 8.8' x 6.9' 1 - 1 1 - Notes: 6.6’ bench in each cell (prior LASE listed 9’, re-measured 98-00) I-11 Holding 1988 1 - (2) (2) Not measured 1 - 1 1 - Notes: Irregular shape (not measured); 4’ bench Dimensions are irregular. INTAKE B – Female Booking/Receiving Area Note: Restroom available in lobby area for inmate use I-12 Holding 1988 1 - * * 10.3’ x 7.4’ 1 - 1 1 - Notes: Two wall-mounted phones; partition was padded since last inspection; floor padded, grates’ grid space large suggested replacement if use as Sobering (same as with Intake A safety cells); round pillar extends into room about 2.3’ making square footage slightly less than calculated from dimensions. Prior LASE listed RC as (4) – was based on fact there was a 6’ bench in cell. Listed as Holding Cell on last LASE, however does not meet the physical plant standards for one. Does meet those for Sobering Cell > changed this cycle. If department wishes to utilize this as a holding cell, will need to install seating. If used as Sobering, RC would be (4). During the 2012-2014 cycle this cell was closed for restroom use only. I-13 Holding 1988 1 - * * 10.3’ x 7.6’ 1 - 1 1 - Notes: Same as I-12 except no pillar in room. Prior LASE listed RC as (7), as room used to contain a 12’ bench. If used as Sobering, RC would be (4). I-14 Holding 1988 1 - (7) (7) 10.3' X 7.3' 1 - 1 1 - Notes: 12’ bench, partition (not padded), two wall-mounted phones, sq. ft limits capacity D Safety 1988 1 - (1) (1) 8.3' X 6.3' 1 - - - - Notes: Has dimmer switch; less 10 square feet CLASSIFICATION – see notes under individual cells. Changed applicable standards from 1980 to 1988 to reconcile RC with space and/or facility requirements. No impact on other cells. C-A Holding 1988 1 (8) (8) (not measured) 1 - 1 1 - Notes: 8 chairs (not fixed seating); Irregular dimensions; approximately 234 square; 2 phones; RC appears based on the number of seats not footage (2010). Prior LASE listed applicable standards of 1980. 1980 standard for toilets/wash basins are 1:8. By applying 1988, later less restrictive standards, it allows for a 1:16 toilet ratio. Footage requirements the same. Changed applicable standards this inspection cycle so consistent with RC. C-B Holding 1988 1 (7) (7) (not measured) 1 - 1 1 - Notes: 7 chairs (not fixed seating); Irregular dimensions; approximately 131 square feet. RC appears based on Seat not footage (2010). Prior LASE listed applicable standards of 1980. 1980 standard for toilets/wash basins are 1:8. By applying 1988, later less restrictive standards, it allows for a 1:16 toilet ratio. Footage requirements the same. Changed applicable standards this inspection cycle so consistent with RC. C-1 Holding 1988 1 - (3) (3) (not measured) 1 - 1 1 - Notes: 6’ bench; Irregular dimensions; approximately 50 square feet. *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit; If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 5120 SC DOC MJ LAS:03/28/2018 - 2 - A360 LAS Adult.dot (9/98) ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S C-2, 3 Holding 1988 2 - (4) (8) 8.9’ x 6.0’ 1 - 1 1 - Notes: 6’ bench; seating limits capacity H-1 Holding 1988 1 - (4) (4) 8.8' x 7.2' 1 - 1 1 - Notes: 6’ bench; seating limits capacity (prior LASE listed RC of 5) H-2 Holding 1988 1 - (4) (4) (not measured) 1 - 1 1 - Notes: 6’ bench; Irregular dimensions; seating limits capacity (prior LASE listed RC of 5) C-4 Holding 1988 1 - (15) (15) 17.5’ x 10.0 1 - 1 1 - Notes: One 14.1’ bench and one 8.75’ bench = 22.85 feet of bench (prior LASE listed bench as 16’); seating limits capacity. Prior LASE listed applicable standards of 1980. Appears RC was established using bench space; however, 1980 standard for toilets/wash basins are 1:8. By applying 1988, later less restrictive standards, it allows for a 1:16 toilet ratio. Footage requirements the same. Changed applicable standards this inspection cycle so consistent with RC. C5 – 9 Holding 1988 5 - (4) (20) 10.0’ x 7.0’ 1 - 1 1 - Notes: 6’ bench; seating limits capacity. NOTE: Two (2) showers for receiving area are located in dress-out room. There are two more in a second room that was also used for dress-out but was converted to a SRT tactical room, these showers are not accessible to inmates (prior LASE indicated 4 showers, however, now there are only 2). 2nd MEDICAL FLOOR - consists of 3 housing areas 2-C - Infirmary - contains a bathroom area with 1-tub, and 2-showers for all 2D inmates M-1 Multiple 1980 1 4 - Not rated (not measured) 1 - 1 1 - Notes: Primarily used for female inmates. M-2, 3 Single 1980 2 1 - Not rated (not measured) 1 - 1 1 - Notes: Negative pressure rooms M4-7 Single 1980 4 1 - Not rated (not measured) 1 - 1 1 - M8 Single 1980 1 - - - (not measured) - - - - - Notes: Isolation room M9-10 Single 1980 2 1 - Not rated (not measured) 1 - 1 1 - M-11 Multiple 1980 1 10 - Not rated (not measured) 1 - 1 1 - 2 -C – contains a bath area with 1-tub and 2-showers for 2C inmates M – 12 Multiple 1980 1 4 - Not rated (not measured) 1 - 1 1 - M 13 - 19 Single 1980 7 1 - Not rated (not measured) 1 - 1 1 - 2–B Special. Housing - contains a bath area with 1-tub and 2-showers for all 2B inmates; this is special housing for inmates using crutches, wheelchairs, artificial limbs, etc. S – 1 Single 1980 1 1 1 1 12.5' x 10.0' 1 - 1 1 - Notes: Handicap cell, handrails by commode. S 2 – 5 Single 1980 4 1 1 4 12.3' x 6.0' 1 - 1 1 - S – 6 Single 1980 1 1 1 1 12.3' x 10.0' 1 - 1 1 - Notes: Handicap cell; handrails by commode. S 7 – 11 Single 1980 5 1 1 5 12.3' x 6.0' 1 - 1 1 - S 12 Single 1980 1 1 1 1 12.3’ x 10.0' 1 - 1 1 - *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit; If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 5120 SC DOC MJ LAS:03/28/2018 - 3 - A360 LAS Adult.dot (9/98) ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S Notes: Handicap cell; handrails by commode. S 13 - 16 Single 1980 4 1 1 4 12.3' x 6.0' 1 - 1 1 - S 17 Single 1980 1 1 1 1 12.3' x 10.0' 1 - 1 1 - Notes: Handicap cell; handrails by commode. S 18 – 20 Single 1980 3 1 1 3 12.3' x 6.0' 1 - 1 1 - S 21 – 22 Single 1980 2 1 1 2 (not measured) 1 - 1 1 - Notes: Minimum 70 square feet. Handicap cell; handrails by commode. S 23 – 25 Single 1980 3 1 1 3 12.3' x 6.1' 1 - 1 1 - S 26 Single 1980 1 1 1 1 12.3’ x 9.0’ 1 - 1 1 - Notes: Handicap cell; handrails by commode. S 27 – 29 Single 1980 3 1 1 3 12.3’ x 6.1’ 1 - 1 1 - S30 Single 1980 1 1 1 1 (not measured) 1 - 1 1 - Notes: Handicap cell; irregular dimensions; handrails by commode. 4th FLOOR 4A Pod A was divided into three separate pods 2018 (MJB) 4A1 Single 2005 14 1 1 14 12.3’ X 6.0” 1 - 1 1 4 4A2 Single 2005 16 1 1 16 12.3’ X 6.0” 1 - 1 1 4A3 Single 2005 16 1 1 16 12.3’ X 6.0” 4B – housing area consists of three distinct pods 4B1-16 Single 1980 16 1 1 16 12.3’ X 6.0” 1 - 1 1 2* Notes: Two showers in dayroom. 4B 17 – 32 Single 1980 16 1 1 16 12.3’ X 6.0” 1 - 1 1 * Notes: Two showers in dayroom. 4B 33 – 48 Single 1980 16 1 1 16 12.3’ X 6.0” 1 - 1 1 * 4C – housing unit consists of three distinct pods 4C 1 - 16 Single 1980 16 1 1 16 12.3’ X 6.0” 1 - 1 1 2 4C 17 – 32 Single 1980 16 1 1 16 12.3’ X 6.0” 1 - 1 1 4C 33 – 48 Single 1980 16 1 1 16 12.3’ X 6.0” 1 - 1 1 2* 5th FLOOR Pod A was divided into three separate pods 2018 (MJB) 5A1 Single 2005 14 1 1 14 12.3’ X 6.0” 1 - 1 1 4 5A2 Single 2005 16 1 1 16 12.3’ x 6.0’ 1 - 1 1 5A3 Single 2005 16 1 1 16 12.3’ x 6.0’ 1 1 1 5B B Single 1980 32 32 1 32 12.3’ X 6.0” 1 - 1 1 4 Double 1980 16 2 2 32 12.3’ X 6.0” 1 - 1 1 5C C Single 1980 32 32 1 32 12.3’ X 6.0” 1 - 1 1 4 *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit; If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 5120 SC DOC MJ LAS:03/28/2018 - 4 - A360 LAS Adult.dot (9/98) ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S Double 1980 16 2 2 32 12.3’ X 6.0” 1 - 1 1 6th FLOOR –There is a total of 2475 sq. ft. of dayroom space which limits the rated capacity in each pod to 70. (Pod A & B have 95 beds). MJB 10/12 A Single 1980 1 1 1 1 12.3' x 6.0' 1 - 1 1 4 Double 1980 47 2 68 12.3' x 6.0' 1 - 1 1 B Single 1980 32 32 1 32 12.3' x 6.0' 1 - 1 1 4 Double 1980 16 2 2 32 12.3' x 6.0' 1 - 1 1 C Single 1980 1 1 1 1 12.3' x 6.0' 1 - 1 1 4 Double 1980 47 2 68 12.3' x 6.0' 1 - 1 1 7th FLOOR – There is a total of 2475 sq. ft. of dayroom space which limits the rated capacity in each pod to 70. (All Pod have been double bunk). MJB 10/12 7A 1- 48 Double 1980 48 96 2 70 12.3' x 6.0' 1 - 1 1 4 7B 1- 48 Double 1980 48 96 2 70 12.3' x 6.0' 1 - 1 1 4 7C 1- 48 Double 1980 48 96 2 70 12.3' x 6.0' 1 - 1 1 4 8th Floor Acute Psychiatric Unit – has 3 showers inside unit for all inmates housed in 8A 8A 1, 3–44 Special 1980 43 1 1 (43) 12.3’ X 6.0” 1 - 1 1 2 Use Notes: Special use cell type. 8A2 Office Acute Mental Health Unit. Originally 48 beds, it now contains 43 actual beds with 5 cells converted to office space. S1 Safety 1980 1 1 1 (1) 10.5’ x 6.0’ 1 - - - - S2 Seclusio 1980 1 1 1 (1) 10.5’ x 6.0’ 1 - - - - n Room Notes: Safety cell converted to a ‘seclusion room” in acute psychiatric care unit. Restraint Special 1980 1 - - - Not measured - - - - - Rm #1 Use Restraint Special 1980 1 - - - Not measured - - - - - Rm #2 Use 8B 1 – 48 Single 1980 48 1 1 48 12.3' x 6.0' 1 - 1 1 4 Notes: mental health down-class from housing 8A. 8C 1- 48 Single 1980 48 1 1 48 11.5' x 12.2' 1 - 1 1 4 SOUTH JAIL (Old Main Jail) 2nd Floor - East 250 - 1963 1 - - - 10’ x 6.3’ x 9.0’ - - - - - Notes: There is a room in the hall opposite dorm E marked as room 250. It is not used as cell, it has no furnishings or facilities, used as interview room or for storage. E - Dorm > cells 250-255 operated as a dormitory (although none are specifically marked as 250-255). Has 5500 cubic airspace for a total rated capacity of 11 – equipped with 18 beds. Prior LASE lists E-dorm as the former juvenile housing area. Over capacity for space and facilities. 250 - 1963 1 2 - 2* 10’ x 6.3’ x 9.0’ 1 - 1 1 * 251 - 1963 1 2 - 2* 9.9' x 5.9' x 9.0’ 1 - 1 1 * 252 - 1963 1 2 - 2* 10.0' x 6.0’ x 9.0’ 1 - 1 1 * *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit; If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 5120 SC DOC MJ LAS:03/28/2018 - 5 - A360 LAS Adult.dot (9/98) ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S 253 - 1963 1 2 - 2* 10.0' x 6.0’ x 9.0’ 1 - 1 1 * 254 - 1963 1 2 - 2* 9.2' x 6.8’ x 9.0' 1 - 1 1 * 255 - 1963 1 2 - 1* 9.0' x 6.3’ x 9.0' 1 - 1 1 * Notes: E-dorm has two beds per cell + 6 (3 double bunks) in dayroom for total of 18 beds in unit; three tables that seat 4, plus wooden table and 7 plastic chairs; one shower in the unit. Over capacity (space and facilities). RC of 11 based on total unit. Occupancy per room arbitrarily assigned. 2nd West Dorm A Dorm 1963 1 53 32 32 39.0' x 39.0 x 12.0' 3 2 4 1 4 Notes: 3 tables with seating for 26; two sides housing share has adjacent bath and dayroom areas; one side has 27 beds (13 dbl. bunks) and the other has 25 (13 double bunks and 1 single). Over capacity for space and facilities. As facilities limit RC to 32 (wash basins and toilets), it was changed from 36 to 32 98/00 cycle. (Footage allows for 36) 201W – Multiple 1963 3 4 4 12 9.0' x 14.5 x 12.0' 1 - 1 1 * 203W Notes: Three cells; Each cell has T/W/F, 4 bunks, a table w/ 4 seats & phone; Cells 201-216 use the same shower area. 1963 cubic feet requirement yields RC of 3.132. 204W Dorm 1963 1 30 19 16 54.0’ x 16.0’ x 11.0’ 3 - 3 1 2 Notes: Has attached dayroom w/ 2 tables (2 fixed w/ seating for 8), double bunks. Over capacity for space and facilities) 10-12 inspection cycle (MJB) 205W – Multiple 1963 2 8 4 8 10.0' x 17.0 x 11.0' 1 - 1 1 * 206W Notes: Table for 4 in each cell; Cells 201-216 use the same shower area. 1963 cubic feet requirement yields RC of 3.74. Over capacity for space with beds. 207W Multiple 1963 1 8 4 4 9.5' x 17.0’ x 11.0' 1 - 1 1 * Notes: Table for 4; Cells 201-216 use the same shower area. 1963 cubic feet requirement yields RC of 3.553. Over capacity for space with beds. 213-215 Multiple 1963 3 12 7 21 9.0' x 34.0’ x 11.0' 1 - 1 1 * Notes: Each cell w/ 12 beds & 1-table for 4; 3 cells; Cells 201-216 use the same shower area; 1963 cubic feet requirement yields RC of 6.732. Over capacity for space and facilities. 216 Multiple 1963 1 29 14 14 19.0’ x 34.0’ x 11.0’ 2 1 2 2 * Notes: Cells 201-216 use the same shower area. Over capacity for space and facilities. -- Holding 1963 1 - - - 16 x 8.2 1 - 1 1 - Notes: Holding cell adjacent to shower area utilized by 201-216. 6 shower heads. 10/12 inspection cycle MJB. Max Unit - cells in linear design; 1-secure shower in hall for unit 218-221 Single 1963 4 1 1 4 6.0' x 7.8' 1 - 1 1 * 247 Holding 1963 1 - - - Not measured 1 - 1 1 - Notes: Measure bench length next inspection; was not listed on prior LASE Dorm F Dorm 1963 1 4 4 4 16.11' x 14.0' 1 1 1 1 Dorm F was reconverted to a cell in 2013 after being used as a supervisor’s office for many years. It is intended to house civil prisoners. EAST HOUSING – linear design, cells 202-209 in same corridor as 212-219 – 2 showers separates the room sequences 202-209 Single 1963 8 2 1 8 6.0' x 10.8’ x 10.0' 1 - 1 1 * Notes: Prior LASE noted, “16 cells 202-219, 8 are singles. 11-09-76 variance for doubles.” – unable to locate a copy of variance in file. *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit; If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 5120 SC DOC MJ LAS:03/28/2018 - 6 - A360 LAS Adult.dot (9/98) ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S 212-219 Multiple 1963 8 2 1 8 6.0' x 10.8' x 10.0’ 1 - 1 1 * Notes: See notes for 202-209; perhaps listed as multiple due to variance – although unclear why RC remained as 1 per cell; table and 2 chairs per cell. 239 Multiple 1963 1 14 8 8 23.5' x 20.0’ x 10.0’ 1 1 2 1 1 Notes: Dorm w/ a dayroom area part of the cell; 2 tables (ea. w/ 6 seats). Over capacity for space and facilities. The prior LASE listed the RC as 12+, adjusted to 8 during this inspection cycle to meet the facilities’ limitations. Using 1/3 rule for urinals cannot count the existing urinal. If replace urinal with commode, would only be over for space requirements and could readjust RC to 12+. 