Liberty Vote IntraScan Root Cause Analysis
Liberty Vote Democracy Suite 5.10A
Read the report at Liberty Vote Systems ↗
ICC WITH HIPRO-H12 SCANNER
Input Hopper Tray Error Message
(ICC Software v. 5.10, Scanner Firmware 1.0.1019)
Certification Testing
ROOT CAUSE ANALYSIS
2020-06-17
Contents Introduction
ImageCast® Central software with a HiPro
Introduction 2
H12 scanner were provided to California
Problem 2
Secretary of State office for certification
Investigation 3
testing in January 2019. As of February 2020,
Solution 4 the Scanner was fully functional during 5.10
and Imprinter Certification
During 5.10A certification effort in June
2020, the scanner was powered on for testing.
Upon initialization scanner displayed error
messages codes 911 and 912. These error
messages were determined to be related to the
Input Hopper Tray motor control unit.
Dominion technician was sent on site and it
was determined that the issue was
intermittent. The technician replaced some
parts in the process of trying to fix the fault.
At the end it was decided to replace the
scanner with a new one in order to save time
and the failed scanner was sent to Dominion
facility for further investigation.
It was determined that the error message is
caused by one of the interconnection cables
between motor control board and main
control unit. Further investigation of cable
revealed an intermittent connection in the
RJ45 connector of the cable.
Problem
It was observed that during initialization, the
HiPro H12 scanner would intermittently
display error message codes 911 and 912. In
some situations, the scanner functioned for
some time before displaying the error
messages.
2
message still appeared after some amount of
Investigation scanning.
The devices that were tested in this
investigation were configured as follows:
• HiPro-H12 (S/N: 0040K26)
o FW v1.0.1019
• ImageCast® Central
o SW v. 5.10A
Dominion engineering team was able to
replicate this Input Hopper Tray error
messages on the same HiPro Scanner using
test scan scenarios. Multiple techniques were
then applied to determine the root cause.
The Input Hopper consists of Left Input Tray
and Right Input Trays. Each one is controlled
by a Stepper Control PCB (Left and Right)
accordingly. All these PCBs communicate As a next step the Motion Control Board,
with the main PCB (Motion Board) through which is the main controller of the Input
an additional Stepper Control PCBs. These Hopper Tray, was replaced. All three original
PCBs communicate with each other through Stepper Control PCBs were installed back on
RJ45 Patch cables. the Scanner to make sure all original
parameters are the same except the Motion
To identify the source of the Error Message
Board. The error message showed up after ten
accurately, each original Stepper Control
minutes of volume scan testing.
PCB was replaced with known good Stepper
Control PCB, test scans were performed and The investigations above proved that all
the error message 911 and 912 still appeared. boards are fully functional. The root cause of
Next, all three Stepper Control PCBs with the error message is now narrowed down to
known good ones and replaced, yet, the error the communication cables. However,
replacement cables could not reach in time
for certification due to shipping difficulty.
Therefore, Dominion decided to replace the
HiPro-H12 (S/N: 0040K26) with a fully
functional HiPro-H12 (S/N: 0030K26).
3
The failing HiPro-H12 (S/N: 0040K26) was Solution
then transferred to Dominion facility for To overcome the issue of the Input Hopper
further investigation. Tray’s error message, the damaged harness
cable was replaced with a new one to correct
InterScan’s and Dominion technician
the communication between the Motion
confirmed that the harness cable which
Control PCB and the Stepper Control PCB.
connects the Stepper Control PCB to the
Motion Control PCB had an intermittent
connection inside the connector.
After replacing the harness cable on the
HiPro-H12, the error message could not be
replicated. 5000 scans were conducted using
11” and 14” ballots.
4