OVSTA
Interscan 821d HiPro Scanner Staff Report
Liberty Vote Democracy Suite 5.2
Read the report at Liberty Vote Systems ↗
A P
LEX ADILLA |SECRETARY OF STATE | STATE OF CALIFORNIA
OFFICE OF VOTING SYSTEMS TECHNOLOGY ASSESSMENT
1500 11th Street | Sacramento, CA 95814 | Tel 916.695-1680 | Fax 916.653.4620 | www.sos.ca.gov
DOMINION VOTING SYSTEMS
Interscan 821D HiPro Scanner
Modification to DemSuite 5.2
Administrative Approval Report
Components:
Interscan 821D HiPro Scanner,
Dell OptiPlex 7040 Workstation,
ImageCast Central Version 5.2.2.7
Staff Administrative Approval Report
Prepared by:
Secretary of State’s Office of
Voting Systems Technology Assessment
May 8, 2018
Table of Contents
I. INTRODUCTION............................................................... 3
II. SUMMARY OF THE SYSTEM......................................... 3
III. TESTING INFORMATION AND RESULTS.................... 4
IV. CONCLUSION............................................................... 13
2 | P a ge
SECRETARY OF STATE’S STAFF REPORT- DOMINION INTERSCAN 821D HIPRO SCANNER
I. INTRODUCTION
1. Scope
This report presents the test results for all phases of the approval testing of the
Dominion Voting Systems (Dominion) modification to the Democracy Suite (DemSuite)
5.2 voting system. This modification is for the addition of the Interscan 821D HiPro
ballot scanner and ImageCast Central (HSS-ICC) software. The purpose of testing is to
test the compliance of the modified voting system with California Voting Systems
Standards, and State and Federal laws. Testing also uncovers other findings, which do
not constitute non-compliance, and those findings are reported to the voting system
vendor to address the issues procedurally. The procedures for mitigating any additional
findings are made to the documentation, specifically the California Use Procedures.
2. Summary of the Application for Administrative Approval
Dominion submitted an application for Administrative Approval of the modification to the
DemSuite 5.2 voting system on October 18, 2017. The modification is comprised of the
addition of the Interscan 821D HiPro scanner, and Dell Optiplex 7040 workstation
running Windows 10 and HSS-ICC software version 5.2.2.7. The HSS-ICC version
5.2.2.7 software is a modified version of the ImageCast Central utility which was
previously approved for use in California with the Canon X10 and Canon G1130
scanners.
In addition to the software, which includes the executable code and the source code for
the amended HSS-ICC, Dominion was required to submit the following:
Technical Documentation for the Interscan 821D HiPro scanner;
All the hardware components to field a working version of the Interscan 821D
HiPro scanner;
Optiplex 7040 Workstation running HSS-ICC software, including all peripheral
devices;
Amended California Use Procedures.
3. Contracting and Consultants
Upon receipt of a complete application, the Secretary of State released a Request for
Proposal (RFP) for assistance with both Source Code and Security and
Telecommunications Review.
Through the formal California contracting process, the Secretary of State awarded a
contract to SLI Compliance (SLI), 4720 Independence Street, Wheat Ridge, Colorado.
II. SUMMARY OF THE SYSTEM
The Dominion DemSuite Interscan 821D HiPro scanner/HSS-ICC system consists of a
3 | P a ge
SECRETARY OF STATE’S STAFF REPORT- DOMINION INTERSCAN 821D HIPRO SCANNER
Interscan 821D HiPro scanner and ImageCast Central workstation, and is used for
processing ballots (such as vote by mail) in a central tabulation configuration. This ballot
counter unit is based on commercial off the shelf (COTS) hardware coupled with custom-
made ballot processing application software. It is used for high-speed centralized
scanning and counting of paper ballots.
III. TESTING INFORMATION AND RESULTS
1. Background
Testing of the modification to the DemSuite 5.2 voting system took place from
November 13, 2017, through May 1, 2018. Testing began with the Functional Testing
Phase, which included Volume Testing, followed by Security/Telecommunications
Testing, and Source Code Review for the modified HSS-ICC software.
2. Functional Test Data and Results
The Functional Test of the modified Dominion DemSuite 5.2 voting system was
conducted by Office of Voting Systems Technology Assessment and Dominion staff at
the Secretary of State’s Office located at 1500 11thStreet, Sacramento, California. The
Functional Test focused on the border connections with the existing system, and testing
of the Interscan 821D HiPro scanner.