240 Multiple 1963 1 14 8 8 23.5’ x 20.0’ x 10.0’ 1 1 2 1 1 Notes: 2 tables w/ 8 seats each. Over capacity for space and facilities. The prior LASE listed the RC as 12+, adjusted to 8 during this inspection cycle to meet the facilities’ limitations. Using 1/3 rule for urinals cannot count the existing urinal. If replace urinal with commode, would only be over for space requirements and could readjust RC to 12+. 242 Multiple 1963 1 14 8 8 23.5' x 20.0’ x 10.0' 1 1 2 1 1 Notes: Tables (fixed) and seating for 10. Over capacity for space and facilities. The prior LASE listed the RC as 12+, adjusted to 8 during this inspection cycle to meet the facilities’ limitations. Using 1/3 rule for urinals cannot count the existing urinal. If replace urinal with commode, would only be over for space requirements and could readjust RC to 12+. 243-244 Multiple 1963 1 28 24 24 31.0' x 40.5’ x 10' 2 1 3 1 2 Notes: Rooms marked as 243-244 are joined area; dorm-like with adjacent dayroom; 3 tables and seats for 26. Over capacity for space and facilities. Wash basins/toilets only support RC of 24, unclear how RC was established. As facilities limit RC to 32 (wash basins and toilets), it was changed from 28+ to 24 this cycle. (Footage allows for 25) 245 Multiple 1963 1 24 24 24+ 31.0' x 38.0’ x 10' 2 1 3 1 2 Notes: 3 tables and seating for 26; dorm-like housing with adjacent dayroom. 234 Single 1963 1 1 1 1 6.0' x 9.0’ x 10.0' 1 - 1 1 * Notes: Cell contains desk and chair; uses shower on 2 West. 246 Single 1963 1 1 1 1 6.0' x 9.0’ x 10.0' 1 - 1 1 * Notes: Uses shower on 2 West 3 WEST “LITTLE MAX” – enclosed linear unit on 3rd West w/ 5 cells (324-328); shower in unit for these cells; Prior LASE listed these cells as non-rated capacity of one per cell, stating this area was converted to a staging and recreation area. Prior inspection found 324 a bathroom area only; 3 living cells are being used as such, and 328 has recreation equipment in it. Prior LASE also noted, “11-9-76 variance to double cell” for cells 325-328. Unable to locate copy of variance in file. 324 Single 1963 1 - - - 4.8’ x 9.8’ x 10.0’ 1 - 1 1 - Notes: Used as storage - This is a cell without furnishings, only a combo unit inside. It is marked as 324, which is a duplicate cell number – 324 also listed in north max – on prior LASE was marked as cell 325.4 with (non-rated) capacity of one. 325 Single 1963 1 1 1 1 6.0’ x 8.0’ x 10.0’ 1 - 1 1 - 326 Single 1963 1 1 1 1 6.0’ x 8.0’ x 10.0’ 1 - 1 1 - 327 Single 1963 1 1 1 1 6.0’ x 8.0’ x 10.0’ 1 - 1 1 - 328 Single 1963 1 1 1 1 6.0’ x 8.0’ x 10.0’ 1 1 1 - 329 Single 1963 1 1 1 1 6.0’ x 8.0’ x 10.0’ 1 1 1 Notes: This cell (329) is equipped with exercise equipment, no bunks/beds. SOUTH MAX 301-312 Single 1963 12 1 1 12 6.0' x 8.0’ x 10.0' 1 - 1 1 * *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit; If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 5120 SC DOC MJ LAS:03/28/2018 - 7 - A360 LAS Adult.dot (9/98) ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S Notes: 11-9-76 variance to double cell. Unclear why still marked as RC of 1 per cell. Unable to locate copy of variance in file. Cells are single-bunked. These cells use one shower located in the unit. NORTH MAX 313-324 Single 1963 12 1 1 12 6.0' x 8.0’ x 10.0' 1 - 1 1 * Notes: 11-9-76 variance to double cell. Unclear why still marked as RC of 1 per cell. Unable to locate copy of variance in file. Cells are single-bunked. These cells use one shower located in the unit. B Dorm Dorm 1963 1 44 24 24 30.0' x 48.0’ x 12.0' 2 2 3 1 3 Notes: B &C dorms share a dayroom; both open onto it but have their own separate bath areas. B-dorm contains 23 dbl.-bunks. Over capacity for space and facilities. Wash basins/toilets only support RC of 24. C Dorm Dorm 1963 1 44 22 22` 30.0’ x 44.0’ x 12.0’ 2 2 3 1 3 Notes: See notes above; C-dorm contains 21 dbl -bunks. Notes: Converted to attorney visiting. 331 Multiple 1963 1 6 6 6 13.5' x 20.0’ x 11.0' 1 2 - * Notes: Three showers available for 331-335; verify if fountain accessible and location next cycle. 332-335 Multiple 1963 4 4 4 16 9.5’ x 20.0’ x 11.0’ 1 - 1 2 * Notes: Three showers available for 331-335. 336-338 Multiple 1963 3 16 12 36 19.5’ x 33.0’ x 11.0’ 2 - 2 2 1 Notes: Three cells; each with 8-dbl bunks; seating for 12 in 336 & 337. Over capacity for space. 3 EAST 302-309, Single 1963 16 2 1 16 11.5’ x 6.0' x 10.0’ 1 - 1 1 * 312-319 Notes: 11-9-76 variance to double bunk. Unclear why still marked as RC of 1 per cell. Unable to locate copy of variance in file. 310- 311 are showers. All cells are part of an enclosed linear unit; table w/ 2 seats in each cell; double-bunked. 339 Multiple 1963 1 10 8 8 24.0' x 23.5’ x 10.0' 1 1 2 1 1 Notes: Seating for 10. Over capacity for facilities. Toilets only support RC of 8. Using 1/3 rule for urinals cannot count the existing urinal. As facilities limit RC to 8, it was changed from 12+ to 8 this cycle. If replace urinal with commode, would be in compliance and the RC could be readjust 12+. 340 Multiple 1963 1 12 8 8 24.0' x 20.5’ x 10.0' 1 1 2 - 1 Notes: Over capacity for space and facilities. Toilets only support RC of 8. Using 1/3 rule for urinals cannot count the existing urinal. As facilities limit RC to 8, it was changed from 11+ to 8 this cycle. If replace urinal with commode, would only be over for space requirements and RC could be readjusted to 11. Table and chairs for 10. 10/12 inspection cycle. MJB 341 Multiple 1963 1 14 8 8 24.0' x 20.5’ x 10.0' 1 1 2 1 1 Notes: Seating for 12. Over capacity for space and facilities. Toilets only support RC of 8. Using 1/3 rule for urinals cannot count the existing urinal. As facilities limit RC to 8, it was changed from 11+ to 8 this cycle. If replace urinal with commode, would only be over for space requirements and RC could be readjusted to 11+. 342 Multiple 1963 1 14 8 8 24.0' x 24.0’ x 10.0' 1 1 2 1 1 Notes: Seating for 10. Over capacity for space and facilities. Toilets only support RC of 8. Using 1/3 rule for urinals cannot count the existing urinal. As facilities limit RC to 8, it was changed from 12+ to 8 this cycle. If replace urinal with commode, would only be over for space requirements and RC could be readjusted to 12+. 344 Multiple 1963 1 20 16 16 28.0' x 37.5’ x 10.0' 2 1 2 1 2 *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit; If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 5120 SC DOC MJ LAS:03/28/2018 - 8 - A360 LAS Adult.dot (9/98) ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S Notes: Prior LASE listed 344-355 with combined capacity of 35+ and a notation of 17/18 beds; this cell has 21 beds and seating for 16. Over capacity for space and facilities. Wash basins only support RC of 16, unclear how RC was established. As facilities limit RC to 16, it was changed from 17 to 16 this cycle. Table and Chairs for 16. 10/12 inspection cycle. MJB 345 Multiple 1963 1 20 16 16 28.0' x 37.5’ x 10.0' 2 1 2 1 2 Notes: Prior LASE listed 344-355 with combined capacity of 35+ and a notation of 17/18 beds; this cell has 20 beds and seating for 20. Over capacity for space and facilities. Wash basins only support RC of 16, unclear how RC was established. As facilities limit RC to 16, it was changed from 18 to 16 this cycle. Table and chairs for 20. 10/12 inspection cycle. MJB 346 Multiple 1963 1 10 8 8 28.0’ x 17.0’ x 10.0' 1 1 2 1 1 Notes: 1963 cubic feet requirement yields RC of 9.52. Over capacity for facilities. Toilets only support RC of 8. Using 1/3 rule for urinals cannot count the existing urinal. As facilities limit RC to 8, it was changed from 10 to 8 this cycle. If replace urinal with commode, would be in compliance and the RC could be readjust 10. 347 Multiple 1963 1 14 8 8 No measurements 1 1 2 - 1 Notes: 4559 cubic feet. Over capacity for space and facilities. Toilets only support RC of 8. Using 1/3 rule for urinals cannot count the existing urinal. As facilities limit RC to 8, it was changed from 9 to 8 this cycle. If replace urinal with commode, would only be over for space requirements and RC could be readjusted to 9. 333 Single 1963 1 1 1 1 7.0' x 9.0’ x 10.0' 1 - 1 1 * 334 Single 1963 1 1 1 1 6.0' x 9.0’ x 10.0' 1 - 1 1 * 349 Single 1963 1 1 1 1 5.5' x 9.0’ x 10.0' 1 - 1 1 * 350 Single 1963 1 1 1 1 7.0' x 9.0’ x 10.0' 1 - 1 1 * Notes: Prior LASE noted, “11-9-76 variance to double bunk; now single.” Cells are single-bunked. Cells 333-334 & 349-350 are escorted to Max tier to shower. 351 Single 1963 1 1 1 1 7.0’ x 9.0’ x 10.0’ 1 - 1 1 - Notes: Prior LASE noted, “11-9-76 variance to double bunk; now single.” Cell is single-bunked. Escorted to Max tier to shower. *Total RC was increased by 220 beds 11-3-03 after a review of dayroom space square footage space and fire exits and corridor widths to ensure acceptable egress. *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit; If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 5120 SC DOC MJ LAS:03/28/2018 - 9 - A360 LAS Adult.dot (9/98) PHYSICAL PLANT EVALUATION BOARD OF STATE AND COMMUNITY CORRECTIONS - BIENNIAL INSPECTION ADULT TYPE I, II, III AND IV FACILITIES Applicable Title 24 Regulations: 3/80; 8/86; 5/88; 1/91 BSCC: 5140 FACILITY NAME: Elmwood Complex – Men’s Facility FACILITY TYPE: II APPLICABLE REGULATIONS (Check All That Apply): 3/80: X 8/86: 5/88: 1/91: X OTHER: 1963 FIELD REPRESENTATIVE: Michael J. Bush DATE: 03/01/2018 TITLE 24 SECTION YES NO N/A COMMENTS Temporary Holding Cells (2.2) X Contain 10 square feet of floor per inmate Limited to no more than 16 inmates X No smaller than 40 square feet X Contain sufficient seating to accommodate all inmates X Toilet accessible X Water fountain accessible X Wash basin accessible X Provides clear visual supervision X Telephone accessible X Weapons Locker (3.12) X External to the security area and equipped with individual compartments, locks and keys Temporary Staging Cell or Room (2.3) X 1-91: Added provision for temporary staging cells-rooms Holds inmates classified and segregated per Title 15 § 1050 and § 1053 Limited to holding inmates up to 4 hours X Maximum capacity of no more than 80 inmates X Contains 10 square feet of floor space per inmate and has X a ceiling height of at least 8 feet No smaller than 160 square feet X Contains seating to accommodate all inmates X Contains water closet, wash basin and drinking fountain X Provides unobstructed visual supervision of inmates by X staff Detoxification/Sobering Cells (2.4) X No cells of this type in the facility. 01: Name change to “sobering cell” Contain 20 square feet of floor per inmate Shower-Delousing Room (3.4) X Available in reception/booking 5140 Santa Clara DOC Elmwood (men) PHY.doc; 03/01/2016 - 1 - A381 PHY Type 80 86 88 91.dot (03/01) TITLE 24 SECTION YES NO N/A COMMENTS Secure Vault or Storage Space (2.1) X Available for inmate valuables Telephone (2.1) X Available for inmate use per Penal Code § 851.5 Safety Cells (2.5) X Was previous marked as N/A. There are two safety cells in receiving. However, they are used Contain 48 square feet with one floor dimension at least 6 for storage. feet and ceiling height of at least 8 feet Limited to no more than one inmate X Contain flush ring toilet with controls located outside the X cell Padded floor, door and walls X Equipped with variable intensity, security light, X inaccessible to occupant Vertical view panel not more than 4 inches wide and at X least 24 inches long, in or adjacent to the door Provide a food pass with lockable shutter no more than 4 X inches high and located at least 30 inches above the floor Single Occupancy Cells (2.6) X In previous inspections, some cells in M4 double bunked beyond capacity and would be non- Maximum capacity of one inmate compliant when used. However, during 2016- 2018 cycle, a shower was added to each M4 living unit. Contain a minimum of 60 square feet of floor area in X Type I facilities and 70 square feet in Type II and III facilities Have a minimum ceiling height of 8 feet X Contain toilet, washbasin and drinking fountain X Contain a bunk, desk and seat (Desk and seat not required X in Type I in later, less restrictive 1986 standards) Multiple Occupancy Cells (8227) X No cells of this type. 8-86: Deleted provision for multiple occupancy cells Contain 35 square feet per person Limited to no more than 8 inmates No smaller than 100 square feet Minimum ceiling height of 8 feet Water closet separate from washbasin and drinking fountain Sufficient bunks to accommodate each occupant Provide storage space for each occupant's personal items Multiple Occupancy Rooms (8229) X 8-86: Deleted provision for multiple occupancy rooms Limited to housing persons in Type III and IV facilities and workers in Type I and II facilities Contain 50 square feet of floor area per person and a X During previous inspections cycle marked as minimum of 8 feet ceiling height non-compliance. However, during 2014/2016 cycle they are in compliance. 5140 Santa Clara DOC Elmwood (men) PHY.doc; 03/01/2016 - 2 - A381 PHY Type 80 86 88 91.dot (03/01) TITLE 24 SECTION YES NO N/A COMMENTS Limited to no more than 16 persons X During previous inspections cycle marked as non-compliance. However, during 2014/2016 cycle they are in compliance. Access to toilets separate from washbasins (ratio 1:8) and X During previous inspections cycle marked as drinking fountains non-compliance. However, during 2014/2016 cycle they are in compliance. Provide storage space for each occupant's personal items X Double Occupancy Cells (2.7) X 5-88: Added provision for double occupancy cells Maximum capacity of two inmates Contain a minimum of 60 square feet of floor space in X Type I facilities and 70 square feet in Type II and III facilities Have a minimum ceiling height of 8 feet and one floor X dimension at least 6 feet Contain toilet, washbasin and drinking fountain X Contain 2 bunks, 1 desk and seat (Desk and seat not X required in Type I facilities) Dormitories (2.8) X During previous inspections cycle marked as 8-86: Provision for dormitories added non-compliance. However, during 2014/2016 cycle they are in compliance. Contain 50 square feet of floor area per inmate and a minimum of 8 feet ceiling height Be designed for no fewer than 8 and no more than 64 X inmates Facilities having a total rated capacity of 80 inmates or X less, may design dormitories for no fewer than 4 inmates Access to toilets separate from washbasins (ratio 1:8) and X During previous inspections cycle marked as drinking fountains non-compliance. However, during 2014/2016 01: Ratio changed to 1:10 cycle they are in compliance. Provide storage space for each inmates' personal items X Dayrooms (2.9) X 8-86: Added requirement for 3 foot wide corridors in front of cells-rooms 99: Corridor requirement deleted 35 square feet of floor area per inmate X Contain tables and seating to accommodate the maximum X number of inmates served Access to toilets, washbasins and drinking fountains X Available to all inmates in Type II and III facilities X (excluding special use cells) and to workers in Type I facilities Shower (3.4) X Available on a ratio of 1:16 01: Ratio changed to 1:20 5140 Santa Clara DOC Elmwood (men) PHY.doc; 03/01/2016 - 3 - A381 PHY Type 80 86 88 91.dot (03/01) TITLE 24 SECTION YES NO N/A COMMENTS Lighting (3.6) X Sufficient to permit easy reading. Night lighting is sufficient to allow good supervision. 8-86: Specifies at least 20 foot-candles at desk level and in grooming areas, with night lighting not to exceed 5 foot-candles Beds-Bunks (3.5) X 30 inches wide and 76 inches long Comfortable Living Environment [102(c)6] X A comfortable living environment is maintained through an adequate heating and cooling system. Exercise Area -Type II, III and WA IV (2.10) X At least one exercise area must contain a minimum of 900 square feet 8-86: Outdoor exercise area provided X 8-86: Clear height of 15 feet with required surface area X meeting a formula of: 80% of maximum rated inmate population and number of one-hour exercise periods per day = required surface area Program Space - Type II and III (2.11) X Sufficient area and furnishings to meet the needs of the facility programs Dining Facilities (2.17) X 15 square feet per inmate being fed Toilets, washbasins and showers are not in the same room X or not in view of inmate dining Visiting (2.18) X Sufficient visiting area Contact visits whenever possible for minimum security X inmates Attorney Interviews (2.26) X Provide for confidential attorney consultation Safety Equipment Storage (2.19) X Adequate space is provided for storage of equipment such as fire extinguishers, SCBA, emergency lights, etc. Janitor Closet (2.20) X Located in security areas lockable, containing a mop sink and storage space 5140 Santa Clara DOC Elmwood (men) PHY.doc; 03/01/2016 - 4 - A381 PHY Type 80 86 88 91.dot (03/01) TITLE 24 SECTION YES NO N/A COMMENTS Storage Rooms (2.21) X Sufficient space to accommodate inmate property, bedding and supplies Audio or Video Monitoring System -NA Type IV (2.22) X Audio monitoring system capable of alerting staff in a central control Video monitoring in corridors, main entries and/or exits X and programs or activity areas Fire Detection and Alarm System [102(c)6] X Automatic fire alarm system capable of alerting staff in a central control point Emergency Power (2.24) X Available to provide minimal lighting, maintain communications, alarm, fire, life and security systems Provide Space for: X Barber/beauty shop(2.15) 8-86: Limit requirement to Type II and III facilities 99: Requirement deleted Canteen (2.16) X 8-86: Added for II, III & IV facilities Confidential Interview Rooms (2.25) X 8-86: Added for Type II facilities x 5140 Santa Clara DOC Elmwood (men) PHY.doc; 03/01/2016 - 5 - A381 PHY Type 80 86 88 91.dot (03/01) BOARD OF STATE AND COMMUNITY CORRECTIONS - BIENNIAL INSPECTION ADULT DETENTION FACILITY LIVING AREA SPACE EVALUATION BSCC Code: 5140 FACILITY: Elmwood Complex – Men’s Facility TYPE: II RC: 2399 FIELD REPRESENTATIVE: Michael J. Bush DATE: 03/01/2016 ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S INMATE PROCESSING 206 Holding 1991 1 (4) (4) 55 sq. ft. 1 1 1 207 Holding 1991 1 (4) (4) 55 sq. ft. 1 1 1 Notes: Benches in 206 and 207 measure 78 inches limiting capacity to 4. Room 4 Holding 1991 1 (6) (6) 72 sq. ft. 1 1 1 Notes: Two benches totaling 109 inches limit capacity to 6. 223, 224 Safety 1991 2 (1) (2) 6.0' x 8.11' x 9.1' 1 Notes: Safety Cells are not used. 225 Holding 1991 1 (5) (5) 60 sq. ft. 1 1 1 Notes: Two benches totaling 106 inches limit capacity to 5. Unit Note: Although this inmate processing area was completed in 1991 it was not added to the LASE until the 2012-14 inspection cycle. The area is operated 24/7 exclusively for receiving inmates transferred from the Main Jail. BARRACKS HOUSING Barracks 1 Dorm 1963 1 120 56 56 44.0' x 38.0’ x 11.0' 5 3 8 1 4 Notes: Building with two housing areas (one on each end) and central/common dayroom and bathroom areas. 60 beds each side. Dimensions reflect that of only one of the housing areas. Formerly A & 1A. Dayroom has five tables (4 seats each), extra plastic chairs and a long picnic-style table. It appears the RC was established using the cubic feet requirement. Toilet/urinal fixtures only support a total of 56 for the barracks, as we can only count the urinals as one using the 1/3 formula. Over capacity space and facilities. Barracks 2 Dorm 1963 1 120 56 56 44.0' x 38.0’ x 11.0' 5 3 8 1 5 Notes: Building with two housing areas (one on each end) and central/common dayroom and bathroom areas. 74 beds each side (14 triple-bunks and 16 double-bunks on each side). Dimensions reflect that of only one of the housing areas. Dayroom has five tables (4 seats each) and a long picnic-style table. It appears the RC was established using the cubic feet requirement. Toilets and wash basins only support a total of 48 for the barracks, as we can only count the urinals as one using the 1/3 formula. Over capacity space and facilities. Barracks 3 Dorm 1963 1 50 40 40 29.0' x 65.7' x 12.0’ 4 2 5 1 6 Notes: Prior LASE indicated this housing area was being held in reserve, and only utilized when the facility population increased. It is in use this inspection cycle. Barracks consists of a single housing area. Bathroom urinal is five feet in length (prior LASE listed it as six). Urinal counted as one, as it can only represent 1/3 of the total toilets required. It appears the RC was established using the cubic feet requirement, however, the T/U only support 40. Over capacity (space and facilities). Barracks 4 Dorm 1963 1 60 48 48 27.0' x 90.0’ x 12.0' 5 2 8 1 4 Notes: Dorm housing with 28-double bunks & 4 singles. Dorms 4 & 5 are in a two-story building. Dorm 4 is downstairs with Dorm 5 upstairs. Toilet/urinal fixtures limit the RC to 56. Over capacity (space and facilities). Footage (cubic) supports 58. If requested the RC can be increased from 48 to 56.jm *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit; If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 5140 Santa Clara DOC Elmwood (men) LAS.docx; 03/289/2018 - 1 - A360 LAS Adult.dot (9/98) ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S Barracks 5 Dorm 1963 1 66 48 48 27.0' x 90.0’ x 12.0' 6 2 8 1 4 Notes: Dorm housing with 30-double bunks & 4 singles. Dorms 4 & 5 are in a two-story building. Dorm 4 is downstairs with Dorm 5 upstairs. Prior LASE listed only 5 toilets, this inspection reflects the addition of a 6th toilet. Footage (cubic) supports 58. If requested the RC can be increased from 48 to 58. Over capacity (space and facilities).jm Barracks 6 Dorm 1963 1 62 56 56 120.0' x 27.0’ x 12.0' 6 2 8 1 4 Notes: Dorm housing. Dorms 6 & 7 are in a two-story building. Dorm 6 is downstairs with Dorm 7 upstairs. Toilets/wash basins/showers limit space for 64. Contains 19-double and 12-triple bunks. Prior LASE indicated there were only 4T, 3U and 7W. Increased toilets and additional wash basin can support 64, if agency requested re-evaluation. Over capacity (facilities). Footage would support RC of 77. Over capacity (facilities).jm Barracks 7 Dorm 1963 1 62 56 56 120.0' x 27.0’ x 12.0' 6 2 8 1 4 Notes: Dorm housing. Dorms 6 & 7 are in a two-story building. Dorm 6 is downstairs with Dorm 7 upstairs. Toilets/wash basins/showers limit space for 64. Contains 30-double and 5-single bunks. Prior LASE indicated there were only 4T and 3U. Increased toilets can support 64, if agency requested re-evaluation. Over capacity (facilities). Footage would support RC of 77. Over capacity (facilities).jm Barracks 8 Dorm 1963 1 120 56 56 44.0' x 38.0’ x 11.0' 5 3 8 1 5 Notes: Building with two housing areas (one on each end) and central/common dayroom and bathroom areas. 60 beds each side. Dimensions reflect that of only one of the housing areas. Formerly 8 & 8A. It appears the RC was established using the cubic feet requirement. Toilet/urinal fixtures only support a total of 56 for the barracks, as we can only count the urinals as one using the 1/3 formula. Over capacity space and facilities. RC from 72 to 56 98/00 cycle. If replace one urinal with a toilet, RC could be increased to 64.jm. Dorm closed during the 2014/2016 cycle (MJB). Barracks 9 Dorm 1963 1 120 56 56 44.0' x 38.0’ x 11.0' 5 3 8 1 5 Notes: Building with two housing areas (one on each end) and central/common dayroom and bathroom areas. 60 beds each side. Dimensions reflect that of only one of the housing areas. Formerly 9 & 9A. It appears the RC was established using the cubic feet requirement. Toilet/urinal fixtures only support a total of 56 for the barracks, as we can only count the urinals as one using the 1/3 formula. Over capacity space and facilities. RC from 72 to 56 98/00 cycle. If replace one urinal with a toilet, RC could be increased to 64.jm Barracks 10 Dorm 1963 1 57 32 32 26.0' x 79.0’ x 11.0' 4 2 4 1 6 Notes: Barracks 10 & 11 are in the same building. They share the same central/common bathroom area. Prior LASE indicated these barracks would be replaced with new M-8, however they remain in use. Contains 26-triple and 5 single bunks. Prior LASE listed separate toilet facilities for each Barracks 10 & 11 instead of the combined area. Footage would support RC of 45, limited by facilities. Over capacity (space and facilities). Wash basin/shower fixtures support 64 – split between the two makes for 32 each barrack. Dorm closed during the 2014/2016 cycle (MJB). Barracks 11 Dorm 1963 1 57 32 32 26.0' x 79.0’ x 11.0' 4 2 4 1 6 Notes: Barracks 10 & 11 are in the same building. They share the same central/common bathroom area. Contains 26-triples and 5 singles bunks. Prior LASE listed plumbing fixtures for this unit separate from bldg. 10, however, bathroom is common/shared area. Footage would support RC of 45, limited by facilities. Over capacity (space and facilities). Wash basin/shower fixtures support 64 – split between the two makes for 32 each barrack. Jm Dorm closed during the 2014/2016 cycle (MJB). Barracks 12 Dorm 1963 1 120 56 56 20.0' x 44.0’ x 12.0' 5 3 8 1 5 Notes: Prior LASE listed “12 & 13 were formerly the medium security dorm (north & south) now divided. A & B rooms as dimensioned plus 20’ x 30’ x 12’ in C-room. Remainder (40 x 44) minus (20 x 30) is dayroom.” Building 12 has two housing areas (one on each end) and central/common dayroom and bathroom areas. 60 beds each side. Prior LASE listed RC as 60+, unclear how this was established as *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit; If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 5140 Santa Clara DOC Elmwood (men) LAS.docx; 03/289/2018 - 2 - A360 LAS Adult.dot (9/98) ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S fixtures and footage (based on prior LASE language) support 56. Over capacity (space and facilities). RC changed from 60+ to 56 98/00 cycle. (Unclear what C-room refers to. Jm) Barracks 13 Dorm 1963 1 120 56 56 20.0' x 44.0’ x 12.0' 5 3 8 1 5 Notes: Prior LASE listed “12 & 13 were formerly the medium security dorm (north & south) now divided. A & B rooms as dimensioned plus 20’ x 30’ x 12’ in C-room. Remainder (40 x 44) minus (20 x 30) is dayroom.” Building 13 has two housing areas (one on each end) and central/common dayroom and bathroom areas. 