The Secretary of State ran the Functional Test as if it were a jurisdiction that just
purchased the modified voting system utilizing the Interscan 821D HiPro scanner.
Testing of the system began with building the HSS-ICC workstation. The HSS-ICC
workstation is a Dell OptiPlex 7040 computer running the modified ImageCast Central
software. This build was started by wiping the Optiplex 7040 computer in order to clean
the existing Dell provided software from the workstation. The wipe was followed by the
installation of the Windows 10 operating system, commercial-off-the-shelf drivers, HSS-
ICC trusted build software, and then continued through the security hardening process.
Upon completion of the installation of the system, it was run through an acceptance and
readiness test to determine that each piece of equipment was functioning properly and
that all networking and permissions were configured correctly.
Functional Testing of the system utilized a Multi Seat Ranked Choice Voting (RCV)
Election utilizing 14 inch ballots printed on 100# card stock, a Presidential General
Election utilizing 14 inch ballots printed on 100# card stock, a Special Recall Election on
22 inch ballots printed on 100# card stock, and several targeted test elections. The
specific election definition databases used in testing were based on a fictitious RCV
Election to elect four candidates consisting of 12 candidates and four write ins, the
Presidential General Election, and the California Statewide Special Recall Election. The
Presidential General and Special Recall Elections were configured using actual data
that was exported from California counties election management systems (EMS) and/or
voting systems.
4 | P a ge
SECRETARY OF STATE’S STAFF REPORT- DOMINION INTERSCAN 821D HIPRO SCANNER
The mock elections were conducted as if the system had just been purchased by a
county. The ImageCast X Ballot Marking Device was utilized to duplicate ballots when
needed. It was discovered that three ballots were damaged in printing, and were
duplicated. The mock elections were conducted in an environment that simulated a
small or medium sized county.
Ranked Choice Voting Election: The RCV Election was conducted utilizing one ballot
style with one contest containing ten ranks of choices for twelve candidates and one
write-in. The ImageCast X Ballot Marking Device was utilized to create five voted
ballots, recreations of five of the original ballots, which were then placed in the deck of
twenty three thousand ballots, replacing the originals. The test deck of 23,000 ballots
was tabulated once for ten rounds of ranked choice voting. Polls were opened in
accordance with California Use Procedures. Results were loaded into the EMS, and a
simulated draw from a hat was utilized to advance through the ten rounds of RCV. In
the test, the threshold was 16. The Interscan 821D HiPro scanner/HSS-ICC/EMS
correctly identified all ten rounds of RCV. The results were tabulated correctly through
ten rounds of RCV. Polls were closed in accordance with California Use Procedures,
including printing all reports. Reports were generated printing contest rankings for each
round of RCV.
The RCV Election was conducted by scanning ballots simultaneously on the Interscan
821D HiPro scanner, the previously certified Canon G1130 scanner, and the previously
certified Canon X10 scanner. OVSTA scanned 16,878 ballots on the Interscan 821D
HiPro scanner, 398 ballots on the Canon G1130 scanner, and 6,111 ballots on the
Canon X10 scanner. Ballots were scanned in batch sizes from one to 1,044, and
approximately 25% of the ballots in the face-up, header first orientation, 25% of the
ballots in the face-up, foot first orientation, 25% in the face-down header first orientation,
and about 25% in the face-down, foot first orientation. At the close of polls, the
electronic files from the HSS-ICCs were brought into the Results-Tally-Reports (RTR)
utility. Ballots containing an exception condition were resolved using adjudication. The
results were matched against the expected results file supplied by Dominion. Finally,
the Official Canvass Summary report and Statement of Votes Cast report were
generated. Additionally, the Secretary of State Statement of Vote (SOV) and
Supplemental Statement of Votes (SSOV) reports were generated.
The ballots utilized for the RCV Election constantly shed small slivers of paper from the
edges. The slivers were approximately ½ inch long or shorter, and the ballots were
badly contaminated with them. The slivers appeared to be a result of improperly
trimming/cutting the ballots at the printer. The large nature of the paper dust caused
repeated read errors on the Interscan 821D HiPro scanner. It was discovered that
fanning the batches, then wiping the edges of the ballots, in conjunction with keeping
the read heads clean on the Interscan 821D HiPro scanner greatly improved
performance.