60 beds each side. Prior LASE listed RC as 60+, unclear how this was established as fixtures and footage (based on prior LASE) support 56. RC changed from 60+ to 56 98/00 cycle. (Unclear what C-room refers to. Jm) Barracks 14 Multiple 1980 2 28 8 16 17.3’ x 29.5’ 2 2 2 1 2 – side N Notes: Formerly barracks 18. This is one building with 2 separate and distinct sides. Both sides are self-contained. Each side is made up of two cubicles; dimensions are for one cubicle. This side has 32 beds (6-dbl + 20 single) and facilities of 2/1/2/1/2. On prior LASE, it was listed all under barracks 14 – with 4 cubicles and categorized as a dorm. Dorms were not allowed under 1980 standards, therefore changed to reflect multiple-occupancy room this inspection. Number of beds represents total for this side of the barracks (not per cubicle). Over capacity (space and facilities). RC changed from 10 to 8, per cubicle, 98/00 cycle. Combined total changed from 20 to 16. Fixtures limit capacity. Footage supports 10 per cubicle. jm. Demotion during 2014/2016 cycle (MJB). Barracks 14 Multiple 1980 2 28 10 20 17.3’ x 29.5’ 2 2 2 1 2 – side S Notes: Formerly barracks 18. This is one building with 2 separate and distinct sides. Both sides are self-contained. Each side is made up of two cubicles; dimensions are for one cubicle. This side has 35 beds (11-dbl + 13 single) and facilities of 2/1/3/1/2. On prior LASE, it was listed all under barracks 14 – with 4 cubicles and categorized as a dorm. Dorms were not allowed under 1980 standards, therefore changed to reflect multiple-occupancy room this inspection. Number of beds represents total for this side of the barracks (not per cubicle). Over capacity (space and facilities). jm Demotion during 2014/2016 cycle (MJB). Barracks 15 Multiple 1980 2 23 8 16 17.3’ x 29.5’ 2* 1* 2* 1* 2* – side 1 Notes: Formerly barracks 19. This is one building with 2 separate and distinct sides. Both sides are self-contained. Each side is made up of two cubicles; dimensions are for one cubicle. This side has 29 beds (5-dbl + 19 single) and facilities of 2/1/2/1/2. On prior LASE, it was listed all under barracks 15 – with 4 cubicles and categorized as a dorm. Dorms were not allowed under 1980 standards, therefore changed to reflect multiple-occupancy room this inspection. Number of beds represents total for this side of the barracks (not per cubicle). Over capacity (space and facilities). RC changed from 10 to 8, per cubicle, 98/00 cycle. Combined total changed from 20 to 16. Fixtures limit capacity. Footage supports 10 per cubicle. Demotion during 2014/2016 cycle (MJB). Barracks 15 Multiple 1980 2 23 8 16 17.3’ x 29.5’ 2* 1* 2* 1* 2* – side 2 Notes: Formerly barracks 19. This is one building with 2 separate and distinct sides. Both sides are self-contained. Each side is made up of two cubicles; dimensions are for one cubicle. This side has 30 beds (6-dbl + 18 single) and facilities of 2/1/2/1/2. On prior LASE, it was listed all under barracks 15 – with 4 cubicles and categorized as a dorm. Dorms were not allowed under 1980 standards, therefore changed to reflect multiple-occupancy room this inspection. Number of beds represents total for this side of the barracks (not per cubicle). Over capacity (space and facilities). RC changed from 10 to 8, per cubicle, 98/00 cycle. Combined total changed from 20 to 16. Fixtures limit capacity. Footage supports 10 per cubicle.jm 23 Beds each side during 2012-2014 cycle. T.B. Dorm 1980 (4) - (10) (40) 17.3’ x 29.5’ - - - - - Notes: Transition barracks. Closed by fire department. Not in use this inspection cycle. Due to the fact it is off-line, it is not being included in the RC.jm reaffirmed during 10/12 (MJB) Bldg. 20 Dorm 1980 1 80 36 36 108.0' x 32.7' 10 - 7 - 10 *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit; If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 5140 Santa Clara DOC Elmwood (men) LAS.docx; 03/289/2018 - 3 - A360 LAS Adult.dot (9/98) ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S Notes: Large dorm housing (unclear why listed as multiple); one building with two sides of housing sharing a common/central bathroom; 40-double bunks in Bldg. 20 side. Other side is listed on prior LASE as Bldg. 21 (unclear what the rationale was for listing them separately, as other similar units were not), continued this cycle. No fountain, verify dimensions next cycle. RC appears to have been calculated using combined dayroom and space per inmate requirement of 85 square feet. Over capacity (space and facilities). RC changed from 41 to 36 98/00 cycle. Fixtures limit capacity. Footage supports 41 for Bldg. 20.jm Dorm turned into storage space during the 2014/2016 cycle (MJB). Bldg. 21 Dorm 1980 1 40 36 36 128.5' x 32.7' * * * * * Notes: Converted barn; Large dorm housing (unclear why listed as multiple); one building with two sides of housing sharing a common/central bathroom; 20-double bunks in Bldg. 20 side. Other side is listed on prior LASE as Bldg. 20 (unclear what rationale was for listing separate, as other similar units were not). Four isolation cells (7 x 12.3) that were not rated listed prior LASE, not used – confirm next cycle. No fountain, verify dimensions next cycle. RC appears to have been calculated using combined dayroom and space per inmate requirement of 85 square feet. Over capacity (space and facilities). RC changed from 48 to 36 98/00 cycle. Fixtures limit capacity. Footage supports 48 for Bldg. 20.jm Dorm turned into storage space during the 2014/2016 cycle (MJB). Note: Two dayrooms 476 sq. ft = 952 Total sq ft. RC 27.2 Used for medical inmates due to dayroom space. 529 sq. ft. Will be opened later this year (2018) MJB BUILDING M-1 – Medical and Discipline Housing 313-316 Dorm 1980 4 10 (10 (40) 20.6 x 18.0 x 9 1 1 318-319 S 1980 2 1 (1) (2) 105 sq ft. 1 1 1 321-222 S 1980 2 1 (1) (2) 105 sq ft. 1 1 1 324-325 S 1980 2 1 (1) (2) 105 sq ft. 1 1 1 327-328 S 1980 3 1 (1) (2) 105 sq ft. 1 1 1 330-331- S 1980 2 1 (1) (2) 105 sq ft. 1 1 1 333-336 Dorm 1980 4 10 (10) (40) 20.6 x 18.0 x 9 1 1 338-339 Dorm 1980 2 10 (10) (20) 20.6 x 18.0 x 9 1 1 BUILDING M-2 Consists of four separate housing areas designated as units A, B, C & D.) Prior LASE states, “Variance 9-16-81 for 1/20 shower ratio. Excess housing space allocated to dayrooms.” M-2 is a rectangular-shaped bldg. with two housing areas at each end, for a total of four. (During 10/12 cycle, each housing unit will be counted as one living space, meaning cubicle reference does not apply). For historical reference please refer to previous LASE. Dorms appears to have enough space to house 64 inmates, however, each unit only has 3 showers, which will limit there RC to 60. (MJB) – 5/2012. During the 2016-18 cycle, “A” only had 5 toilets. RC is limited to 50. BCD RC 60. A Multiple 1980 3 68 48 50 5 6 1 3 B Multiple 1980 3 68 48 60 6 6 1 3 C Multiple 1980 3 68 48 60 6 6 1 3 D Multiple 1980 3 70 48 60 6 6 1 3 BUILDING M-3 Consists of four separate housing areas designated as units A, B, C & D.) Prior LASE states, “Variance 9-16-81 for 1/20 shower ratio. Excess housing space allocated to dayrooms.” M-3 is a rectangular-shaped bldg. with two housing areas at each end, for a total of four. (During 10/12 cycle, each housing unit will be counted as one living space, meaning cubicle reference does not apply). By using the current dormitory measurements each dorm has enough space to house 64 inmates; however, each unit only has 3 showers, which will limits there RC to 60. (MJB) – 5/2012. For historical reference please refer to previous LASE. *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit; If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 5140 Santa Clara DOC Elmwood (men) LAS.docx; 03/289/2018 - 4 - A360 LAS Adult.dot (9/98) ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S A Multiple 1980 3 68 60 60 4080 sq. ft 6 6 1 3 B Multiple 1980 3 68 60 60 4080 sq. ft 6 6 1 3 C Multiple 1980 3 68 60 60 4080 sq. ft 6 6 1 3 D Multiple 1980 3 68 60 60 4080 sq. ft. 6 6 1 3 M-4 HOUSING Podular housing design. Bldg. has 4 pods titled A-D. Each pod has two tiers with 24 cells on each tier, for a total of 48 cells per pod. Visiting facilities located inside the bldg. Four holding cells in the bldg. Dayroom space 3,648 for each pod. For historical reference please refer to previous LASE. MJB 10/12 cycle. A Single 1980 7 1 1 7 6.9’ x 11.5’ 1 1 1 5 Double 1980 31 2 2 62 6.9’ x 11.5’ 1 1 1 Notes: Pod A has dbl-bunked the bottom tier and single-bunked top tier, for a total of 64 beds. During 2016-18 inspections 17 single bunks was turned into double bunks + added a shower. (MJB) B Double 1980 24 2 2 48 6.9’ x 11.5’ 1 - 1 1 5 Double 1980 24 2 2 48 6.9’ x 11.5’ 1 1 1 Notes: Pod B is dbl-bunked on both tiers for a total of 96 beds. All sleeping cells double bunk 2016-2018 + added a shower. (MJB) C Double 1980 24 2 1 48 6.9’ x 11.5’ 1 - 1 1 5 Double 1980 24 2 2 48 6.9’ x 11.5’ 1 1 1 Notes: Pod C is dbl-bunked on both tiers for a total of 96 beds. All sleeping cells double bunk 2016-2018 + added a shower. (MJB) D Double 1980 48 2 1 48 6.9’ x 11.5’ 1 - 1 1 5 Double 1980 24 2 2 48 6.9’ x 11.5’ 1 1 1 Notes: Pod D is dbl-bunked on both tiers for a total of 96 beds. All sleeping cells double bunk 2016-2018 + added a shower. (MJB) Holding Holding 1980 4 - (6) (24) 11.0’ x 7.0’ 1 - 1 1 - Notes: two 5.6’ benches in cell for c11’ bench space; footage minus 8.48’. M-5 HOUSING Podular housing design. Bldg. has 4 pods titled A-D. Each pod has two tiers with 24 cells each on tier 48 in pod. Four holding cells in bldg. Dayroom space 3,648 for each pod. For historical reference please refer to previous LASE. MJB 10/12 cycle. A Double 1980 48 2 2 96 6.9’ x 11.5’ 1 - 1 1 5 Notes: Pod A is dbl-bunked on both tiers for a total of 96 beds. B Double 1980 48 2 2 96 6.9’ x 11.5’ 1 - 1 1 5 C Double 1980 48 2 2 96 6.9’ x 11.5’ 1 - 1 1 5 D Double 1980 48 2 2 96 6.9’ x 11.5’ 1 - 1 1 5 Holding Holding 1980 4 - (6) (24) 11.0’ x 7.0’ 1 - 1 1 - Notes: two 5.6’ benches in cell for c11’ bench space; footage minus 8.48’ SPECIAL HOUSING The following housing units are located in the same bldg. and have a common/shared bath area. Prior LASE listed “Four isolation cells 7’ x 12.25’ not counted in capacity.” Not included on facility count sheet during 2012-2014 inspection. Multiple 1980 1 2 8 8 16 17.5’ x 18.5’ 2 2 1 1 *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit; If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 5140 Santa Clara DOC Elmwood (men) LAS.docx; 03/289/2018 - 5 - A360 LAS Adult.dot (9/98) ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S Notes: “Variance granted 5/18/83 to permit 16 capacity.” Housing consists of two cubicles with 8 beds each. M-8 HOUSING Consists of four housing pods; East has Pods A-D; West has Pods E-H POD A: Irregular shaped housing unit with upper and lower tiers; top tier has four cubicles numbered 1-4; 5-8 are downstairs; dimensions are for each cubicle; there is a centralized dayroom in addition to cubicles 7 & 8 being used as dayroom space for a total of 3312.4 sq ft. A Total of 68 beds in this pod but space limits RC to 48. Exercise area attached to pod. For historical reference please refer to previous LASE. (MJB) – 5/2012. Dorm 1991 4 9 8 32 24.5’ x 16.9’ x 9.6’ Dorm 1991 2 16 8 16 24.5’ x 16.9’ x 9.6’ 4 3 6 1 3 POD B: Irregular shaped housing unit with upper and lower tiers; top tier has four cubicles numbered 1-4; 5-8 are downstairs; dimensions are for each cubicle; there is a centralized dayroom in addition to cubicles 7 & 8 being used as dayroom space for a total of 3312.4 sq ft. A Total of 68 beds in this pod but space limits RC to 48. Exercise area attached to pod. For historical reference please refer to previous LASE. (MJB) – 5/2012. Dorm 1991 4 9 8 32 24.5’ x 16.9’ x 9.6’ 4 3 6 1 3 Dorm 1991 2 16 8 16 24.5’ x 16.9’ x 9.6’ POD C: Irregular shaped housing unit with upper and lower tiers; top tier has four cubicles numbered 1-4; 5-8 are downstairs; dimensions are for each cubicle; there is a centralized dayroom in addition to cubicles 7 & 8 being used as dayroom space for a total of 3312.4 sq ft. A Total of 68 beds in this pod but space limits RC to 48. Exercise area attached to pod. For historical reference please refer to previous LASE. (MJB) – 5/2012. Dorm 1991 4 9 8 32 24.5’ x 16.9’ x 9.6’ 4 3 6 1 3 Dorm 1991 2 16 8 16 24.5’ x 16.9’ x 9.6’ POD D: Irregular shaped housing unit with upper and lower tiers; top tier has four cubicles numbered 1-4; 5-8 are downstairs; dimensions are for each cubicle; there is a centralized dayroom in addition to cubicles 7 & 8 being used as dayroom space for a total of 3312.4 sq ft. A Total of 68 beds in this pod but space limits RC to 48. Exercise area attached to pod. For historical reference please refer to previous LASE. (MJB) – 5/2012. Dorm 1991 4 9 8 32 24.5’ x 16.9’ x 9.6’ 4 3 6 1 3 Dorm 1991 2 16 8 16 24.5’ x 16.9’ x 9.6’ A-D 1991 1 7.1 x 8.1 x 9.0 1 1 Note: Otherwise a holding cell this is considered non-rated space as no fountain is installed on the porcelain sink. Bench space of 85 inches would limit capacity to 4 in the event a fountain is added. POD E: Irregular shaped housing unit with upper and lower tiers; top tier has four cubicles numbered 1-4; 5-8 are downstairs; dimensions are for each cubicle; there is a centralized dayroom in addition to cubicles 7 & 8 being used as dayroom space for a total of 3312.4 sq ft. A Total of 68 beds in this pod but space limits RC to 48. Exercise area attached to pod. For historical reference please refer to previous LASE. (MJB) – 5/2012. Dorm 1991 4 9 8 32 24.5’ x 16.9’ x 9.6’ 4 3 6 1 3 Dorm 1991 2 16 8 16 24.5’ x 16.9’ x 9.6’ POD F: Irregular shaped housing unit with upper and lower tiers; top tier has four cubicles numbered 1-4; 5-8 are downstairs; dimensions are for each cubicle; there is a centralized dayroom in addition to cubicles 7 & 8 being used as dayroom space for a total of 3312.4 sq ft. A Total of 68 beds in this pod but space limits RC to 48. Exercise area attached to pod. For historical reference please refer to previous LASE. (MJB) – 5/2012. Dorm 1991 4 9 8 32 24.5’ x 16.9’ x 9.6’ 4 3 6 1 3 Dorm 1991 2 16 8 16 24.5’ x 16.9’ x 9.6’ *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit; If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 5140 Santa Clara DOC Elmwood (men) LAS.docx; 03/289/2018 - 6 - A360 LAS Adult.dot (9/98) ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S POD G: Irregular shaped housing unit with upper and lower tiers; top tier has four cubicles numbered 1-4; 5-8 are downstairs; dimensions are for each cubicle; there is a centralized dayroom in addition to cubicles 7 & 8 being used as dayroom space for a total of 3312.4 sq ft. A Total of 68 beds in this pod but space limits RC to 48. Exercise area attached to pod. For historical reference please refer to previous LASE. (MJB) – 5/2012. Dorm 1991 4 9 8 32 24.5’ x 16.9’ x 9.6’ 4 3 6 1 3 Dorm 1991 2 16 8 16 24.5’ x 16.9’ x 9.6’ POD H: Irregular shaped housing unit with upper and lower tiers; top tier has four cubicles numbered 1-4; 5-8 are downstairs; dimensions are for each cubicle; there is a centralized dayroom in addition to cubicles 7 & 8 being used as dayroom space for a total of 3312.4 sq ft. A Total of 68 beds in this pod but space limits RC to 48. Exercise area attached to pod. For historical reference please refer to previous LASE. (MJB) – 5/2012. Dorm 1991 4 9 8 32 24.5’ x 16.9’ x 9.6’ 4 3 6 1 3 Dorm 1991 2 16 8 16 24.5’ x 16.9’ x 9.6’ E-H 1991 1 7.1 x 8.1 x 9.0 1 1 Notes: Otherwise a holding cell, this is considered non-rated space as no fountain is installed on the porcelain sink. Bench space of 85 inches would limit capacity to 4 in the event a fountain is added. Space added to LASE during 2012-2014 inspection cycle. M-8 COURT STAGING 1 Holding 1991 1 (4) (4) 10.11 x 7.5 x 9.1 1 1 1 Notes: Bench space of 74 inches limits capacity to 4. 2 Holding 1991 1 (4) (4) 10.11 x 8.11 x 9.1 1 1 1 Notes: Bench space of 74 inches limits capacity to 4. 3 Holding 1991 1 (4) (4) 10.11 x 7.4 x 9.1 1 1 1 Notes: Bench space of 74 inches limits capacity to 4. 