Special Recall Election: The Special Recall Election was comprised of one ballot style
with one contest containing 155 candidates and one write-in. After replacing the arms
on the Interscan 821D HiPro scanner with longer extensions to accommodate the 22
inch ballots, all ballots were scanned on the Interscan 821D HiPro scanner. Four blank
5 | P a ge
SECRETARY OF STATE’S STAFF REPORT- DOMINION INTERSCAN 821D HIPRO SCANNER
ballots and an incorrect ballot were placed at random in the batch. All incorrect or blank
ballots were identified correctly. The 22 inch ballots scanned without error at a rate of
600 ballots in 6 minutes and 36 seconds. All ballots were tabulated correctly.
Post-election results were consolidated and reported based on upload of results to EMS
from the HSS-ICC and Interscan 821D HiPro scanner. Results included generation of
final reports and verifying canvass including the SOV and SSOV.
Presidential General Election: The Presidential General Election was utilized as a
modified volume test for the Interscan 821D HiPro scanner. The ballots were the same
ones used in the original volume test for the DS 5.2 system, but showed little fatigue.
These ballots were relatively clean, and shed a small amount of dust. Working in a
simulated small to mid-sized county environment, and at a casual pace, we scanned
20,000 ballots in 2 hours and 13 minutes.
Polls were closed in accordance with California Use Procedures. Post-election results
were consolidated and reported based on upload of results to EMS. Results included
generation of final reports including the SOV and SSOV.
Targeted Elections: Several elections were run to target specific areas of the Interscan
821D HiPro scanner and HSS-ICC. The first was a test of 1,000 12 inch ballots on 32#
stock generated from the ImageCast X Ballot Marking Device. The ballots were
scanned in landscape orientation and the system scanned them in 3 minutes and 34
seconds for an estimated hourly rate of 16,822.
The next test was for marginal marks. Ballots were marked manually with a black
Sharpie pen, a yellow highlighter, a red pen, a black pen, and a pencil. Ballots were
marked with X’s, check marks, small dots, lines, and completely filled ovals. The ballot
ovals were marked from 5% filled to 100% filled, as well as completely outside the oval.
The Interscan 821D HiPro scanner was set for “red dropout” because the actual ballot
ovals were red. As a result, the Interscan 821D HiPro scanner did not read the red pen
which was the expected result. The Interscan 821D HiPro scanner read all other
markers without error. In every case, the system sent the images to adjudication when
necessary, and processed all the ballots correctly. The adjudication system
appropriately identified all marks including the highlighter.
The next test simulated an all vote by mail election utilizing ballots from the 2016
Presidential Primary which were machine folded tri-fold ballots. The ballots were
unfolded, flattened manually, and counter bent against the fold twice. Utilizing the two
trays on the Interscan 821D HiPro scanner, ballots were continually loaded in stacks of
approximately 125 ballots in the unused tray while the Interscan 821D HiPro scanner
was scanning ballots from the other tray. The Interscan 821D HiPro scanner
automatically switches from one tray to the other. In this fashion, 2,875 ballots were
scanned, running continuously. One read error was experienced after scanning 1,963
ballots that was mitigated by opening the Interscan 821D HiPro scanner, wiping the
read head with a feather duster, and continuing. No other errors or problems occurred.
6 | P a ge
SECRETARY OF STATE’S STAFF REPORT- DOMINION INTERSCAN 821D HIPRO SCANNER
The final test was a marginal ballot test. These ballots would most likely be duplicated
in a real election. Ballots were folded diagonally, horizontally, and vertically at random.
Just the corners and edges were folded on some ballots. Ballots were folded both
singly, and up to ten ballots together. Two ballots were crumpled and then flattened.
Ballots were loaded into the Interscan 821D HiPro scanner trays with folds going in both
directions. After some initial jams and subsequent calibration changes, the Interscan
821D HiPro scanner read these ballots without error, however the rate of scanning
dropped to a point that would not be acceptable for election purposes. Several pickup
roller problems were experienced when the next ballot to be scanned was loaded with
the folds in a different direction from the previous ballot, and the pickup rollers did not
pull them into the Interscan 821D HiPro scanner. OVSTA recommends that ballots with
this amount of wear and tear be duplicated, or scanned on the X10.