4 1991 (Not measured) 1 1 1 Notes:: This area was originally intended as a holding cell; however, the area is instead used for storage. 5 1991 Approx. 270 sq. ft. 1 2 1 Notes: Intended as a staging area it is considered non-rated space as no benches are present in this cell. 6-8 1991 1991 3 (4) (12) 10.10 x 7.4 x 9.1 1 1 1 Notes: These cells each contain 74 inches of bench space limiting capacity to 4 each. Area Note: In existence since 1991, the Court Staging area was added to LASE during the 2012-2014 inspection cycle. *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit; If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 5140 Santa Clara DOC Elmwood (men) LAS.docx; 03/289/2018 - 7 - A360 LAS Adult.dot (9/98) BOARD OF STATE AND COMMUNITY CORRECTIONS - BIENNIAL INSPECTION ADULT DETENTION FACILITY LIVING AREA SPACE EVALUATION BSCC Code: 5180 FACILITY: Elmwood Complex – Women’s Facility TYPE: II RC: 634 FIELD REPRESENTATIVE: Michael J. Bush DATE: 03/01/2018 ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S W-3 INTAKE – (not currently utilized) Department ceased processing new bookings at this facility a few years ago. These are handled at the main jail. This facility does process transfers from main jail and commits. Holding areas 6 & 7 are lobby-style seating areas. Prior LASE stated the other holding cells were used for staging. However, in practice they may hold bookings as described above. 1 & 2 Safety 1980 2 - (1) (2) 6.5’ x 8.5’ 1 - - - - 3 Sobering 1980 1 - (4) (4) 10.2’ x 8.9’ 1 - 1 1 - Notes: Prior LASE listed RC as 5, however, footage limits is to (4) – changed 98/00 inspection. 4 Holding 1980 1 - (4) (4) 7.9’ x 9.0’ 1 - 1 1 - Notes: 5 Holding 1980 1 - (4) (4) 7.1’ x 9.0’ 1 - 1 1 - Notes: Prior LASE states 7’ bench limits capacity. 8 Holding 1980 1 - (4) (4) 7.0’ x 11.7’ 1 - 1 1 - Notes: 7-foot bench limits capacity. W-1 – (not currently utilized) used for minimum security housing Safety 1963 1 - 1 (1) 7.0' X 8.0' 1 - - - - Dorm 1 Dorm 1963 1 42 26 26 18.5' X 66.0 X 11.0' 6 - 7 1 4 Notes: Unclear how RC was established, cubic foot requirement limits capacity to 26. Dorm 2 Dorm 1963 1 40 26 26 18.5' X 66.0 X 11.0' 6 - 7 1 4 Notes: Unclear how RC was established, cubic foot requirement limits capacity to 26. jm SPECIAL USE SOUTH –(not currently utilized) enclosed area C 1-6 Single 1963 6 1 1 6 7.5' X 8.5’ X 11.0' 1 - 1 1 * Notes: Single occupancy cells. One shower in unit for these six cells’ use. Prior LASE indicated these cells were double bunked. They were single bunked 98/00 cycle. SPECIAL USE (Felony West) Safety 1963 1 - (1) (1) 7.0' X 8.0' 1 - - - - Notes: Flush ring toilet. C 1-14 Single 1963 14 1 1 14 7.5' X 8.5’ X 11.0' 1 - 1 1 * Notes: Variance for double-occupancy denied 9-13-78. P.C. Housing. Cell #s duplicate the C1-6 above. Two showers available in unit for occupants. Prior LASE listed these cells as being double bunked. They were single bunked 98/00 cycle. *T = Toilets; U = Urinals; W = Wash Basins; F =// Fountains; S = Showers in unit; If "Total RC" appears in brackets ( ), it is not part of //the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 5180 Santa Clara DOC Elmwood (women) LAS .docx ; 03/29/2018 - 1 - A360 LAS Adult.dot (9/98) ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S WDD OBSERVATION (not currently utilized) Obs Single 1963 3 1 (1) (3) 7.4' X 8.5’ X 10.0' 1 - 1 1 - Notes: Prior LASE listed there being 4 single observation cells. There are only 3 in this area. Holding 1963 1 - 5 (5) 7.3' X 7.4’ X 10.0' 1 - 1 1 - Notes: Prior LASE listed 18’`bench – no bench in cell; did contain 6 plastic chairs Holding 1963 1 - 5 (5) 8.2' X 7.6’ X 10.0' 1 - 1 1 - Notes: 20 foot bench; verify seating next cycle – currently used for storage. Holding 1963 1 - 5 (5) 8.2' X 6.4’ X 10.0' 1 - 1 1 - Notes: 20 foot bench; verify seating next cycle – currently used for storage. WOMEN’S MINIMUM MW- Dorm 1986 1 30 11 11 17.3' X 33.0' 6 - 6 1 3 South Notes: Prior LASE indicated it was used as a classroom, but had included it as part of the rated capacity. 98/00 cycle used for housing. Unclear how RC was established. Under either 1980 multiple occupancy room or 1986 dorm-housing standards, required footage per inmate is 50 sq. ft. Based on dimensions above, RC should be 11. The footage does not address dayroom requirements. Additionally, 1980 standards did not provide for dorm housing. As housing footage requirement is the same per inmate under 1980 Multiple and 1986 Dorm, changed listing from 1980 Dorm to 1986 Dorm this cycle. This is based on the maximum capacity for multiple (16) versus dorm (64), and the previously assigned RC. jm MW- Dorm 1986 1 30 11 11 17.3' X 33.0' 6 - 6 1 3 North Notes: Unclear how RC was established. Under either 1980 multiple occupancy room or 1986 dorm-housing standards, required footage per inmate is 50 sq. ft. Based on dimensions above, RC should be 11. The footage does not address dayroom requirements. Additionally, 1980 standards did not provide for dorm housing. As housing footage requirement is the same per inmate under 1980 Multiple and 1986 Dorm, changed listing from 1980 Dorm to 1986 Dorm this cycle. This is based on the maximum capacity for multiple (16) versus dorm (64), and the previously assigned RC. jm W4 – building consists of 3 housing areas; A-C W4 A-Housing – exercise yard adjacent to unit A Single 1980 32 1 1 32 7.0' X 11.0' 1 - 1 1 2 Double 1980 16 2 2 32 7.0' X 11.0' A-Iso Single 1980 2 1 1 2 7.0' X 11.9' 1 - 1 1 2 Notes: Can use showers in general A-Housing area. B Single 1980 48 1 1 32 7.0' X 11.0' 1 - 1 1 4 Double 1980 16 2 2 32 7.0' X 11.0' 1 - 1 1 B-Iso Single 1980 2 1 1 2 7.0' X 11.9' 1 - 1 1 4 Notes: Can use showers in general A-Housing area. W4 C-Housing – contains 3 separate and distinct housing areas (1-3) C1 Single 1980 16 1 1 16 6.9’ X 10.3’ 1 - 1 1 2 Notes: Dayroom has 1 shower upstairs; 1 shower downstairs. *T = Toilets; U = Urinals; W = Wash Basins; F =// Fountains; S = Showers in unit; If "Total RC" appears in brackets ( ), it is not part of //the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 5180 Santa Clara DOC Elmwood (women) LAS .docx ; 03/29/2018 - 2 - A360 LAS Adult.dot (9/98) ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S C2 Single 1980 16 1 1 16 6.9’ X 10.3’ 1 - 1 1 2 C3 Single 1980 16 1 1 16 6.9’ X 10.3’ 1 - 1 1 2 COURT STAGING Staging 1980 1 (16) (16) 410 sq ft 1 1 1 Notes: Add to the LASE during 2012-2014 cycle, this Court staging cell has 2 exits and contains of 6 benches at 108 inches each. The single toilet limits capacity to 16. W-2 HOUSING Notes: Building has 2 sides for housing; each side contains 3 pods each. Side 1 contains pods A-C; Side 2 contains pods D-F. RC raised by adding living area to dayroom space. Each dormitory measure 5,716 sq ft. Although each dormitory can housed up to 64 RC is limited to 60 do to shower ratio. For historical reference please refer to previous LASE. MJB 10/12 cycle. STATION 1 A Dorm 1986 1 72 60 60 5716 sq ft 6 - 7 1 3 B Dorm 1986 1 74 60 60 5716 sq ft 6 - 7 1 3 C Dorm 1986 1 62 60 60 5716 sq ft 6 - 7 1 3 STATION 2 D Dorm 1986 1 84 60 60 5716 sq ft 6 - 7 1 3 E Dorm 1986 1 84 60 60 5716 sq ft 6 - 7 1 3 F Dorm 1986 1 84 60 60 5716 sq ft 6 - 7 1 3 SPECIAL USE – cells located in the W2 building Holding 1980 2 - 3 (6) 8.5' X 5.7' 2 - 2 2 - Notes: One located near each housing workstation. 5.6’ bench. Seating limits capacity. Prior LASE listed RC as (4) per cell, changed to (3) 98/00 cycle. *T = Toilets; U = Urinals; W = Wash Basins; F =// Fountains; S = Showers in unit; If "Total RC" appears in brackets ( ), it is not part of //the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 5180 Santa Clara DOC Elmwood (women) LAS .docx ; 03/29/2018 - 3 - A360 LAS Adult.dot (9/98) PHYSICAL PLANT EVALUATION BOARD OF STATE AND COMMUNITY CORRECTIONS - BIENNIAL INSPECTION ADULT TYPE I, II, III AND IV FACILITIES Applicable Title 24 Regulations: 3/80; 8/86; 5/88; 1/91 BSCC Code: 5180 FACILITY NAME: Elmwood Complex Women’s Facility FACILITY TYPE: II APPLICABLE REGULATIONS (Check All That Apply): 3/80: X 8/86: X 5/88: 1/91: OTHER: 1963 FIELD REPRESENTATIVE: Ron Bertrand DATE: 03/01/2015 TITLE 24 SECTION YES NO N/A COMMENTS Temporary Holding Cells (2.2) X Contain 10 square feet of floor per inmate Limited to no more than 16 inmates X No smaller than 40 square feet X Contain sufficient seating to accommodate all inmates X Toilet accessible X Water fountain accessible X Wash basin accessible X Provides clear visual supervision X Telephone accessible X Weapons Locker (3.12) X External to the security area and equipped with individual compartments, locks and keys Temporary Staging Cell or Room (2.3) X A Court Staging Cell has existed for years; however, it was added to the LASE during 1-91: Added provision for temporary staging cells-rooms 2010-2014 inspection cycle. Holds inmates classified and segregated per Title 15 § 1050 and § 1053 Limited to holding inmates up to 4 hours X Maximum capacity of no more than 80 inmates X Contains 10 square feet of floor space per inmate and has X a ceiling height of at least 8 feet No smaller than 160 square feet X Contains seating to accommodate all inmates X Contains water closet, wash basin and drinking fountain X Provides unobstructed visual supervision of inmates by X staff Sobering Cells (2.4) X 01: Name change to “sobering cell” Contain 20 square feet of floor per inmate Limited to no more than 8 inmates X No smaller than 60 square feet X Contain toilet X Contain washbasin X Contain drinking fountain X Adult Jail..\Cycle\Phy..\5180 Santa Clara DOC Elmwood (womens) PHY.doc; 03/001/2016 - 1 - A381 PHY Type 80 86 88 91.dot (03/01) TITLE 24 SECTION YES NO N/A COMMENTS Partitions or handrails located next to toilet fixture to X provide support Provide easy, unobstructed visual observation X Padding on the floor X Shower-Delousing Room (3.4) X Available in reception/booking Secure Vault or Storage Space (2.1) X Available for inmate valuables Telephone (2.1) X Available for inmate use per Penal Code § 851.5 Safety Cells (2.5) X Two safety cells in W3/ Intake area are under 1980 standards: two safety cells in W-1 are Contain 48 square feet with one floor dimension at least 6 under 1963 Standards. feet and ceiling height of at least 8 feet Limited to no more than one inmate X Contain flush ring toilet with controls located outside the X cell Padded floor, door and walls X Equipped with variable intensity, security light, X Applies to W3 cells only. inaccessible to occupant Vertical view panel not more than 4 inches wide and at X Applies to W3 cells only. least 24 inches long, in or adjacent to the door Provide a food pass with lockable shutter no more than 4 X Applies to W3 cells only. inches high and located at least 30 inches above the floor Single Occupancy Cells (2.6) X Maximum capacity of one inmate Contain a minimum of 60 square feet of floor area in X Type I facilities and 70 square feet in Type II and III facilities Have a minimum ceiling height of 8 feet X Contain toilet, washbasin and drinking fountain X Contain a bunk, desk and seat (Desk and seat not required X This does not apply to the old cells. in Type I in later, less restrictive 1986 standards) Multiple Occupancy Cells (8227) X 8-86: Deleted provision for multiple occupancy cells Contain 35 square feet per person Limited to no more than 8 inmates X No smaller than 100 square feet X Minimum ceiling height of 8 feet X Water closet separate from washbasin and drinking X fountain Sufficient bunks to accommodate each occupant X Provide storage space for each occupant's personal items X Adult Jail..\Cycle\Phy..\5180 Santa Clara DOC Elmwood (womens) PHY.doc; 03/001/2016 - 2 - A381 PHY Type 80 86 88 91.dot (03/01) TITLE 24 SECTION YES NO N/A COMMENTS Multiple Occupancy Rooms (8229) X 8-86: Deleted provision for multiple occupancy rooms Limited to housing persons in Type III and IV facilities and workers in Type I and II facilities Contain 50 square feet of floor area per person and a X minimum of 8 feet ceiling height Limited to no more than 16 persons X Access to toilets separate from washbasins (ratio 1:8) and drinking fountains Provide storage space for each occupant's personal items X Double Occupancy Cells (2.7) X 5-88: Added provision for double occupancy cells Maximum capacity of two inmates Contain a minimum of 60 square feet of floor space in X Type I facilities and 70 square feet in Type II and III facilities Have a minimum ceiling height of 8 feet and one floor X dimension at least 6 feet Contain toilet, washbasin and drinking fountain X Contain 2 bunks, 1 desk and seat (Desk and seat not X required in Type I facilities) Dormitories (2.8) X 8-86: Provision for dormitories added Contain 50 square feet of floor area per inmate and a minimum of 8 feet ceiling height Be designed for no fewer than 8 and no more than 64 X inmates Facilities having a total rated capacity of 80 inmates or X less, may design dormitories for no fewer than 4 inmates Access to toilets separate from washbasins (ratio 1:8) and x . drinking fountains 01: Ratio changed to 1:10 Provide storage space for each inmates' personal items X Dayrooms (2.9) X Requirement deleted in 1999. 8-86: Added requirement for 3 foot wide corridors in front of cells-rooms 99: Corridor requirement deleted 35 square feet of floor area per inmate X Contain tables and seating to accommodate the maximum X number of inmates served Access to toilets, washbasins and drinking fountains X Available to all inmates in Type II and III facilities (excluding special use cells) and to workers in Type I facilities Shower (3.4) X . Available on a ratio of 1:16 01: Ratio changed to 1:20 Adult Jail..\Cycle\Phy..\5180 Santa Clara DOC Elmwood (womens) PHY.doc; 03/001/2016 - 3 - A381 PHY Type 80 86 88 91.dot (03/01) TITLE 24 SECTION YES NO N/A COMMENTS Lighting (3.6) X Sufficient to permit easy reading. Night lighting is sufficient to allow good supervision. 8-86: Specifies at least 20 foot-candles at desk level and in grooming areas, with night lighting not to exceed 5 foot-candles Beds-Bunks (3.5) X 30 inches wide and 76 inches long Comfortable Living Environment [102(c)6] X A comfortable living environment is maintained through an adequate heating and cooling system. Exercise Area -Type II, III and WA IV (2.10) X At least one exercise area must contain a minimum of 900 square feet 8-86: Outdoor exercise area provided X 8-86: Clear height of 15 feet with required surface area X meeting a formula of: 80% of maximum rated inmate population and number of one-hour exercise periods per day = required surface area Program Space - Type II and III (2.11) X Sufficient area and furnishings to meet the needs of the facility programs Dining Facilities (2.17) X Inmates eat in their housing units. 15 square feet per inmate being fed Toilets, washbasins and showers are not in the same room X or not in view of inmate dining Visiting (2.18) X Sufficient visiting area Contact visits whenever possible for minimum security X inmates Attorney Interviews (2.26) X Provide for confidential attorney consultation Safety Equipment Storage (2.19) X Adequate space is provided for storage of equipment such as fire extinguishers, SCBA, emergency lights, etc. Janitor Closet (2.20) X Located in security areas lockable, containing a mop sink and storage space Adult Jail..\Cycle\Phy..\5180 Santa Clara DOC Elmwood (womens) PHY.doc; 03/001/2016 - 4 - A381 PHY Type 80 86 88 91.dot (03/01) TITLE 24 SECTION YES NO N/A COMMENTS Storage Rooms (2.21) X Sufficient space to accommodate inmate property, bedding and supplies Audio or Video Monitoring System -NA Type IV (2.22) X Audio monitoring system capable of alerting staff in a central control Video monitoring in corridors, main entries and/or exits X and programs or activity areas Fire Detection and Alarm System [102(c)6] X Automatic fire alarm system capable of alerting staff in a central control point Emergency Power (2.24) X Available to provide minimal lighting, maintain communications, alarm, fire, life and security systems Provide Space for: X Barber/beauty shop(2.15) 8-86: Limit requirement to Type II and III facilities 99: Requirement deleted Canteen (2.16) X 8-86: Added for II, III & IV facilities Confidential Interview Rooms (2.25) X 8-86: Added for Type II facilities Adult Jail..\Cycle\Phy..\5180 Santa Clara DOC Elmwood (womens) PHY.doc; 03/001/2016 - 5 - A381 PHY Type 80 86 88 91.dot (03/01) COURT HOLDING FACILITIES Board of State and Community Corrections PROCEDURES1 FACILITY NAME: Santa Clara County Family Court (SCF) FACILITY TYPE: CH BSCC CODE: 5200 PERSON(S) INTERVIEWED: Lieutenant James Jenson FACILITY NAME: Santa Clara County Hall of Justice (HOJ) FACILITY TYPE: CHJ BSCC CODE: 5206 PERSON(S) INTERVIEWED: Lieutenant James Jenson FACILITY NAME: Santa Clara County South County Court Holding (SCS) FACILITY TYPE: CHJ BSCC CODE: 5208 PERSON(S) INTERVIEWED: Lieutenant James Jenson FIELD REPRESENTATIVE: Michael J. Bush DATE: 02/26/2018 TITLE 15 SECTION HOJ SCF SCS P/P REFERENCE – COMMENTS 1024 COURT HOLDING AND TEMPORARY C1.10 B. 2. Training includes the use of Court HOLDING FACILITY TRAINING Training Officers (CTO). C6.00 All personnel who are responsible for supervising inmates, and supervisors with custodial responsibilities, complete Jail Operations is a Basic Academy subject and the eight hours of specialized training outlined in this Yes Yes Yes refresher training is conducted within two years regulation within six (6) months of assignment. Successful of graduation from the Basic Academy or within completion of training, pursuant to Section 1020 of these six months upon return to the Court Security regulations, may be substituted for the initial eight hours of Division from other divisions of the department. training. Eight hours of refresher training is completed every two Agency refers to this refresher training as the years. Successful completion of training, pursuant to Title 15 Class. Section 1025 of these regulations, may be substituted for Yes Yes Yes the eight hour refresher. 1027 NUMBER OF PERSONNEL Compliance with this section is predicated on the ability of staff to complete and document hourly There are sufficient personnel on duty at all times safety checks and to ensure the implementation (whenever there is an inmate in custody) to ensure the Yes Yes Yes of operation and all other activities required by implementation and operation of activities required by Title 15. these regulations. 1 This document is intended for use as a tool during the inspection process; this worksheet may not contain each Title 15 regulation that is required. Additionally, many regulations on this worksheet are SUMMARIES of the regulation; the text on this worksheet may not contain the entire text of the actual regulation. Please refer to the complete California Code of Regulations, Title 15, Minimum Standards for Local Facilities, Division 1, Chapter 1, Subchapter 4 for the complete list and text of regulations. 5200 5206 5208 Santa Clara SO CH PRO'.docx; 2/26/2018 - 1 - A350 CH PRO eff. 9/2012.dot TITLE 15 SECTION HOJ SCF SCS P/P REFERENCE – COMMENTS There is a written plan that includes the documentation of C5.13 A. 5. Requires checks every 30 minutes. hourly safety checks. Our discussion with staff resulted in revision of C3.50 B.1. to reflect safety checks be conducted at approximately 30-minute intervals. Our review of safety check documentation Yes Yes Yes revealed that checks are generally conducted hourly. Each facility has done better this inspection cycle by completing random hourly safety checks. There is at least one employee on duty at all times, who C5.10 D. 1. a. shall be immediately available and accessible with the Yes Yes Yes ability to respond to any inmate in the event of an emergency. Whenever one or more female inmates are in custody, there C3.50 A. 2. is at least one female employee immediately available and Yes Yes Yes accessible. Note: Reference PC § 4021. A staffing plan is available which indicates personnel Staffing plans were available for review. assigned and their duties. Yes Yes Yes 1028 1028 FIRE AND LIFE SAFETY STAFF This requirement is met during initial training. Whenever there is an inmate in custody, there is at least one Yes Yes Yes person on duty at all times who meets the BSCC training standards for general fire and life safety. There is at least one person on duty who trained in fire and life safety procedures that relate specifically to the facility. Yes Yes Yes 1029 POLICY AND PROCEDURES MANUAL 2 Unless otherwise indicated, all references noted are contained within the County of Santa Clara - There is a published manual of policies and procedures for Office of the Sheriff - Court Security Division Yes Yes Yes the facility that addresses applicable regulations and Procedures Manual includes: Table of organization, including channels of C2.00 Yes Yes Yes communications; Organizational Chart Page 4 Inspections and operations reviews by the facility C3.15 Yes Yes Yes administrator/manager; Use of force; Yes Yes Yes Department General Order 12.00 Use of restraint equipment, including the restraint of C5.00 pregnant inmates; Yes Yes Yes Policy recently revised to include PC 6030(f) Note: Reference PC § 6030(f) provisions. Security and control, including: C3.50 B. 1. a. Counts are conducted at each Yes Yes Yes Physical counts of inmates; safety check. Searches of the facility; Yes Yes Yes C3.50 C. 3. Searches of inmates; Yes Yes Yes C3.50 C. 6. & C5.10 A. 4. (Remands) Contraband control; and, Yes Yes Yes C3.50 C. 3. Key control. Yes Yes Yes C3.50 C. 2. 2 Procedures related to security and emergency response may be in a separate manual to ensure confidentiality by limiting general access. 5200 5206 5208 Santa Clara SO CH PRO'.docx; 2/26/2018 - 2 - A350 CH PRO eff. 9/2012.dot TITLE 15 SECTION HOJ SCF SCS P/P REFERENCE – COMMENTS At least annually, the facility administrator reviews, evaluates and documents internal and external security Yes Yes Yes measures. Emergency procedures, including: C9.10 Yes Yes Yes Escape; Disturbances; Yes Yes Yes C9.40 Taking of hostages; Yes Yes Yes C9.70 Civil disturbance; Yes Yes Yes C9.40 Natural disasters; Yes Yes Yes C9.12 Periodic testing of emergency equipment; This occurs during the monthly fire/life safety Yes Yes Yes inspections. Storage, issue and use of weapons, ammunition, C3.50 Yes Yes Yes chemical agents; and, Storage, issue and use of security devices. Yes Yes Yes C3.50 Suicide prevention; and, Yes Yes Yes C5.40 Segregation of inmates. Yes Yes Yes C3.50 The manual is available to all employees. Yes Yes Yes Intranet and hard copy in each Sergeant’s office. The manual is comprehensively reviewed and updated at C1.30 B. Requires a more restrictive annual least every two years. Yes Yes Yes update. Last update 12/22/2015. 1032 FIRE SUPPRESSION PREPLANNING C9.60 There is a fire suppression pre-plan that has been developed Yes Yes Yes in consultation with the responsible fire authority and includes: Note: Reference PC § 6031.1 Monthly fire and life safety inspections by facility staff Verified at each facility. Yes Yes Yes with a two-year retention of the inspection record; Fire prevention inspections at least once every two Refer to Attachment A. years; CCA – Overdue No No No Note: Reference Health and Safety Code Section HOJ – Overdue 13146.1(a) and (b);3 SCC – Overdue An evacuation plan; and, Yes Yes Yes C9.10 A plan for the emergency housing of inmates in the County Jail. event of a fire. Yes Yes Yes 1044 INCIDENT REPORTS C6.30 There are written policies and procedures for the maintenance of written records and reporting of all incidents that result in physical harm, or serious threat of Yes Yes Yes physical harm, to an employee, inmate or other person. Such records include names of persons involved, a description of the incident, actions taken, and date and time of the occurrence. Written record is prepared by appropriate staff and C6.35 submitted to the facility manager or his/her designee. Yes Yes Yes 3 Effective 1/1/05, statute was changed to require fire inspections every two years rather than annually. 5200 5206 5208 Santa Clara SO CH PRO'.docx; 2/26/2018 - 3 - A350 CH PRO eff. 9/2012.dot TITLE 15 SECTION HOJ SCF SCS P/P REFERENCE – COMMENTS 1046 DEATH IN CUSTODY C5.40.1 Policy is currently being developed specific to Written policy and procedures assure that there is a review of Yes Yes Yes the court holdings to address this issue. Jail each in-custody death. policy would prevail in the event of an in- custody death. The review team includes the facility administrator and/or manager; the health administrator; the responsible physician; Yes Yes Yes and other health care and supervision staff who are relevant to the incident. When a minor dies in a facility, the administrator of the C5.40.2.C. facility provides the Board of State and Community Corrections with a copy of the death in custody report that is Yes Yes Yes submitted to the Attorney General. Note: Reference Government Code § 12525 1050 CLASSIFICATION PLAN C3.50 C. 5. C5.50 D. If the remanded individual has never been There is a written plan to provide for the safety of staff and booked, he or she will be treated as a “walk- inmates, and segregation, to extent possible, of unusual-risk alone” and kept segregated from all other in- Yes Yes Yes inmates. The plan also includes a method by which such custody defendants/prisoners until the booking information is received and transmitted. paperwork and medical questionnaire has been finished. The remand will be moved to Jail or Juvenile Hall as soon as possible. 1051 COMMUNICABLE DISEASES C5.50 Processing Remands There are written policies and procedures specifying those Yes Yes Yes symptoms that require segregation of an inmate until a medical evaluation can be completed. An inquiry is made to determine if the inmate has or has had any communicable diseases, or has observable symptoms of communicable diseases, including but not Yes Yes Yes limited to tuberculosis or other airborne diseases, or other special medical problems identified by the health authority. Inmate's response is noted on booking form and/or Processing Deputies complete a Pre-booking screening device. Information Sheet Yes Yes Yes #435.19 and Confidential Medical Information form #F435.19A. 1052 MENTALLY DISORDERED INMATES C5.50 There are written policies and procedures for the Yes Yes Yes identification and evaluation of all mentally disordered inmates. An evaluation by health care staff occurs within 24 hours At the County Jail. of identification or at the next daily sick call, whichever is Yes Yes Yes earliest. Segregation may be used if necessary to protect the safety of the inmate or others. Yes Yes Yes 1053 ADMINISTRATIVE SEGREGATION C3.50 C. 5. f. There are written policies and procedures which provide for administrative segregation of inmates who are Yes Yes Yes determined to be prone to: escape; assault staff or other inmates; disrupt operations of the jail; or, are likely to need protection from other inmates. 5200 5206 5208 Santa Clara SO CH PRO'.docx; 2/26/2018 - 4 - A350 CH PRO eff. 9/2012.dot TITLE 15 SECTION HOJ SCF SCS P/P REFERENCE – COMMENTS The administrative segregation consists of separate and secure housing with no deprivation of privileges other than those necessary to obtain the objective of protecting Yes Yes Yes inmates and staff. 1057 DEVELOPMENTALLY DISABLED C3.50 INMATES Yes Yes Yes There are written procedures for identification and evaluation of all developmentally disabled inmates. 1058 USE OF RESTRAINT DEVICES C5.00 (Addresses the use of security restraints, not safety restraints as required by this section.) There are written policies and procedures for the use of restraint devices that include: We were informed that, in practice, any inmate Yes Yes Yes requiring this type of restraint is immediately transported from the court to the jail. Remainder of section deleted. 1068 ACCESS TO COURTS C3.50 There are written policies and procedures that ensure the Yes Yes Yes inmate's right to confidential consultation with attorneys. DETENTION OF MINORS Are minors held in this facility? If yes, the following Most minors will attend court at the Hall of sections, including those summarized in Title 15, Article Justice. However, both Family Court and South Yes Yes Yes 10, apply (Minors in Court Holding Facilities.) Court are able to house minors if they attend court services. 