Additional Functional Testing
At Dominion’s request, two additional days of functional testing were performed to
optimize the Interscan 821D HiPro scanner for coated ballots printed on an inkjet
printer. The pickup rollers and separation unit were replaced with rollers better suited for
the glossy paper used in the inkjet printing process, and an extension was added to the
feed tray. These modifications/parts are COTS parts available from Interscan 821D
HiPro scanner. The parts replaced are as follows:
Friction lining Green with Riffles part number e0073053
Pre-input roller – e0083027
Separation roller – e0073142
Separation unit assembly (with backing plate)– f600120a
Ballots from two different counties were used to test the modification. The test ballots
were examined and an expected results file was built. The ballots were scanned and the
results reported and matched against the expected results. The Interscan 821D HiPro
scanner performed as expected.
Functional Test Results
Test results showed that the modified voting system including the Interscan 821D HiPro
scanner performed in a manner consistent with California Voting System Standards and
all test cases were executed successfully and accurately.
Anomalies Identified During Functional Testing
As identified above, one anomaly was identified during Functional Testing:
The Interscan 821D HiPro scanner tended to experience read errors in the RCV
Election. In every case, the read error was mitigated by wiping the inside of the
Interscan 821D HiPro scanner with a duster. The provided ballots were cut in a
way that generated a great deal of small slivers of paper that coated not only the
inside of the Interscan 821D HiPro scanner, but the table the ballots were resting
7 | P a ge
SECRETARY OF STATE’S STAFF REPORT- DOMINION INTERSCAN 821D HIPRO SCANNER
on, and the operators using the Interscan 821D HiPro scanner. The amount of
ballot dust from the printing process should be carefully monitored for ballots
tabulated on this Interscan 821D HiPro scanner. Excessive ballot dust may slow
the scanning process for the Interscan 821D HiPro scanner.
3. Accessibility Testing
The Interscan 821D HiPro scanner, while not a voter usable device, includes the ability
to lower and raise in order to accommodate an elections office worker.
It was found that the Interscan 821D HiPro scanner is easily adaptable for sitting or
standing elections workers. It was determined that the technologies implemented for
accessibility and usability in the Interscan 821D HiPro scanner improved the experience
for election workers that may be required to spend hours at a time operating the
Interscan 821D HiPro scanner.
4. Security and Telecommunications Review
The Secretary of State contracted with SLI in Denver, Colorado to conduct the Security
and Telecommunications Review. The Security Review took place at SLI’s office
between February and March, 2018.
Security and Telecommunications testing covered:
Top-level system design and architecture.
System documentation and procedures.
Testing of relevant software and operating system configuration for pertinent
vulnerabilities.
Testing of hardware, including examination of unused hardware ports and
security measures applied to those ports.
Testing of system communications, including encryption of data as well as
protocols and procedures for access authorization.
The testing was divided into three phases:
Phase I included review of all pertinent documents for appropriate processes and
8 | P a ge
SECRETARY OF STATE’S STAFF REPORT- DOMINION INTERSCAN 821D HIPRO SCANNER
procedures for implementing a secure system. This included a review of the system
design and architecture.
Phase II included testing of relevant software, operating systems, and hardware
configurations.
Phase Ill included testing of all telecommunications aspects of the system.
Phase I
During Phase I testing, review of the TDP validated that all requirements have been
met.
Phase II
It was determined that because the Interscan 821D HiPro scanner/ HSS-ICC is a central
count location implementation, several of the requirements were not applicable. The
Interscan 821D HiPro scanner does not provide monitoring of physical security,
however, as a central count implementation isolated from outside access, physical
security of the Interscan 821D HiPro scanner would be mitigated procedurally by the
jurisdiction implementing the device.
The Interscan 821D HiPro scanner currently acts as a USB 3.0 connected scanning
device, which is not currently configured with access controls. The HSS-ICC system
controls the Interscan 821D HiPro scanner via the direct attached USB connection.
The HSS-ICC system contains required access control identification measures. The
Interscan 821D HiPro scanner utilizes a Linux-based operating system that contains
usernames and passwords that could be accessed in particular conditions. If properly
configured, the Linux-based access controls would meet the requirements. The HSS-
ICC computer runs on the Windows Operating System, which provides access control
as expected.