1161 CONDITIONS OF DETENTION C3.50 C. 5. f. C5.15 C. Yes Yes Yes Minors are separated from adults in accordance with Welfare and Institutions Code (WIC) § 208. Minors are segregated in accordance with an established Yes Yes Yes classification plan. There is secure non-public access, movement within and C5.15 egress. If both minors and adults use the same entrance/exit, movements are scheduled in such a manner that there is no Yes Yes Yes opportunity for contact between adult prisoners and minors. 1162 SUPERVISION OF MINORS C3.50 B. 1. a. A sufficient number of personnel are employed in each facility to permit unscheduled supervision of all minors at Yes Yes Yes least twice every 30 minutes and to ensure the implementation and operation of the activities required by these regulations. There is a written plan that includes the documentation of C3.50 B. 1. d. Documentation required on a routine safety checks. Yes Yes Yes “Holding Cell Daily Log.” 5200 5206 5208 Santa Clara SO CH PRO'.docx; 2/26/2018 - 5 - A350 CH PRO eff. 9/2012.dot TITLE 15 SECTION HOJ SCF SCS P/P REFERENCE – COMMENTS 1163 CLASSIFICATION Yes Yes Yes There is a written plan designed to provide for the safety of staff and minors held at the facility. The plan includes receiving and transmitting information C5.13 C. 3. regarding minors who represent a risk or hazard to self or Deputies are responsible for the transportation others while confined at the facility. and supervision of “Direct File” minors. Security information is verbally transmitted to the responsible Deputy from the Juvenile Hall. Yes Yes Yes While the process is compliant, we recommend that this process be documented. The Probation Department is responsible for the transportation and supervision of all other minors. Minors are segregated to the extent possible within the limits Excellent separation exists at SCC. of the court holding facility. HOJ, a facility never built with the intent of holding minors, presents challenges to staff well Yes Yes Yes aware of the separation requirements. Unrated interview rooms are often used in order to accomplish the necessary separation. Minors are separated from adult inmate(s) per WIC § 208. Yes Yes Yes 1047 SERIOUS ILLNESS OR INJURY OF A C5.30 MINOR IN AN ADULT DETENTION FACILITY There are policies and procedures for notifying the court and Yes Yes Yes the parent, guardian or person standing in loco parentis, in the event of a suicide attempt, serious illness, injury or death or a minor in custody. 5200 5206 5208 Santa Clara SO CH PRO'.docx; 2/26/2018 - 6 - A350 CH PRO eff. 9/2012.dot ADULT COURT AND TEMPORARY HOLDING FACILITIES PHYSICAL PLANT EVALUATION BOARD OF STATE AND COMMUNITY CORRECTIONS Applicable Title 24 Regulations: 6/94; 2/99; 2001; 2005; 2008; 2010 BSCC Code: 5200 FACILITY NAME: Santa Clara County Family Justice Center FACILITY TYPE: CHJ APPLICABLE REGULATIONS (Check All That Apply): 6/94: 2/99: 2001: 2005: 2008: 2010: X FIELD REPRESENTATIVE: Michael J. Bush DATE: 03/06/2018 TITLE 24 SECTION YES NO N/A COMMENTS Reception and Booking (2.1) Contains a weapons locker, designed as outlined in these X regulations. Contains a cell or room for confinement pending booking X Contains a detoxification cell (WA in TH; NA in CH) 01: Name changed to “sobering cell.” X 2-99: Two detoxification cells are provided if both male and female inmates are held. Contains safety cell(s) (WA in TH; NA in CH) X Shower room available X 2-99: Access to shower must be within the secure area Provides secure vault or storage for inmate valuables X Telephone(s) available for inmate use (PC § 851.5) X 2-99: Unobstructed access to hot and cold running water X Temporary Holding Cell or Room (2.2) X Contains 10 square feet of floor area per inmate Holds no more than 16 inmates X Is not smaller than 40 square feet and has a clear ceiling X height of 8 feet or more Contains sufficient seating to accommodate all inmates X Contains water closet (toilet), washbasin, and drinking X fountain Provides for clear visual supervision by staff X A bunk is provided if inmates are held 12 hours or more Court Facility. X Temporary Staging Cell or Room (2.3) Holds inmates classified and segregated per Title 15 § 1050 X and 1053 Safety Equipment Storage (2.19) Adequate space is provided to store equipment such as fire X extinguishers, SCBA, emergency lights, etc. Janitors' Closet (2.20) Lockable, containing a mop sink and storage space X 01: Mop sink may be separate from janitors’ closet 5200 SCFJC CH; 06/03/2016 -- A382 PHY CH-TH 94 99 01 05.dot (8/05) TITLE 24 SECTION YES NO N/A COMMENTS Audio or Visual Monitoring (2.22) There is an audio monitoring system capable of alerting staff in a central control. When visual electronic surveillance is use, it is located primarily in corridors, elevators, or at points on the security perimeter such as entrances and exits. X 2-99: Video monitoring option deleted. 10: Deleted language referring to central control point. 10: Terminate at a location where staff can respond immediately. Emergency Power (2.24) There is an emergency power source available and capable of providing minimal lighting in all areas and maintaining X fire and life safety, security, communication and alarm systems. Attorney Interview Space (2.26) Available and provides for confidentiality X Water Closets (Toilets)/Urinals (3.1) Provide for inmate privacy/modesty with staff being able to visual supervise; provided at a ratio of 1:16 in holding and X staging cells. See regulation for calculations of urinal substitutions. Washbasins (3.2) Provide hot and cold or tempered water; provided at a ratio of 1:16 in holding and staging cells. See regulation for X calculations of washbasin trough substitutions. Drinking Fountains (3.3) 2-99: Available in each temporary holding, staging and X sobering cell. Water outlet (bubbler) is mechanically actuated and at an angle that prevents wastewater from flowing over the outlet (bubbler); there is a mouth guard on the water outlet X (bubbler). 2-99: Mouth guard requirement deleted Lighting (3.6) Lighting is sufficient to permit easy reading by a person with normal vision, night lighting is sufficient for purposes of supervision. X Lighting is centrally controlled and/or occupant controlled in housing cells or rooms. Light fixtures are of secure design. Windows (3.7) Windows that are accessible to inmates are no greater than 5 X inches in on dimension. 5200 SCFJC CH; 06/03/2016 -- A382 PHY CH-TH 94 99 01 05.dot (8/05) TITLE 24 SECTION YES NO N/A COMMENTS Seating (3.10) Seating is designed to the level of security. When bench seating is used, eighteen inches of bench are provided per inmate. X 2-99: In holding and staging cells, seating is securely fastened to the wall and/or floor. Weapons Locker (3.12) A secure weapons locker is located outside the security perimeter of the facility and no weapons are brought into X the security area. Lockers have individual compartments, locks and keys. Design Requirements (102(c)6) Design requirements as specified in Title 24, Part 1, 102(c)6 are met. (See regulation for specific requirements. Note X areas of non-compliance that are applicable to the facility type and construction date in the "comments" section.) 5200 SCFJC CH; 06/03/2016 -- A382 PHY CH-TH 94 99 01 05.dot (8/05) ADULT DETENTION FACILITY LIVING AREA SPACE EVALUATION Board of State and Community Corrections BSCC Code: 5200 FACILITY: Santa Clara Family Justice Center TYPE: CHJ RC: (202) FIELD REPRESENTATIVE: Michael Bush DATE 06/03/2016 ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S Basement (Juvenile Area) A1 H 2010 1 (5) 9.5 x7.8 x8.6 1 1 1 Bench Space – 91” A2 H 2010 1 (3) 9.5 x 9.5 x 8.6 1 1 1 Bench Space – 69 “ A3 H 2010 1 (3) 9.5 x 9.2 x 8.6 1 1 1 Bench Space – 70” A4 H 2010 1 (3) 9.5 x 9.5 x 8.6 1 1 1 Bench Space – 62” B1 H 2010 1 (8) 7.9 x 11.3 x 8.6 1 1 1 Bench Space – 93” + 72” =165” B2 H 2010 1 (8) 7.11 x 7.10 x 8.6 1 1 1 Bench Space – 95” + 72 =167” B3 H 2010 1 (8) 7.11 x 7.10 x 8.6 1 1 1 Bench Space – 95” + 72 =167” B4 H 2010 1 (8) 7.11 x 7.10 x 8.6 1 1 1 Bench Space – 95” + 72 =167” B5 H 2010 1 (8) 7.11 x 7.10 x 8.6 1 1 1 Bench Space – 95” + 72 =167” B6 H 2010 1 (2) 9.01 x 7.3 x 8.6 1 1 1 Bench Space –43 “ B7 H 2010 1 (9) 9.1 x 9.9 x 8.6 1 1 1 *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit. If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. Adult Jail…\Cycle\Living…\5200 SCFJC LAS.docx; 06/03/2016 - 1 - A360 LAS Adult-05.dot (8/05) ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S Bench Space – 46” + 117 = 163” B8 H 2010 1 (3) 9.1 x 6.5 x 8.6 1 1 1 Bench Space – 66” B9 H 2010 1 (3) 7.11 x 10.6 x 8.6 1 1 1 Bench Space – 61” C1 H 2010 1 (9) 11.3 x 7.10 x 8.6 1 1 1 Bench Space –94” + 72” =166” C2 H 2010 1 (9) 11.3 x 7.10 x 8.6 1 1 1 Bench Space – 94” + 72” =166” C3 H 2010 1 (4) 11.4 x 9.8 x 8.6 1 1 1 Bench Space – 75” C4 H 2010 1 (9) 10.5 x 8.8 x 8.6 1 1 1 Bench Space – 61 “ + 104” = 165” C5 H 2010 1 (5) 10.5 x 7.7 x 8.6 1 1 1 Bench Space – 91” C6 H 2010 1 (9) 7.7 x 12.1 x 8.6 1 1 1 Bench Space – 70 “ + 91” = 161” C7 H 2010 1 (9) 10.5 x 8.8 x 8.6 1 1 1 Bench Space – 61 “ + 104” = 165” C8 H 2010 1 (5) 10.5 x 7.7 x 8.6 1 1 1 Bench Space – 91” 2nd floor (South) 2A H 2010 1 (11) 12.9 x 9.0 8.6 1 1 1 227Bench Space –31” + 108” + 88” =227” 2B H 2010 1 (9) 12.9 x 7.5 x 8.6 1 1 1 Bench Space – 157 + 118” = 275” *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit. If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. Adult Jail…\Cycle\Living…\5200 SCFJC LAS.docx; 06/03/2016 - 2 - A360 LAS Adult-05.dot (8/05) ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S 3rd floor(South) 3A H 2010 1 (11) 10.8 x 11.10 x 8.6 1 1 1 Bench Space –105” + 98” = 203 3rd Floor (North) 3B H 2010 1 (11) 10.8 x 11.2 x 8.6 1 1 1 Bench Space – 99” + 115” = 214 4th Floor (South) 4A H 2010 1 (6) 9.7 x 10.7 x 8.6 1 1 1 Bench Space –118 4th Floor (North) 4B H 2010 1 (10) 11.10 x 9.1 x 8.6 1 1 1 Bench Space – 133 + 109 + 102 + 64 =408 5th Floor 5A H 2010 1 (10) 10.6 x 10.8 8.61 1 1 1 NOTE: Interview Room on each floor. *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit. If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. Adult Jail…\Cycle\Living…\5200 SCFJC LAS.docx; 06/03/2016 - 3 - A360 LAS Adult-05.dot (8/05) PHYSICAL PLANT EVALUATION BOARD OF STATE AND COMMUNITY CORRECTIONS - BIENNIAL INSPECTION ADULT COURT AND TEMPORARY HOLDING FACILITIES APPLICABLE REGULATIONS: 1/78 Title 24, California Code of Regulations (CCR) BSCC Code: 5206 FACILITY NAME: Santa Clara County Hall of Justice FACILITY TYPE: CHJ APPLICABLE REGULATIONS (Check All That Apply): 1/78: X OTHER: 1988 FIELD REPRESENTATIVE: Michael J. Bush DATE: 03/01/2018 ARTICLE/SECTION YES NO N/A COMMENTS Temporary Holding Cells (2.2) Inmates are moved either in the AM or PM based X on scheduled court time. Contain 10 square feet of floor per inmate Limited to no more than 16 inmates X No smaller than 40 square feet X Contain sufficient seating to accommodate all inmates X Toilet accessible X Wash basin accessible X Drinking fountain accessible X Provide for adequate visual supervision of inmates X Bunk provided to inmates held between hours of 2400 and 0600 (Later, less restrictive 1994 standards only require a X bunk if inmates are held longer than 12 hours) Weapons Locker (3.12) There also are gun lockers located immediately adjacent to each courtroom. External to the security area and equipped with individual X compartments, locks and keys Sobering Cells (WA) (2.4) There are no cells of this type in the court holding X facilities. Text of this regulation is deleted from this checklist. Safety Cells (WA) (2.5) There are no cells of this type in the court holding facilities. Text of this regulation is deleted from X Contain 48 square feet with one floor dimension at least 6 this checklist. feet Shower-Delousing Room (3.4) X Available Secure Vault or Storage Space (2.1) Individuals remanded to jail are searched and property removed, inventoried and placed in a X Available for inmate valuables locked container for transport to the Jail with the inmate. Telephone (2.1) Inmates will use phone when they return back to jail. X Available for inmate use per Penal Code § 851.5 Audio Monitoring (2.22) Cameras are in the hallways and monitors are located in the workstations. There are call buttons For facilities planned or constructed after 8-86 X located in the attorney rooms. Each bailiff has a video-monitor that looks into the hallway of his or her holding area. Janitor Closet (2.20) X 5206 SCSO Hall of Justice PHY.docx; 03/01/2018 - 1 - A370 PHY CH-TH 1-78.dot (9/98) ARTICLE/SECTION YES NO N/A COMMENTS Available Storage Rooms (WA) (2.21) X Available Emergency Power (2.24) Available to maintain fire and life safety, security, X communications and alarm systems Attorney Interview Space (2.26) X Available 5206 SCSO Hall of Justice PHY.docx; 03/01/2018 - 2 - A370 PHY CH-TH 1-78.dot (9/98) BOARD OF STATE AND COMMUNITY CORRECTIONS - BIENNIAL INSPECTION ADULT DETENTION FACILITY LIVING AREA SPACE EVALUATION BSCC Code: 5206 FACILITY: Santa Clara County Hall of Justice TYPE: CHJ RC: 0 FIELD REPRESENTATIVE: Michael J. Bush DATE: 2/04/2016 ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S WORK STATION #1 Basement (Work Station 1) – no cell labeled I; no 2nd floor – the first accessible floor from the basement elevator is the 3rd floor A Holding 1980 1 - 12 (12) 8.8’ x 13.9’ 1 - 1 1 - Notes: 18’ bench B Holding 1980 1 - 1 (1) 6.0’ x 6.8’ 1 - 1 1 - Notes: 2.5’ bench C Holding 1980 1 - 1 (1) 5.9’ x 6.8’ 1 - 1 1 - Notes: 2.5’ bench D Holding 1980 1 - 1 (1) 5.8’ x 6.8’ 1 - 1 1 - Notes: 2.5’ bench E Holding 1980 1 - 1 (1) 5.8’ x 6.8’ 1 - 1 1 - Notes: 2.5’ bench F Holding 1980 1 - 1 (1) 6.1’ x 6.8’ 1 - 1 1 - Notes: 2.5’ bench G Holding 1980 1 - 0 (0) 7.8’ x 19.1’ 1 - 1 1 - Notes: 20.2’ bench. During the 2006-2008 cycle the LASE was adjusted to reflect that cell G is now used for storage. Originally rated for 13 H Holding 1980 1 - 22 (22) 15.7’ x 15.8’ 2 - 1 1 - Notes: 6.4’ x 5.1’ cutout; 34.3’ bench J Holding 1980 1 - 22 (22) 15.4 X 15.6 2 - 1 1 - Notes: used for females; 33’ bench K Holding 1980 1 - 22 (22) 15.6’ x 14.8’ 2 - 1 1 - Notes: 33’ bench Third Floor (Work Station 1) Holding 1978 1 - 5 (5) 8.7’ x 5.5’ 1 - 1 1 - Notes: 4.5’ + 3.3’ bench Fourth Floor (Work Station 1) Holding 1978 1 - 5 (5) 8.7’ x 5.5’ 1 - 1 1 - Notes: 4.5’ + 3.3’ bench Fifth Floor (Work Station 1) Holding 1978 1 - 5 (5) 8.7’ x 5.5’ 1 - 1 1 - Notes: 4.5’ + 3.3’ bench *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit; If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. P:\Adult..