Additionally, any auditing in relation to election results or ballots are produced from the
HSS-ICC that is connected to the Interscan 821D HiPro scanner. The capability for
logging is available on the Interscan 821D HiPro scanner but only for issues related to
the Interscan 821D HiPro scanner itself. It is determined that the Interscan 821D HiPro
scanner, being a commercial off the shelf (COTS) device, is functioning as intended.
All physical ports on the Interscan 821D HiPro scanner are accessible and not
physically protected. This includes: one RS232 port, three audio 3.5mm jacks, three
USB 2 ports, one USB 3.0, one HDMI port, and one RJ45 network port. It was
discovered that the RJ45 network jack was not disabled and once the device was
assigned a dynamic IP address from a Dynamic Host Configuration Protocol (DHCP)
server, the network capability was fully functional. Once the device was connected to
the network, Nessus Vulnerability scans were conducted against both the HSS-ICC
scan system and the Interscan 821D HiPro scanner. It was determined during the
vulnerability scan that there is an unencrypted Telnet server being served on TCP port
23. This server allows access to the Interscan 821D HiPro scanner operating system.
Upon further investigation it was determined that the root account on the Interscan
9 | P a ge
SECRETARY OF STATE’S STAFF REPORT- DOMINION INTERSCAN 821D HIPRO SCANNER
821D HiPro scanner was unprotected by password and root access to the Interscan
821D HiPro scanner was achieved. While the Interscan 821D HiPro scanner isn't
currently configured for network batch transmission, the Interscan 821D HiPro scanner
is accessible. This could potentially lead to compromise of the Interscan 821D HiPro
scanner and or access to scanned ballot images. Completion of the Nessus
Vulnerability scan determined no further vulnerabilities associated with the Interscan
821D HiPro scanner.
Vulnerabilities were referred to Dominion Voting Systems for mitigation, and they
provided the following response:
The Interscan 821D HiPro scanner is a COTS device provided by a third
party vendor and utilizes software, firmware, and hardware that are not
accessible to Dominion Voting Systems for modification. The Interscan
821D HiPro scanner itself solely provides ballot images to the HSS-ICC
application and does not perform any tabulation functions. This
vulnerability can be mitigated by applying adhesive tamper-evident seals
over the RJ45 Ethernet ports or any other unused ports as they are not
required by the HSS-ICC system as part of the tabulator configuration.
Additionally, Dominion has requested that the COTS supplier address
these shortcomings of their hardware and firmware and we will seek
approval for an updated version of the Interscan 821D HiPro scanner
when the vendor provides a revised version.
Nessus® Vulnerability scans were conducted on all equipment that were connected to
the private EMS network including the HSS-ICC system. Operating system level
transmissions provided appropriate encryption, receipt validation, and data integrity.
Protection against malware on the HSS-ICC computer is provided by the AVAST
Antivirus File Shield. The real time anti-virus monitor was only able to detect and clean
one of the four European Institute for Computer Antivirus Research (EICAR) files, which
potentially leaves the system open to zipped and double zipped viruses as well as
infection strings in plain text.
Vulnerabilities were referred to Dominion Voting Systems for mitigation, and they
provided the following response:
The HSS-ICC system specifies the use of Windows Defender with the
latest virus definitions in its system documentation. Additionally, CA
conditions of use for the DemSuite 5.2 system certification require that an
“air gap” be maintained between the central count system and public
networks and that all removable media introduced to the system first be
formatted and scanned utilizing a dedicated and physically
separate/disconnected workstation specifically configured solely for this
purpose.
The system was tested to verify that the installation process for each system component
is robust and maintains the integrity of the voting system. It was discovered that
Dominion specifies what is required to complete software validation but does not
10 | P a ge
SECRETARY OF STATE’S STAFF REPORT- DOMINION INTERSCAN 821D HIPRO SCANNER
specifically supply the required software or hardware to do so. SLI was able to replace
digitally signed application installers with renamed executables without the installation
package failing. SLI was able to modify election specific installers utilizing a hex editor
to change minor things including mouse over text and digital signature names. SLI was
able to take installers from previous versions of the installation package and use them to
install older versions of the software from the DemSuite Installation. SLI believes it
would be possible to inject more lethal payloads into the installers given the opportunity.
Further, it was discovered that system logs did not provide entries that dealt with a failed
or successful installation of software.