\Cycle\Living..\5206 SCSO Hall of Justice LAS.doc; 2/04/2016 - 1 - A360 LAS Adult.dot (9/98) ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S Sixth Floor (Work Station 1) Holding 1978 1 - 5 (5) 8.7’ x 5.5’ 1 - 1 1 - Notes: 4.5’ + 3.3’ bench WORK STATION #2 – basement and 4 floors with holding cells Basement (Work Station 2) – six cells WBH1 Holding 1980 1 - 8 (8) 9.3’ x 12.4’ 1 - 1 1 - Notes: handicap accessible, 9.3’ + 3.6’ bench WBH2 Holding 1980 1 - 8 (8) 9.3’ x 8.4’ 1 - 1 1 - Notes: 12’ bench WBH3 Holding 1980 1 - 16 (16) 19.5’ x 8.6’ 1 - 1 1 - Notes: irregular; 12’ + 15.3’ bench; prior LASE listed RC of (17), changed this cycle to (16) due to holding cell capacity limit and facilities ratio WBH4 Holding 1980 1 - 16 (16) 17.6’ x 9.7’ 1 - 1 1 - Notes: cutout 3.4’ x 4.5’; 11.3’ + 4.8’ + 9’ bench WBH5 Holding 1980 1 - 16 (16) 17.6’ x 10.2’ 1 - 1 1 - Notes: outcropping – subtract 8.5’ from square footage; 16.1’ + 12.7 + 2.8’ bench; prior LASE listed RC as (14), changed to (16) this cycle WBH6 Holding 1980 1 - 16 (16) 17.7’ x 10’ 1 - 1 1 - Notes: 6’ + 10.3 + 4.3’ + 3.8’ bench Third Floor (Work Station 2) – one holding cell Holding 1980 1 - 5 (5) 9.8’ x 8.8’ 1 - 1 1 - Notes: handicap accessible cell; 7.3’ bench and one stool Fourth Floor (Work Station 2) – two holding cells Holding 1980 1 - 5 (5) 8.8’ x 7’ 1 - 1 1 - Notes: irregular shape; 7.3’ bench and one stool; seating limits RC Holding 1980 1 - 5 (5) 8.8’ x 7’ 1 - 1 1 - Notes: irregular shape; 7.3’ bench and one stool; seating limits RC Fifth Floor (Work Station 2) – two holding cells Holding 1980 1 - 5 (5) 8.8’ x 7’ 1 - 1 1 - Notes: irregular shape; 7.3’ bench and one stool; seating limits RC Holding 1980 1 - 5 (5) 8.8’ x 7’ 1 - 1 1 - Notes: irregular shape; 7.3’ bench and one stool; seating limits RC Sixth Floor (Work Station 2) – two holding cells Holding 1980 1 - 5 (5) 8.8’ x 7’ 1 - 1 1 - Notes: irregular shape; 7.3’ bench and one stool; seating limits RC Holding 1980 1 - 5 (5) 8.8’ x 7’ 1 - 1 1 - Notes: irregular shape; 7.3’ bench and one stool; seating limits RC WORK STATION #3 – basement and 5 floors with holding cells Basement (Work Station 3) EBH1 Holding 1980 1 - 8 (8) 9’ x 10.3’ 1 - 1 1 - *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit; If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. P:\Adult..\Cycle\Living..\5206 SCSO Hall of Justice LAS.doc; 2/04/2016 - 2 - A360 LAS Adult.dot (9/98) ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S Notes: 8.9’ + 3.5’ bench EBH2 Holding 1980 1 - 8 (8) 9.8’ x 9’ 1 - 1 1 - Notes: irregular shaped; 8.9’ + 3.1’ bench EBH3 Holding 1980 1 - 16 (16) 19.3’ x 8.6’ 1 - 1 1 - Notes: irregular shaped; used for females; 15’ and 12.6’ bench EBH4 Holding 1980 1 - 16 (16) 17.3’ x 9.3’ 1 - 1 1 - Notes: 9’ + 13.1’ + 4.4’ bench EBH5 Holding 1980 1 - 16 (16) 21.4’ x 10.9’ 1 - 1 1 - Notes: 15.4’ + 11.5’ + 4.1’ + 3.1’ bench EBH6 Holding 1980 1 - 16 (16) 17.3’ x 10’ 1 - 1 1 - Notes: 13.8’ x 8.7’ + 4’ bench Second Floor (Work Station 3) – 4 holding cells and 2 interview rooms (2EI1 and 2EI2) 2EH1 Holding 1980 1 - 2 (2) 7.2’ x 5.5’ 1 - 1 1 - Notes: 2’ bench and one stool 2EH2 Holding 1980 1 - 6 (6) 11.7’ x 8.3’ 1 - 1 1 - Notes: 3.6’ + 6.4’ bench 2EH3 Holding 1980 1 - 5 (5) 11.7’ x 8.3’ 1 - 1 1 - Notes: 4.8’ + 1.5’ bench and one stool 2EH4 Holding 1980 1 - 2 (2) 7.2’ x 5.5’ 1 - 1 1 - Notes: 2’ bench and one stool Third Floor (Work Station 3) – 2 holding cells and 2 interview rooms 3EHC Holding 1980 1 - 4 (4) 8.4’ x 6.9’ 1 - 1 1 - Notes: 5.8’ bench and one stool 3EHD Holding 1980 1 - 3 (3) 8.4’ x 6.9’ 1 - 1 1 - Notes: 5.8’ bench (no stool) Fourth Floor (Work Station 3) – 2 holding cells and 2 interview rooms 4EHC Holding 1980 1 - 4 (4) 8.4’ x 6.9’ 1 - 1 1 - Notes: 5.8’ bench and one stool 4EHD Holding 1980 1 - 4 (4) 8.4’ x 6.9’ 1 - 1 1 - Notes: 5.8’ bench and one stool Fifth Floor (Work Station 3) – 2 holding cells and 2 interview rooms 5EHC Holding 1980 1 - 4 (4) 8.4’ x 6.9’ 1 - 1 1 - Notes: 5.8’ bench and one stool 5EHD Holding 1980 1 - 4 (4) 8.4’ x 6.9’ 1 - 1 1 - Notes: 5.8’ bench and one stool Sixth Floor (Work Station 3) – 2 holding cells and 2 interview rooms 6EHC Holding 1980 1 - 4 (4) 8.4’ x 6.9’ 1 - 1 1 - Notes: 5.8’ bench and one stool 6EHD Holding 1980 1 - 4 (4) 8.4’ x 6.9’ 1 - 1 1 - Notes: 5.8’ bench and one stool *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit; If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. P:\Adult..\Cycle\Living..\5206 SCSO Hall of Justice LAS.doc; 2/04/2016 - 3 - A360 LAS Adult.dot (9/98) *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit; If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. P:\Adult..\Cycle\Living..\5206 SCSO Hall of Justice LAS.doc; 2/04/2016 - 4 - A360 LAS Adult.dot (9/98) ADULT COURT AND TEMPORARY HOLDING FACILITIES PHYSICAL PLANT EVALUATION Board of State and Community Corrections Applicable Title 24 Regulations: 6/94; 2/99; 2001; 2005 BSCC Code: 5208 FACILITY NAME: South County Courthouse FACILITY TYPE: CHJ APPLICABLE REGULATIONS (Check All That Apply): 6/94: 2/99: 2001: X 2005: OTHER: FIELD REPRESENTATIVE: Michael J. Bush DATE: 02/04/2016 TITLE 24 SECTION YES NO N/A COMMENTS Reception and Booking (2.1) Contains a weapons locker, designed as outlined in these X regulations. Contains a cell or room for confinement pending booking X Contains a detoxification cell (WA in TH; NA in CH) 01: Name changed to “sobering cell.” X 2-99: Two detoxification cells are provided if both male and female inmates are held. Contains safety cell(s) (WA in TH; NA in CH) X Shower room available X 2-99: Access to shower must be within the secure area Provides secure vault or storage for inmate valuables X Telephone(s) available for inmate use (PC § 851.5) X 2-99: Unobstructed access to hot and cold running water X Temporary Holding Cell or Room (2.2) X Contains 10 square feet of floor area per inmate Holds no more than 16 inmates X Is not smaller than 40 square feet and has a clear ceiling X height of 8 feet or more Contains sufficient seating to accommodate all inmates X Contains water closet (toilet), washbasin, and drinking X fountain Provides for clear visual supervision by staff X A bunk is provided if inmates are held 12 hours or more X Temporary Staging Cell or Room (2.3) Holds inmates classified and segregated per Title 15 § X 1050 and 1053 Sobering Cell (2.4) 01: Name change to “sobering cell” X Contains 20 square feet of floor area per inmate Safety Cell (2.5) Contains 48 square feet with one floor dimension of a X least 6 feet and a clear ceiling height of 8 feet or more \Adult Jail..\Cycle\Phy..\5208 South County CH PHY.doc; 02/04/2016 - 1 - A382 PHY CH-TH 94 99 01 05.dot (8/05) TITLE 24 SECTION YES NO N/A COMMENTS Safety Equipment Storage (2.19) Adequate space is provided to store equipment such as X fire extinguishers, SCBA, emergency lights, etc. Janitors' Closet (2.20) Lockable, containing a mop sink and storage space X 01: Mop sink may be separate from janitors’ closet Audio or Visual Monitoring (2.22) There is an audio monitoring system capable of alerting staff in a central control. When visual electronic surveillance is use, it is located primarily in corridors, X elevators, or at points on the security perimeter such as entrances and exits. 2-99: Video monitoring option deleted. Emergency Power (2.24) There is an emergency power source available and capable of providing minimal lighting in all areas and X maintaining fire and life safety, security, communication and alarm systems. Attorney Interview Space (2.26) Available and provides for confidentiality X Water Closets (Toilets)/Urinals (3.1) Provide for inmate privacy/modesty with staff being able to visual supervise; provided at a ratio of 1:16 in holding X and staging cells. See regulation for calculations of urinal substitutions. Washbasins (3.2) Provide hot and cold or tempered water; provided at a ratio of 1:16 in holding and staging cells. See regulation X for calculations of washbasin trough substitutions. Drinking Fountains (3.3) 2-99: Available in each temporary holding, staging and X sobering cell. Water outlet (bubbler) is mechanically actuated and at an angle that prevents wastewater from flowing over the outlet (bubbler); there is a mouth guard on the water X outlet (bubbler). 2-99: Mouth guard requirement deleted \Adult Jail..\Cycle\Phy..\5208 South County CH PHY.doc; 02/04/2016 - 2 - A382 PHY CH-TH 94 99 01 05.dot (8/05) TITLE 24 SECTION YES NO N/A COMMENTS Lighting (3.6) Lighting is sufficient to permit easy reading by a person with normal vision, night lighting is sufficient for purposes of supervision. X Lighting is centrally controlled and/or occupant controlled in housing cells or rooms. Light fixtures are of secure design. Windows (3.7) Windows that are accessible to inmates are no greater X than 5 inches in on dimension. Seating (3.10) Seating is designed to the level of security. When bench seating is used, eighteen inches of bench are provided per inmate. X 2-99: In holding and staging cells, seating is securely fastened to the wall and/or floor. Weapons Locker (3.12) A secure weapons locker is located outside the security perimeter of the facility and no weapons are brought into X the security area. Lockers have individual compartments, locks and keys. Design Requirements (102(c)6) Design requirements as specified in Title 24, Part 1, 102(c)6 are met. (See regulation for specific requirements. Note areas of non-compliance that are X applicable to the facility type and construction date in the "comments" section.) \Adult Jail..\Cycle\Phy..\5208 South County CH PHY.doc; 02/04/2016 - 3 - A382 PHY CH-TH 94 99 01 05.dot (8/05) ADULT DETENTION FACILITY LIVING AREA SPACE EVALUATION Board of State and Community Corrections CSA Code: 5208 FACILITY: Santa Clara County South County Morgan Hill Court Holding TYPE: CHJ RC: 0 FIELD REPRESENTATIVE: Michael J. Bush DATE: 03/06/208 ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S BASEMENT 1 Holding 2001 1 (10) (10) 15.6 x 12.0 x 8.1 1 1 1 Bench space – 15. 6 Establishes capacity at 10 inmates (18" per inmate); 2 Holding 2001 1 (1) (6) 9.11 x 10.6 x 9.1 1 1 1 Bench space – 10. 6 Establishes capacity at 6 inmates (18" per inmate); 3 Holding 2001 1 (4) (4) 8.6 x 8.6 x 9.1 1 1 1 Bench space – 71.90 Establishes capacity at 4 inmates (18” per inmate) 4 Holding 2001 1 (5) (5) 10.6 x 8.6 x 9.1 1 1 1 Bench space – 88.9 Establishes capacity at 5 inmates (18” per inmate) 5 Holding 2001 1 (7) (7) 12.9 x 10.2 x 10.1 1 1 1 Bench space 129.38 – Establish capacity at 7 inmates (18” per inmate) ADA Cell 6 Holding 2001 1 (5) (5) 9 x 9.1 x 9.1 1 1 1 Bench space 81.1 – Establishes capacity at 5 (18” per inmate) 7 Holding 2001 1 (5) (5) 10.6 x 8.5 x 9.1 1 1 1 Bench space 90.1 – Establishes capacity at 5 (18” per inmate) 8 Holding 2001 1 (5) (5) 10.6 x 8.3 x 9.1 1 1 1 Bench space 87.98 – Establishes capacity at 5 (18” per inmates) 9 Holding 2001 1 (5) (5) 9.3 x 9.2 x 9.1 1 1 1 Bench space 85.56 – Establishes capacity at 5 (18” per inmate) 10 Holding 2001 1 (5) (5) 10.6 x 9.1 x 9.1 1 1 1 Bench space 96.46 – Establishes capacity at 5 (18” per inmate) 11 Holding 2001 1 (5) (5) 10.6 x 8.4 x 9.1 1 1 1 *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit. If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 5208 SCSO South County CH LAS.doc; 03/06/2018 - 1 - A360 LAS Adult-05.dot (8/05) ROOMS EACH ROOM Cell Applicable # EACH CELL Total DIMENSIONS FIXTURES* Location Type Standards Cells # Beds RC RC (L x W x H) T U W F S Bench space 89.04 – Establishes capacity at 5 (18” per inmate) 12 Holding 2001 1 (5) (5) 10.5 x 8.5 x 9.1 1 1 1 Bench space – 89.25 Establishes capacity at 5 (18” per inmate) 13 Holding 2001 1 (5) (5) 10.6 x 8.9 x 9.1 1 1 1 Bench space 94.34 – Establishes capacity at 5 (18” per inmate) 14 Holding 2001 1 (6) (6) 13.3 x 10.1 x 10.1 1 1 1 Bench space 104.03 – Establishes capacity at 6 (18” per inmate) 15 Holding 2001 1 (6) (6) 13.1 x 10.2 x 10.1 1 1 1 Bench space 103.02 – Establishes capacity at 6 (18” per inmate) 16 Holding 2001 1 (6) (6) 13.1 x 10.2 x 10.1 1 1 Bench space 103.02 – Establishes capacity at 6 (18” per inmate),. This cell is used for minors. 1ST’FLOOR 1 Holding 2001 1 (4) (4) 10.6 x 7.0 x 8.4 1 1 1 Bench space 74.2 – Establishes capacity at 4 (18” per inmate). Adjacent to Department 105. 2 Holding 2001 1 (5) (5) 10.6x 9.0 x 8.4 1 1 1 Bench space 95.4 – Establishers capacity at 5 (18” per inmate). Adjacent to Department 106. 2nd FLOOR 1 Holding 2001 1 (4) (4) 10.6 x 07.0 x 10.1 1 1 1 Bench space 74.2 – Establishes capacity at 4 (18” per inmate). Adjacent to Department 107. 2 Holding 2001 1 (5) (5) 10.6 x 8.1 x 10.1 1 1 1 Bench space 85.86 – Establishes capacity at 5 (18” per inmate). Adjacent to Department 108. 1 Holding 2001 1 (4) (4) 10.3 x 6.2 x 10.1 1 1 1 Bench space 63.83 – Establishes capacity at 4 (18” per inmate). Adjacent to Department 109. Separate elevators provided. 2 Holding 2001 1 (4) (4) 10.4 x 6.2 x 10.1 1 1 1 Bench space 64.48 – Establishes capacity at 4 (18” per inmate). Adjacent to Department 110. Separate elevators provided. *T = Toilets; U = Urinals; W = Wash Basins; F = Fountains; S = Showers in unit. If "Total RC" appears in brackets ( ), it is not part of the facility's rated capacity. "+" indicates that capacity includes prorated air space from adjacent areas. 5208 SCSO South County CH LAS.doc; 03/06/2018 - 2 - A360 LAS Adult-05.dot (8/05)