Vulnerabilities were referred to Dominion Voting Systems for mitigation, and they
provided the following response:
Dominion specifies that third-party software be downloaded from a trusted
source in order to verify the installed software hashes. It is Dominion’s
belief that utilizing third-party software improves the proof that the hashes
are genuine and that using a vendor-supplied tool would essentially result
in a self-check of little value to end users of the product. Additionally, the
HSS-ICC system specifies hash validation of installed software and does
not provide verification methods prior to software installation.
Telecommunications data integrity was determined to be not applicable. Individual
public facing voting components are not networked nor do they transmit individual
voting results. The only telecommunications that are in use are an isolated closed
network to link the EMS/Adjudication/HSS-ICC devices together at a central count
location. This requirement is also not applicable to the Interscan 821D HiPro scanner.
Phase III
It was determined that while the Interscan 821D HiPro scanner does have network
capabilities there are no wireless transmission devices present.
5. Source Code Review
Source Code Review was conducted at SLI in Denver, Colorado between February and
March, 2018.
The source code was delivered to SLI by Dominion Voting Systems prior to testing
starting. The modified DemSuite 5.2 system required testing of 5,129 new lines of code
and 9,246 lines of modified code for the HSS-ICC /Interscan 821D HiPro scanner.
Three potential vulnerabilities were found within the HSS-ICC source code base:
One potential vulnerability was noted when the HSS-ICC source code was analyzed for
its ability to appropriately accommodate error and exception handling.
11 | P a ge
SECRETARY OF STATE’S STAFF REPORT- DOMINION INTERSCAN 821D HIPRO SCANNER
Vulnerabilities were referred to Dominion Voting Systems for mitigation, and they
provided the following response:
As noted by the reviewer, exploitation of this vulnerability would require
access by a vendor insider with extensive knowledge of the voting
technology design and configuration. As a central scan product typically
used in a secure central office with controlled access, the ability of a
vendor insider-initiated attack is extremely remote. Exception handling
issues generally result in application lockups or crashes rather than
exposing potential security attack vectors. No unhandled exception states
in the HSS-ICC application were noted during functional and operational
testing.
One potential vulnerability was noted when the HSS-ICC source code was evaluated for
the likelihood of security failures being detected, and whether data that might be subject
to tampering is properly validated and authenticated.
Vulnerabilities were referred to Dominion Voting Systems for mitigation, and they
provided the following response:
As noted by the reviewer, exploitation of this vulnerability would require
access by a vendor insider with extensive knowledge of the voting
technology design and configuration. As a central scan product typically
used in a secure central office with controlled access, the ability of a
vendor insider-initiated attack is extremely remote. Data passed between
functions within the system is generally not able to be manipulated in an
exploitable way without modification of the application's source code.
One potential vulnerability was noted when the HSS-ICC source code was evaluated
for design and implementation to ensure that sound, generally accepted
engineering practices are followed, checking to verify that code is defensively
written against bad data, errors in other modules, changes in environment, user
errors, and other adverse conditions. Exploitation of the vulnerability would require
access by a Vendor Insider with extensive knowledge of the voting technology design
and configuration.
Vulnerabilities were referred to Dominion Voting Systems for mitigation, and they
provided the following response:
As noted by the reviewer, exploitation of this vulnerability would require
access by a vendor insider with extensive knowledge of the voting
technology design and configuration. As a central scan product typically
used in a secure central office with controlled access, the ability of a
vendor insider-initiated attack is extremely remote. Defensive coding
practices are generally used to enhance application stability and are not
12 | P a ge
SECRETARY OF STATE’S STAFF REPORT- DOMINION INTERSCAN 821D HIPRO SCANNER
typically exploitable as security vulnerabilities. In this instance, we believe
the reviewer is noting the same discrepancy described above related to
data passed internally within the application. No application stability issues
were noted during functional and operational testing.
IV. CONCLUSION
The modification to the Dominion DemSuite 5.2 voting system, in the configuration
tested and documented by the Installation and Use Procedures, does not impair its
accuracy and efficiency.
Should the modification be approved, it is recommended that the unsecured network
port, as well as any unsecured ports on the Interscan 821D HiPro scanner be covered
by a seal or a permanent metal cover.
Additionally, it is recommended that the Interscan 821D HiPro Linux-based access
controls be properly configured to meet the requirements.
13 | P a ge
SECRETARY OF STATE’S STAFF REPORT- DOMINION INTERSCAN 821D HIPRO SCANNER